Design of a bending mechanism for automated cystoscope

Bladder cancer has a high recurrence rate, which requires years of regular postoperative surveillance to monitor cancer recurrence. Both of patients and urologists will be benefited from automated monitor processes. This paper presents the preliminary design of a segmented bending mechanism to steer an embedded imaging probe for automated visual inspection of the inside surface of the bladder. The suggested bending mechanism consists of three bending segments connected in series and forms the shape of a continuum robot with redundant degree of freedom. Every segment is controlled by two pairs of distributed thin wires. Its bending angle and bending direction can be controlled independently. To obtain perpendicular view on the bladder surface and maintain the required safety distance, the positions and orientations of the tip of the imaging probe are controlled by synchronized bending motions of all segments. Forward kinematics model of the proposed hyper-redundant mechanism is developed. Inverse kinematics based on exhaustive searching algorithm in the configuration space is used to find suitable bending configurations for specific view centers. Kinematics simulation results verify the effectiveness of the proposed bending mechanism and control method for scanning the entire bladder inner surface.

[1]  A. Jemal,et al.  Cancer Statistics, 2010 , 2010, CA: a cancer journal for clinicians.

[2]  Sangtae Park,et al.  Development of an Automated Steering Mechanism for Bladder Urothelium Surveillance. , 2009, Journal of medical devices.

[3]  A Pollack,et al.  NCCN urothelial cancer practice guidelines. National Comprehensive Cancer Network. , 1998, Oncology.

[4]  Robert J. Webster,et al.  Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review , 2010, Int. J. Robotics Res..

[5]  Ian D. Walker,et al.  Kinematics for multisection continuum robots , 2006, IEEE Transactions on Robotics.

[6]  Ian D. Walker,et al.  Kinematics and the Implementation of an Elephant's Trunk Manipulator and Other Continuum Style Robots , 2003, J. Field Robotics.

[7]  Pierre E. Dupont,et al.  Stiffness Control of Surgical Continuum Manipulators , 2011, IEEE Transactions on Robotics.

[8]  Henry Buller,et al.  Wolf , 2013 .

[9]  Eric J. Seibel,et al.  Constructing spherical panoramas of a bladder phantom from endoscopic video using bundle adjustment , 2011, Medical Imaging.

[10]  P. Dario,et al.  An SMA-based flexible active endoscope for minimal invasive surgery , 1995 .

[11]  Michael R Hamblin,et al.  CA : A Cancer Journal for Clinicians , 2011 .

[12]  Masayoshi Esashi,et al.  A multilink active catheter with polyimide-based integrated CMOS interface circuits , 1999 .

[13]  Richard M. Murray,et al.  A Mathematical Introduction to Robotic Manipulation , 1994 .

[14]  James M. Kozlowski,et al.  NCCN Urothelial Cancer Practice Guidelines , 1998 .

[15]  Yacine Amirat,et al.  Modeling and Control of a Continuum Style Microrobot for Endovascular Surgery , 2011, IEEE Transactions on Robotics.

[16]  Byong-Ho Park,et al.  Laser-Machined Shape Memory Alloy Actuators for Active Catheters , 2007, IEEE/ASME Transactions on Mechatronics.

[17]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[18]  Thomas R. Kurfess,et al.  Robotics And Automation Handbook , 2019 .

[19]  Eric J. Seibel,et al.  Automated 3D Mosaicing and Scan Trajectories for Surveillance of Bladder Cancer , 2011 .

[20]  P. Schellhammer,et al.  Guideline for the management of nonmuscle invasive bladder cancer (stages Ta, T1, and Tis): 2007 update. , 2007, The Journal of urology.

[21]  Byung-Ju Yi,et al.  Design of a spring backbone micro endoscope , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.