A Comparison of Screw Insertion Torque and Pullout Strength

Purpose: Pullout strength of screws is a parameter used to evaluate plate screw fixation strength. However, screw fixation strength may be more closely related to its ability to generate sufficient insertion because stable nonlocked plate-screw fracture fixation requires sufficient compression between plate and bone such that no motion occurs between the plate and bone under physiological loads. Compression is generated by tightening of screws. In osteoporotic cancellous bone, sufficient screw insertion torque may not be generated before screw stripping. The effect of screw thread pitch on generation of maximum insertion torque (MIT) and pullout strength (POS) was investigated in an osteoporotic cancellous bone model and the relationship between MIT and POS was analyzed. Methods: Stainless steel screws with constant major (5.0 mm) and minor (2.7 mm) diameters but with varying thread pitches (1, 1.2, 1.5, 1.6, and 1.75 mm) were tested for MIT and POS in a validated osteoporotic surrogate for cancellous bone (density of 160 kg/m3 [10 lbs/ft3]). MIT was measured with a torque-measuring hex driver for screws inserted through a one-third tubular plate. POS was measured after insertion of screws to a depth of 20 mm based on the Standard Specification and Test Methods for Metallic Medical Bone Screws (ASTM F 543-07). Five screws were tested for each failure mode and screw design. The relationship between MIT and compressive force between the plate and bone surrogate was evaluated using pressure-sensitive film. Results: There was a significant difference in mean MIT based on screw pitch (P < 0.0001), whereas POS did not show statistically significant differences among the different screw pitches (P = 0.052). Small screw pitches (1.0 mm and 1.2 mm) had lower MIT and were distinguished from large pitches (1.5 mm, 1.6 mm, and the 1.75 mm) with higher MIT. For POS, only the 1-mm and 1.6-mm pitch screws were found to be different from each other. Linear regression analysis of MIT revealed a moderate correlation to the screw pitch (R2 = 0.67, P < 0.0001), whereas the analysis of POS suggested no correlation to the screw pitch (R2 = 0.28, P = 0.006). Pearson correlation analysis indicated no correlation between MIT and POS (P = 0.069, r = −0.37). A linear relationship of increased compression between the plate and bone surrogate was found for increasing screw torque (R2 = 0.97). Conclusions: These results indicate that the ability of different screw designs to generate high screw insertion torque in a model of osteoporotic cancellous bone is unrelated to their pullout strength. Therefore, extrapolation of results for POS to identify optimal screw design for osteoporotic bone may not be valid. Screw designs that optimize MIT should be sought for fixation in osteoporotic bone.

[1]  J. Brems,et al.  Effect of insertion torque on bone screw pullout strength. , 2001, Orthopedics.

[2]  G. Njus,et al.  Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone. , 2008, The Journal of trauma.

[3]  R. Zdero,et al.  The effect of screw pullout rate on screw purchase in synthetic cancellous bone. , 2009, Journal of biomechanical engineering.

[4]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[5]  K. Reynolds,et al.  Effect of Screw Torque Level on Cortical Bone Pullout Strength , 2007, Journal of orthopaedic trauma.

[6]  C. Kissel,et al.  Comparison of pullout strength of small-diameter cannulated and solid-core screws. , 2003, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.

[7]  R. McLain,et al.  Pedicle screw fixation strength: pullout versus insertional torque. , 2004, The spine journal : official journal of the North American Spine Society.

[8]  G. Njus,et al.  The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. , 2008, The Journal of trauma.

[9]  Jacob Cohen Statistical Power Analysis for the Behavioral Sciences , 1969, The SAGE Encyclopedia of Research Design.

[10]  C. E. Bowman,et al.  Holding power of orthopedic screws in bone. , 1970, Clinical orthopaedics and related research.

[11]  D J Downey,et al.  Optimizing Bone Screw Pullout Force , 1990, Journal of orthopaedic trauma.

[12]  A. Kapatkin,et al.  Pullout properties of 3.5-mm AO/ASIF self-tapping and cortex screws in a uniform synthetic material and in canine bone. , 2001, Veterinary surgery : VS.

[13]  Erik N. Kubiak,et al.  Biomechanics of Locked Plates and Screws , 2004, Journal of orthopaedic trauma.

[14]  R. Crawford,et al.  Stripping torque as a predictor of successful internal fracture fixation , 2005, ANZ journal of surgery.

[15]  R M Harrington,et al.  Factors affecting the pullout strength of cancellous bone screws. , 1996, Journal of biomechanical engineering.