Progress on the 3H-3He mass difference using the compensated Penning trap spectrometer

The use of the compensated Penning trap to measure an ion's mass relative to some calibration ion is described along with the leading systematic effects which must be considered. In this respect, magnet stability should no longer be a major limitation. Sideband techniques are described that center ions in the trap and equilibrate the cyclotron motion. The spectrometer's accuracy has been checked at the 1-ppb level by comparing the same atom with different charge states. The present application determines preliminary atomic masses of both 3H and 3He. These can be combined to yield an endpoint energy for the tritium decay (relative to neutral ground states) of 18 588(10)eV.

[1]  Boyce,et al.  Two ions in a Penning trap: Implications for precision mass spectroscopy. , 1992, Physical review. A, Atomic, molecular, and optical physics.

[2]  Haas,et al.  Thousandfold improvement in the measured antiproton mass. , 1990, Physical review letters.

[3]  G. Werth,et al.  Measurement of the4He-D2 mass difference , 1990 .

[4]  Moore,et al.  Number dependency in the compensated Penning trap. , 1989, Physical review. A, General physics.

[5]  Flanagan,et al.  Single-ion cyclotron resonance measurement of M(CO+)/M(N2+). , 1989, Physical review letters.

[6]  P. Schwinberg,et al.  Physics accessible through ultrahigh resolution trapped ion mass spectroscopy , 1989 .

[7]  Bowles,et al.  Energy of the 32-keV transition of 83Krm and the atomic mass difference between 3H and 3He. , 1989, Physical review. C, Nuclear physics.

[8]  P. Schwinberg,et al.  Mass Ratio Spectroscopy and the Proton’s Atomic Mass , 1989 .

[9]  Gerald Gabrielse,et al.  Self-shielding superconducting solenoid systems , 1988 .

[10]  R. D. Knight,et al.  Summary of the Physics in Traps Panel , 1988 .

[11]  Barry N. Taylor,et al.  THE 1986 ADJUSTMENT OF THE FUNDAMENTAL PHYSICAL CONSTANTS: A REPORT OF THE CODATA TASK GROUP ON FUNDAMENTAL CONSTANTS , 1987 .

[12]  P. Schwinberg,et al.  Variable magnetic bottle for precision geonium experiments , 1986 .

[13]  G. Audi,et al.  Evaluation of the3H-3He atomic mass difference , 1985 .

[14]  Past,et al.  Precise 3H-3He mass difference for neutrino mass determination. , 1985, Physical review letters.

[15]  A. H. Wapstra,et al.  The 1983 atomic mass evaluation: (I). Atomic mass table , 1985 .

[16]  G. Gabrielse Detection, damping, and translating the center of the axial oscillation of a charged particle in a Penning trap with hyperbolic electrodes , 1984 .

[17]  G. Gabrielse Relaxation calculation of the electrostatic properties of compensated Penning traps with hyperbolic electrodes , 1983 .

[18]  G. Gabrielse,et al.  Precision spectroscopy of a charged particle in an imperfect Penning trap , 1982 .

[19]  S. Bailey,et al.  High Resolution Penning Trap as a Precision Mass-Ratio Spectrometer , 1980 .

[20]  P. Schwinberg,et al.  Electron Magnetic Moment from Geonium Spectra , 1978 .

[21]  D. Wineland,et al.  High mass resolution with a new variable anharmonicity Penning trap , 1976 .

[22]  David J. Wineland,et al.  Principles of the stored ion calorimeter , 1975 .

[23]  W. A. Payne,et al.  Abstracts of Contributed Papers , 1973 .