Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT.

Purpose To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images. Materials and Methods This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted κ analysis. Results Ninety patients were included (mean age, 80 years ± 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (κ = 0.974) and on VNC images at 70 keV for CAC (κ = 0.967). Conclusion VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.Keywords: Coronary Arteries, Aortic Valve, Mitral Valve, Aortic Stenosis, Calcifications, Photon-counting Detector CT Supplemental material is available for this article © RSNA, 2023.

[1]  M. Greuter,et al.  Coronary calcium scores on dual-source photon-counting computed tomography: an adapted Agatston methodology aimed at radiation dose reduction , 2022, European Radiology.

[2]  L. Boussel,et al.  Coronary CT Angiography with Photon-counting CT: First-In-Human Results. , 2022, Radiology.

[3]  M. Greuter,et al.  Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study , 2022, The International Journal of Cardiovascular Imaging.

[4]  Jayasai R. Rajagopal,et al.  Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT. , 2021, Radiology. Cardiothoracic imaging.

[5]  H. Alkadhi,et al.  Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT—First Evidence from Phantom and In-Vivo Scans , 2021, Diagnostics.

[6]  H. Alkadhi,et al.  Incremental Prognostic Value of Coronary Artery Calcium Score for Predicting All-Cause Mortality after Transcatheter Aortic Valve Replacement. , 2021, Radiology.

[7]  K. Laugwitz,et al.  Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective , 2021, European Radiology.

[8]  J. Moon,et al.  Prevalence and Outcomes of Concomitant Aortic Stenosis and Cardiac Amyloidosis , 2020, Journal of the American College of Cardiology.

[9]  T. Flohr,et al.  Photon-counting CT review. , 2020, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  A. Huber,et al.  Clinical impact of mitral calcium volume in patients undergoing transcatheter aortic valve implantation. , 2020, Journal of cardiovascular computed tomography.

[11]  S. Leng,et al.  Update on Multienergy CT: Physics, Principles, and Applications. , 2020, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  E. Klotz,et al.  Identifying Cardiac Amyloid in Aortic Stenosis , 2020, JACC. Cardiovascular imaging.

[13]  Nishant R. Shah,et al.  Aortic valve calcification predicts all-cause mortality independent of coronary calcification and severe stenosis. , 2020, Atherosclerosis.

[14]  H. Alkadhi,et al.  Aortic valve calcification scoring with computed tomography: impact of iterative reconstruction techniques , 2020, The International Journal of Cardiovascular Imaging.

[15]  S. Piechnik,et al.  Extracellular Myocardial Volume in Patients With Aortic Stenosis , 2020, Journal of the American College of Cardiology.

[16]  Ernst J Rummeny,et al.  Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data , 2018, PloS one.

[17]  M. Budoff,et al.  Calcification of the heart: mechanisms and therapeutic avenues , 2018, Expert review of cardiovascular therapy.

[18]  M. Budoff,et al.  CAC-DRS: Coronary Artery Calcium Data and Reporting System. An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT). , 2018, Journal of cardiovascular computed tomography.

[19]  Jeroen J. Bax,et al.  2017 ESC/EACTS Guidelines for the management of valvular heart disease. , 2017, European heart journal.

[20]  Julian L Wichmann,et al.  Correction Factors for CT Coronary Artery Calcium Scoring Using Advanced Modeled Iterative Reconstruction Instead of Filtered Back Projection. , 2016, Academic radiology.

[21]  J. Leipsic,et al.  SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee: Endorsed by the North American Society for Cardiovascular Imaging (NASCI). , 2016, Journal of cardiovascular computed tomography.

[22]  M. Chung,et al.  Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring , 2016, Korean journal of radiology.

[23]  Takayuki Abe,et al.  Feasibility of coronary artery calcium scoring on virtual unenhanced images derived from single-source fast kVp-switching dual-energy coronary CT angiography. , 2014, Journal of cardiovascular computed tomography.

[24]  Florian Schwarz,et al.  Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography. , 2012, Radiology.

[25]  Klaus Mann,et al.  Coronary risk stratification, discrimination, and reclassification improvement based on quantification of subclinical coronary atherosclerosis: the Heinz Nixdorf Recall study. , 2010, Journal of the American College of Cardiology.