Novel catheter enabling simultaneous radiofrequency ablation and optical coherence reflectometry.

A novel radiofrequency ablation catheter has been developed with integrated custom designed optics, enabling real-time monitoring of radiofrequency ablation procedures through polarization-sensitive optical coherence reflectometry. The optics allow for proper tissue illumination through a view-port machined in the catheter tip, thus providing lesion depth control over the RF ablation treatment. The system was verified in an in-vitro model of swine myocardium. Optical performance and thermal stability was confirmed after more than 25 procedures, without any damage to the optical assembly induced by thermal stress or material degradation. The use of this catheter in RF ablation treatments may make possible to assess lesion depth during therapy, thus translating into a reduction of potential complications on the procedure.

[1]  Juan Cinca,et al.  Effects of Open‐Irrigated Radiofrequency Ablation Catheter Design on Lesion Formation and Complications: In Vitro Comparison of 6 Different Devices , 2013, Journal of cardiovascular electrophysiology.

[2]  Jan Berg,et al.  Catheter ablation of atrial fibrillation: how to modify the substrate? , 2014, Journal of the American College of Cardiology.

[3]  H Calkins,et al.  Temperature monitoring during radiofrequency catheter ablation of accessory pathways. , 1992, Circulation.

[4]  Michael W. Jenkins,et al.  Fiber-optic catheter-based polarization-sensitive OCT for radio-frequency ablation monitoring. , 2014, Optics letters.

[5]  A. Camm,et al.  Guidelines for the management of atrial fibrillation: the Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC). , 2010, European heart journal.

[6]  M. Wood Exposing gaps in linear radiofrequency lesions: form before function. , 2011, Circulation. Arrhythmia and electrophysiology.

[7]  T. Brosh,et al.  The influence of radiofrequency ablation patterns on length, histological and mechanical properties of tendons. , 2012, Muscles, ligaments and tendons journal.

[8]  J G Fujimoto,et al.  Three-dimensional optical coherence tomography of Barrett’s esophagus and buried glands beneath neosquamous epithelium following radiofrequency ablation , 2009, Endoscopy.

[9]  F. Marchlinski,et al.  Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. , 2000, Circulation.

[10]  Fei Zuo,et al.  Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter. , 2011, Heart rhythm.

[11]  A. Fercher,et al.  Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography. , 2001, Optics express.

[12]  Matthew Wright,et al.  Advances in Imaging for Atrial Fibrillation Ablation , 2011, Radiology research and practice.

[13]  Hue-Teh Shih,et al.  Radiofrequency Catheter Ablation of Ventricular Tachycardia in Patients Without Structural Heart Disease , 1992, Circulation.

[14]  Andrew M Rollins,et al.  In vivo intracardiac optical coherence tomography imaging through percutaneous access: toward image-guided radio-frequency ablation. , 2011, Journal of biomedical optics.

[15]  R Lazzara,et al.  Inverse relationship between electrode size and lesion size during radiofrequency ablation with active electrode cooling. , 1998, Circulation.

[16]  J P Ornato,et al.  Cardiology patient page: warning signs of a heart attack. , 2001, Circulation.

[17]  Jeremy N Ruskin,et al.  Assessment of Catheter Tip Contact Force Resulting in Cardiac Perforation in Swine Atria Using Force Sensing Technology , 2011, Circulation. Arrhythmia and electrophysiology.

[18]  Paul C. Nardella Radio Frequency Energy And Impedance Feedback , 1989, Photonics West - Lasers and Applications in Science and Engineering.