Mitigation of distorted and unbalanced stator voltage of stand-alone doubly fed induction generators using repetitive control technique

Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.

[1]  F. Blaabjerg,et al.  Flicker study on variable speed wind turbines with doubly fed induction generators , 2005, IEEE Transactions on Energy Conversion.

[2]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[3]  Hong-Hee Lee,et al.  Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems , 2011 .

[4]  Barry W. Williams,et al.  Improved Control of DFIG Systems During Network Unbalance Using PI–R Current Regulators , 2009, IEEE Transactions on Industrial Electronics.

[5]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[6]  G.R. Slemon,et al.  Modelling of inductance machines for electric drives , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[7]  Siew-Chong Tan,et al.  Analysis and design of repetitive controller for harmonic elimination in PWM voltage source inverter systems , 2008 .

[8]  Bin Zhang,et al.  Linear Phase Lead Compensation Repetitive Control of a CVCF PWM Inverter , 2008, IEEE Transactions on Industrial Electronics.

[9]  Hong-Hee Lee,et al.  Control Strategy for Harmonic Elimination in Stand-Alone DFIG Applications With Nonlinear Loads , 2011, IEEE Transactions on Power Electronics.

[10]  N. Kumaresan,et al.  Operation and closed-loop control of wind-driven stand-alone doubly fed induction enerators using a single inverter-battery system , 2012 .

[11]  Hong-Hee Lee,et al.  Stationary frame control scheme for a stand-alone doubly fed induction generator system with effective harmonic voltages rejection , 2011 .

[12]  Huijun Gao,et al.  Distributed H∞ Filtering for a Class of Markovian Jump Nonlinear Time-Delay Systems Over Lossy Sensor Networks , 2013, IEEE Transactions on Industrial Electronics.

[13]  Xiaozhong Liao,et al.  Analysis of a hybrid controlled three-phase grid-connected inverter with harmonics compensation in synchronous reference frame , 2011 .

[14]  Walmir Freitas,et al.  Three-phase doubly fed induction generators: an overview , 2010 .

[15]  Hong-Hee Lee,et al.  Performance Enhancement of Stand-Alone DFIG Systems With Control of Rotor and Load Side Converters Using Resonant Controllers , 2012, IEEE Transactions on Industry Applications.

[16]  Mohsen Rahimi,et al.  Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement , 2010 .

[17]  S. K. Panda,et al.  Design of a Plug-In Repetitive Control Scheme for Eliminating Supply-Side Current Harmonics of Three-Phase PWM Boost Rectifiers Under Generalized Supply Voltage Conditions , 2010, IEEE Transactions on Power Electronics.

[18]  Debaprasad Kastha,et al.  Adaptive Speed Observer for a Stand-Alone Doubly Fed Induction Generator Feeding Nonlinear and Unbalanced Loads , 2012 .

[19]  J. Clare,et al.  Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators , 2007, IEEE Transactions on Energy Conversion.

[20]  Qing Liu,et al.  Investigation on the Faulty State of DFIG in a Microgrid , 2011, IEEE Transactions on Power Electronics.

[21]  G Pannell,et al.  Analytical Study of Grid-Fault Response of Wind Turbine Doubly Fed Induction Generator , 2010, IEEE Transactions on Energy Conversion.