The initial stability of uncemented acetabular components.

The osseo-integration of an uncemented acetabular component depends on its initial stability. This is usually provided by under-reaming of the acetabulum. We have assessed the fixation of 52 mm porous-coated hemispherical prostheses inserted into cadaveric acetabula under-reamed by 1, 2, 3 and 4 mm. We tested the torsional stability of fixation, after preloading with 686 N in compression, by measuring the torque required to produce 1 degree and 2 degrees of rotation. Under-reaming by 2 mm and 3 mm gave significantly better fixation than 1 mm (p less than 0.01, p less than 0.02). Insertion after under-reaming of 4 mm caused some fractures. To obtain maximum interference fit and optimal implant stability, we recommend the use of an implant 2 mm or 3 mm larger than the last reamer.

[1]  R. Jinnah,et al.  Evaluation of acetabular stability in uncemented prostheses. , 1991, The Journal of arthroplasty.

[2]  M. Saleh,et al.  Femoral neck fracture fixation. Comparison of a sliding screw with lag screws. , 1990, The Journal of bone and joint surgery. British volume.

[3]  M. Ritter,et al.  Structures at risk from medially placed acetabular screws. , 1990, The Journal of bone and joint surgery. American volume.

[4]  H Bereiter,et al.  Cementless press-fit cup. Principles, experimental data, and three-year follow-up study. , 1989, Clinical orthopaedics and related research.

[5]  P. Lachiewicz,et al.  In vitro initial fixation of porous-coated acetabular total hip components. A biomechanical comparative study. , 1989, The Journal of arthroplasty.

[6]  J. Chae,et al.  Macroscopic and microscopic evidence of prosthetic fixation with porous-coated materials. , 1988, Clinical orthopaedics and related research.

[7]  J. Galante,et al.  Results of cementless revisions of total hip arthroplasties using the Harris-Galante prosthesis. , 1988, Clinical orthopaedics and related research.

[8]  R. Barrack,et al.  Quantitative analysis of tissue growth into human porous total hip components. , 1988, The Journal of arthroplasty.

[9]  S. Larsson,et al.  Fixation of trochanteric hip fractures. A cadaver study of static and dynamic loading. , 1987, Acta orthopaedica Scandinavica.

[10]  J. M. Lee,et al.  Observations on the Effect of Movement on Bone Ingrowth into Porous‐Surfaced Implants , 1986, Clinical orthopaedics and related research.

[11]  H. Hansson,et al.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. , 1981, Acta orthopaedica Scandinavica.

[12]  Rahn Ba,et al.  Biomechanics of fracture healing. , 1980 .

[13]  P. Ducheyne,et al.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants. , 1977, Journal of biomedical materials research.

[14]  S. Simon,et al.  "Stiction-friction" of total hip prostheses and its relationship to loosening. , 1975, The Journal of bone and joint surgery. American volume.

[15]  R M Pilliar,et al.  The effect of movement on the bonding of porous metal to bone. , 1973, Journal of biomedical materials research.

[16]  G. Andersson,et al.  Loosening of the cemented acetabular cup in total hip replacement. , 1972, The Journal of bone and joint surgery. British volume.

[17]  W. Enneking,et al.  Biomechanical properties of paired canine fibulas. , 1972, Journal of biomechanics.

[18]  N. Rydell Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons. , 1966, Acta orthopaedica Scandinavica.