First Performance Results of Ce:GAGG Scintillation Crystals With Silicon Photomultipliers

A new single-crystal Cerium doped Gd<sub>3</sub>Al<sub>2</sub>Ga<sub>3</sub> O<sub>123</sub>Al<sub>2</sub>Ga<sub>3</sub> O<sub>12</sub> (GAGG) scintillation crystal with high luminosity, high density and relatively fast decay time has successfully been grown. We report on the first performance results of the new GAGG scintillation crystal read out with silicon photomultipliers (SiPM) from Hamamatsu (MPPC) and FBK. The best energy resolution (511 keV peak of Ge-68) of 7.9% was attained with GAGG coupled to MPPC and 9.0% with the FBK SiPM after correcting for non-linearity. On the other hand, the best coincidence resolving time (FWHM) of polished 3 × 3 × 5 mm<sup>3</sup> and 3 × 3 × 20mm<sup>3</sup>crystals were 464 ±12 ps and 577 ±22 ps for GAGG crystals compared to 179 ±8 ps and 214 ±6 ps for LYSO crystals respectively with MPPCs. The rise time of GAGG was measured to be 200 ps (75%) and 6 ns (25%) while the decay time was 140 ns (92%), 500 ns (7.7%) 6000 ns (0.3%).

[1]  Stefano Buono,et al.  Silicon photomultipliers and their bio-medical applications , 2007 .

[2]  F. Beekman,et al.  A Comprehensive Model of the Response of Silicon Photomultipliers , 2010, IEEE Transactions on Nuclear Science.

[3]  M. Albrow,et al.  Electro-Optical Performances of p-on-n and n-on-p Silicon Photomultipliers , 2012, IEEE Transactions on Electron Devices.

[4]  Gin-Chung Wang Timing Optimization of Solid-State Photomultiplier Based PET Detectors , 2010, IEEE Transactions on Nuclear Science.

[5]  A. Del Guerra,et al.  Preliminary study of silicon photomultipliers for space missions , 2007 .

[6]  W. Moses,et al.  Prospects for time-of-flight PET using LSO scintillator , 1999 .

[7]  William W. Moses,et al.  Scintillator requirements for medical imaging , 1999 .

[8]  Owen B. Drury,et al.  Transparent ceramic scintillator fabrication, properties, and applications , 2008, Optical Engineering + Applications.

[9]  J. D. Powell,et al.  Design and Implementation of a Facility for Discovering New Scintillator Materials , 2008, IEEE Transactions on Nuclear Science.

[10]  R. Mirzoyan,et al.  A test of silicon photomultipliers as readout for PET , 2005 .

[11]  R. Hawrami,et al.  Comparative gamma spectroscopy with SrI2(Eu), GYGAG(Ce) and Bi-loaded plastic scintillators , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[12]  S. Shimizu,et al.  Scintillation Properties of Lu Gd SiO :Ce (LGSO) Crystal , 2006 .

[13]  H. Suzuki,et al.  The role of gadolinium in the scintillation processes of cerium-doped gadolinium oxyorthosilicate , 1994 .

[14]  G. E. Thomas,et al.  Measurement of the Time Dependence of Scintillation Intensity by a Delayed‐Coincidence Method , 1961 .

[15]  D. Renker Geiger-mode avalanche photodiodes, history, properties and problems , 2006 .

[16]  H. Saunders,et al.  Signal Recovery from Noise in Electronic Instrumentation , 1985 .

[17]  C. Piemonte,et al.  The DLED Algorithm for Timing Measurements on Large Area SiPMs Coupled to Scintillators , 2012, IEEE Transactions on Nuclear Science.

[18]  C. Melcher,et al.  Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[19]  M. Moszynski,et al.  Timing properties of GSO, LSO and other Ce doped scintillators , 1996 .

[20]  D. Renker New developments on photosensors for particle physics , 2009 .

[21]  J. Karp,et al.  Timing and energy characteristics of LaBr3[Ce] and CeBr3 scintillators read by FBK SiPMs , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[22]  C. Melcher Perspectives on the future development of new scintillators , 2005 .

[23]  W. Moses,et al.  Design of a pulsed X-ray system for fluorescent lifetime measurements with a timing accuracy of 109 PS , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[24]  R. Muenchausen,et al.  Crystal growth and optical characterization of cerium-doped Lu1.8Y0.2SiO5 , 2000 .

[25]  C. V. van Eijk,et al.  Radiation detector developments in medical applications: inorganic scintillators in positron emission tomography. , 2008, Radiation protection dosimetry.

[26]  Martin Nikl,et al.  2 inch diameter single crystal growth and scintillation properties of Ce:Gd3Al2Ga3O12 , 2012 .

[27]  C. Levin,et al.  Development of an Ultrahigh Resolution Block Detector Based on 0.4 mm Pixel Ce:GAGG Scintillators and a Silicon Photomultiplier Array , 2013, IEEE Transactions on Nuclear Science.

[28]  Nepomuk Otte,et al.  The Silicon Photomultiplier - A new device for High Energy Physics, Astroparticle Physics, Industrial and Medical Applications , 2006 .

[29]  S. Shimizu,et al.  Scintillation Properties of Lu$_0.4$Gd$_1.6$SiO$_5$:Ce (LGSO) Crystal , 2006, IEEE Transactions on Nuclear Science.

[30]  C. Levin,et al.  Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation , 2011, Physics in medicine and biology.