A system for nonradiographic source localization and real-time planning of intraoperative high dose rate brachytherapy.

We have developed a system for source localization and real-time planning of interstitial volume implants for intraoperative radiation therapy (IORT) using high dose rate remote afterloading techniques. Source localization is realized by using an electromagnetic tracking device, which consists of a transmitter coil, a receiver coil, and a signal processing unit, to generate the coordinates and orientation of the receiver. A drawback of the device is its sensitivity to adjacent metallic objects. Localization accuracy was evaluated in an operating room environment, where the metallic objects closest to the receiver are surgical retractors (that, incidentally, preclude radiographic localization). For achievable separation distances, we found an rms error of 0.7 mm in determining the distance between points 2 cm apart, thereby demonstrating the feasibility of the method. The receiver is mounted on a plastic block from which projects a long stylet and the transmitter is located at about 50 cm from the receiver. The stylet is inserted sequentially into source catheters to obtain the location and orientation data that serve as input to treatment planning software. The planning program optimizes source dwell time to make calculated dose conform to the dose prescribed on an ellipsoidal surface to an extent consistent with a certain level of dose uniformity inside the target volume. A least squares method is used that involves minimizing the objective function by a matrix method (nonnegative least squares). We have demonstrated that dwell time optimization can be performed in a short time and that the approach is adequate for the IORT application.

[1]  L L Anderson,et al.  Treatment of liver metastases from colorectal cancer with radioactive implants , 1994, Cancer.

[2]  R. Maciunas,et al.  Interactive image-guided neurosurgery , 1992, IEEE Transactions on Biomedical Engineering.

[3]  L L Anderson,et al.  Treatment of primary unresectable carcinoma of the pancreas with I-125 implantation. , 1989, International journal of radiation oncology, biology, physics.

[4]  U F Rosenow,et al.  Clinical implementation of stereotaxic brain implant optimization. , 1991, Medical physics.

[5]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[6]  Roy Kalawsky,et al.  The science of virtual reality and virtual environments - a technical, scientific and engineering reference on virtual environments , 1993 .

[7]  F. Vicini,et al.  Concurrent treatment planning for outpatient high dose rate prostate template implants. , 1993, International journal of radiation oncology, biology, physics.

[8]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[9]  W Schlegel,et al.  Computerized optimization of 125I implants in brain tumors. , 1988, International journal of radiation oncology, biology, physics.

[10]  E. Sternick,et al.  A dose homogeneity index for evaluating 192Ir interstitial breast implants. , 1988, Medical physics.

[11]  Dietrich Meyer-Ebrecht,et al.  An Optical Navigator for Brain Surgery , 1996, Computer.

[12]  G H Barnett,et al.  Intraoperative localization using an armless, frameless stereotactic wand. Technical note. , 1993, Journal of neurosurgery.

[13]  L L Anderson,et al.  A "natural" volume-dose histogram for brachytherapy. , 1986, Medical physics.