Long range standoff detection of chemical and explosive hazards on surfaces

Fielded surface detection systems rely on contact with either the liquid contamination itself or the associated chemical vapor above the contaminated surface and do not provide a standoff or remote detection capability. Conversely, standoff chemical vapor sensing techniques have not shown efficacy in detecting those contaminants as liquids or solids on surfaces. There are a number of optical or spectroscopic techniques that could be applied to this problem of standoff chemical detection on surfaces. The three techniques that have received the most interest and development are laser induced breakdown spectroscopy (LIBS), fluorescence, and Raman spectroscopy. Details will be presented on the development of these techniques and their applicability to detecting CBRNE contamination on surfaces.

[1]  Sanford A. Asher,et al.  UV resonance Raman excitation profile through the 1B2u state of benzene , 1985 .

[2]  Chris Dyer,et al.  Standoff liquid CW detection , 2004, SPIE Optics East.

[3]  J.L.N. Harteveld,et al.  Studies on a surface acoustic wave (SAW) dosimeter sensor for organophosphorous nerve agents , 1997 .

[4]  C A Boulet,et al.  Indirect laser-induced fluorescence detection for capillary electrophoresis using a violet diode laser. , 2001, Analytical chemistry.

[5]  P. Jurs,et al.  Detection of hazardous vapors including mixtures using pattern recognition analysis of responses from surface acoustic wave devices. , 1988, Analytical chemistry.

[6]  Arthur J. Sedlacek,et al.  Ultraviolet mini-Raman lidar for stand-off, in situ identification of chemical surface contaminants , 2000 .

[7]  Mikko Utriainen,et al.  Combining miniaturized ion mobility spectrometer and metal oxide gas sensor for the fast detection of toxic chemical vapors , 2003 .

[8]  P. Buvat,et al.  Detection of degradation products of chemical warfare agents by highly porous molecularly imprinted microspheres. , 2008, The Analyst.

[9]  Ramasamy Manoharan,et al.  UV Resonance Raman Studies of Bacteria , 1992 .

[10]  Gregory P. Harmer,et al.  Detection of chemical warfare agents using nanostructured metal oxide sensors , 2005 .

[11]  Dudley H. Williams,et al.  Rapid identification of nerve agents Sarin (GB) and Soman (GD) with the use of a field‐portable GC/SAW vapor detector and liquid desorption front‐end device , 1999 .

[12]  Eldon Puckrin,et al.  Passive standoff detection of chemical warfare agents on surfaces. , 2004, Applied optics.

[13]  David R Walt,et al.  Microbead chemical switches: an approach to detection of reactive organophosphate chemical warfare agent vapors. , 2006, Journal of the American Chemical Society.

[14]  H. Hill,et al.  Conventional analytical methods for chemical warfare agents , 2002 .

[15]  Christoph Weder,et al.  Fluorescent sensors for the detection of chemical warfare agents. , 2007, Chemistry.

[16]  Steven D. Christesen,et al.  Application of UV-Raman spectroscopy to the detection of chemical and biological threats , 2004, SPIE Optics East.

[17]  T. Swager,et al.  Fluorescent detection of chemical warfare agents: functional group specific ratiometric chemosensors. , 2003, Journal of the American Chemical Society.

[18]  Todd E. Mlsna,et al.  Chemicapacitive microsensors for volatile organic compound detection , 2003 .

[19]  K. H. Fung,et al.  Stand-off Detection of Chemicals by UV Raman Spectroscopy , 2000 .

[20]  Vasanthi Sivaprakasam,et al.  Multiple UV wavelength excitation and fluorescence of bioaerosols , 2004, SPIE Optics East.

[21]  N S Lewis,et al.  Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors for the nerve agent simulants dimethylmethylphosphonate and diisopropylmethylphosponate. , 2001, Analytical chemistry.

[22]  Yasuo Seto,et al.  Sensing technology for chemical-warfare agents and its evaluation using authentic agents , 2005 .

[23]  D. Huxley UV RAMAN SPECTROSCOPY , 1999 .

[24]  H. Hill,et al.  Surface detection of chemical warfare agent simulants and degradation products , 2005 .

[25]  William F. Hug,et al.  New 224 nm Hollow Cathode Laser-UV Raman Spectrometer , 2001 .

[26]  Peter L. Holland,et al.  Infrared Differential Absorption Lidar for Vapor Detection , 1988 .

[27]  S. Asher,et al.  Raman spectroscopy of a coal liquid shows that fluorescence interference is minimized with ultraviolet excitation. , 1984, Science.

[28]  Eldon Puckrin,et al.  Military Application of Differential FTIR Radiometry for Passive Standoff Detection , 2005 .

[29]  William F. Hug,et al.  Status of miniature integrated UV resonance fluorescence and Raman sensors for detection and identification of biochemical warfare agents , 2005, SPIE Optics East.

[30]  R. Bhartia,et al.  Biochemical detection and identification false alarm rate dependence on wavelength using laser induced native fluorescence , 2006, SPIE Defense + Commercial Sensing.

[31]  N. S. Higdon,et al.  Expanding applications for surface-contaminant sensing using the laser interrogation of surface agents (LISA) technique , 2004, SPIE Optics East.

[32]  Mel Spence,et al.  Multivariate data analysis of fluorescence signals from biological aerosols , 2001 .