Continuous quantitative monitoring of powder mixing dynamics by near-infrared spectroscopy

FT-NIR spectroscopy with a fiber optical reflection probe was applied as a process analytical technology tool for the continuous quantitative in-line monitoring of pharmaceutical powder mixing processes in a bladed mixer. Two powders, acetyl salicylic acid as an active pharmaceutical ingredient (API) and α-lactose monohydrate as an excipient were characterized in advance in terms of shear cell tests, flowability tests and particle-size determination to deduce flow properties of the powders. For the quantitative monitoring of the API content, two predictive models were developed with partial-least-squares calibration based on off-line calibration. On the basis of these predictive models, powder agitation and mixing times until blend uniformity were quantitatively monitored. Mixing experiments with systematically varied filling levels and filling protocols showed a strong variation in mixing, but eventually yielded uniform powder blend. Simulation results from the literature were linked to our experimental findings in order to identify and elucidate the effects of convective and diffusive mixing. In accordance to the international conference on harmonization acceptance level of 5% for the nominal API content, UV/Vis reference measurements were performed to verify the blend uniformity as predicted by the NIR measurements.

[1]  L. Danielsson,et al.  Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy , 2002 .

[2]  Y. Roggo,et al.  A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies. , 2007, Journal of pharmaceutical and biomedical analysis.

[3]  John Bridgwater,et al.  Granular flow over a flat-bladed stirrer , 2001 .

[4]  Fernando J. Muzzio Engineering Approaches for Pharmaceutical Process Scale-Up, Validation, Optimization, and Control in the Process and Analytical Technology (PAT) Era , 2005 .

[5]  Manel Alcalà,et al.  Analysis of low content drug tablets by transmission near infrared spectroscopy: selection of calibration ranges according to multivariate detection and quantitation limits of PLS models. , 2008, Journal of pharmaceutical sciences.

[6]  Yoshinobu Sato,et al.  Numerical analysis of agitation torque and particle motion in a high shear mixer , 2008 .

[7]  J. Drennen,et al.  Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity. , 2001, Journal of pharmaceutical sciences.

[8]  Benjamin J. Glasser,et al.  Large-scale powder mixer simulations using massively parallel GPUarchitectures , 2010 .

[9]  Benjamin J. Glasser,et al.  Polydisperse granular flows in a bladed mixer: Experiments and simulations of cohesionless spheres , 2011 .

[10]  Aibing Yu,et al.  Segregation of binary mixture of particles in a bladed mixer , 2003 .

[11]  Benjamin J. Glasser,et al.  Discrete element simulation of free flowing grains in a four‐bladed mixer , 2009 .

[12]  Abhay Gupta,et al.  Real-time on-line blend uniformity monitoring using near-infrared reflectance spectrometry: a noninvasive off-line calibration approach. , 2009, Journal of pharmaceutical and biomedical analysis.

[13]  Weiyong. Li,et al.  The effect of beam size on real-time determination of powder blend homogeneity by an online near infrared sensor. , 2007, Journal of pharmaceutical and biomedical analysis.

[14]  R. Reed,et al.  In-line monitoring of moisture content in fluid bed dryers using near-IR spectroscopy with consideration of sampling effects on method accuracy. , 2005, Analytical chemistry.

[15]  Emil W. Ciurczak,et al.  Handbook of Near-Infrared Analysis , 1992 .

[16]  Magnus Fransson,et al.  Real-Time assessment of granule and tablet properties using in-line data from a high-shear granulation process. , 2008, Journal of pharmaceutical sciences.

[17]  R L Carr,et al.  EVALUATING FLOW PROPERTIES OF SOLIDS , 1965 .

[18]  L. Danielsson,et al.  Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis , 2000 .

[19]  Benjamin J. Glasser,et al.  Mixing characteristics of wet granular matter in a bladed mixer , 2010 .

[20]  D. Massart,et al.  Near-infrared spectroscopy applications in pharmaceutical analysis. , 2007, Talanta.

[21]  R. D. Jee,et al.  Meeting the International Conference on Harmonisation's Guidelines on Validation of Analytical Procedures: quantification as exemplified by a near-infrared reflectance assay of paracetamol in intact tablets. , 2000, The Analyst.

[22]  James Prescott,et al.  On powder flowability , 2000 .

[23]  Fernando J. Muzzio,et al.  Characterization of continuous convective powder mixing processes , 2008 .

[24]  S. Barringer,et al.  Flow property measurement of food powders and sensitivity of Jenike’s hopper design methodology to the measured values , 2004 .

[25]  Benoît Igne,et al.  Pharmaceutical and Medical Applications of Near-Infrared Spectroscopy , 2002 .

[26]  L. Danielsson,et al.  Estimation of effective sample size when analysing powders with diffuse reflectance near-infrared spectrometry , 1998 .

[27]  Aibing Yu,et al.  Simulated and measured flow of granules in a bladed mixer—a detailed comparison , 2001 .

[28]  S. Sekulic,et al.  Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part II. Qualitative approaches to blend evaluation. , 1998, Journal of pharmaceutical and biomedical analysis.

[29]  H. Siesler,et al.  Near-infrared spectroscopy:principles,instruments,applications , 2002 .

[30]  Aibing Yu,et al.  Microdynamic analysis of the particle flow in a cylindrical bladed mixer , 2004 .

[31]  Michael Levin,et al.  Pharmaceutical process scale-up , 2001 .

[32]  Benjamin J. Glasser,et al.  Granular flow and Segregation in a four-bladed mixer , 2005 .

[33]  Benjamin J. Glasser,et al.  Characterization of granular flow of wet solids in a bladed mixer , 2006 .

[34]  D. T. Witte,et al.  Vibrational spectrometry for the assessment of active substance in metoprolol tablets: a comparison between transmission and diffuse reflectance near-infrared spectrometry. , 1996, Journal of pharmaceutical and biomedical analysis.

[35]  Fernando J. Muzzio,et al.  Sampling practices in powder blending , 1997 .

[36]  Benjamin J. Glasser,et al.  The effect of mixer properties and fill level on granular flow in a bladed mixer , 2009 .

[37]  P. K. Aldridge,et al.  On-line monitoring of powder blend homogeneity by near-infrared spectroscopy. , 1996, Analytical chemistry.

[38]  C. Bodson,et al.  Comparison of FT-NIR transmission and UV-vis spectrophotometry to follow the mixing kinetics and to assay low-dose tablets containing riboflavin. , 2006, Journal of pharmaceutical and biomedical analysis.

[39]  M. Iwunze Absorptiometric Determination of Acetylsalicylic Acid in Aqueous Ethanolic Solution , 2008 .

[40]  Troy Shinbrot,et al.  Powder technology in the pharmaceutical industry: the need to catch up fast , 2002 .

[41]  Benjamin J. Glasser,et al.  Experiments and simulations of cohesionless particles with varying roughness in a bladed mixer , 2010 .

[42]  J. Rantanen,et al.  Use of in-line near-infrared spectroscopy in combination with chemometrics for improved understanding of pharmaceutical processes. , 2005, Analytical chemistry.

[43]  J. Coello,et al.  Near-infrared spectroscopy in the pharmaceutical industry. , 1998, The Analyst.

[44]  Gabriele Reich,et al.  Near-infrared spectroscopy and imaging: basic principles and pharmaceutical applications. , 2005, Advanced drug delivery reviews.

[45]  D. B. Hibbert Multivariate calibration and classification - T. Naes, T. Isaksson, T. Fearn and T. Davis, NIR Publications, Chichester, 2002, ISBN 0 9528666 2 5, UK @$45.00, US$75.00 , 2004 .

[46]  J. Fricke,et al.  Effective Sample Size in Diffuse Reflectance Near-IR Spectrometry. , 1999, Analytical chemistry.

[47]  David Littlejohn,et al.  Real-time monitoring of powder mixing in a convective blender using non-invasive reflectance NIR spectrometry. , 2008, The Analyst.