Economic analysis of data center cooling strategies

Abstract Advancements in information technology have led to an increasing demand for data centers (DCs), and the energy consumption of DCs has gained attention worldwide. Many researchers have attempted to develop efficient DC cooling systems to reduce the energy required for cooling DCs, however, there are limitations in identifying the effect of such systems from the economic perspective. Subsequently, project owners find it difficult to decide whether to apply these systems to their particular DCs. The present research aims to analyze the economic performance of seven cooling strategies developed by the combinations of widely used DC cooling systems. The economic performance of each strategy is estimated by the life cycle cost analysis technique, and the analysis results show that Strategy 5 (A2_M: air-side economizer and supplementary cooling by a mechanical system) yields economic benefits of 26.84% in comparison to the conventional cooling system. The proposed research methodology and obtained results are expected to aid project owners in making effective decisions regarding the selection of an appropriate cooling strategy from an economic perspective.

[1]  Jetsadaporn Priyadumkol,et al.  Application of the combined air-conditioning systems for energy conservation in data center , 2014 .

[2]  Jeffrey Rambo,et al.  Numerical Modeling of Perforated Tile Flow Distribution in a Raised-Floor Data Center , 2010 .

[3]  Jeffrey Rambo,et al.  Modeling of data center airflow and heat transfer: State of the art and future trends , 2007, Distributed and Parallel Databases.

[4]  KimYongSu,et al.  Economic Evaluation for Heating and Cooling System by Using Gas Energy and Geothermal Energy Based on LCC Analysis , 2011 .

[5]  Eric Arquis,et al.  Data center optimization using PID regulation in CFD simulations , 2013 .

[6]  Xiaodong Qian,et al.  Entransy and exergy analyses of airflow organization in data centers , 2015 .

[7]  Hendrik F. Hamann,et al.  Heat transfer modeling in data centers , 2011 .

[8]  Jae-Weon Jeong,et al.  Energy saving potential of various air-side economizers in a modular data center , 2015 .

[9]  Jinkyun Cho,et al.  Evaluation of air distribution system's airflow performance for cooling energy savings in high-density data centers , 2014 .

[10]  Niraj Tolia,et al.  Opportunities and challenges to unify workload, power, and cooling management in data centers , 2010, OPSR.

[11]  Kuei-Peng Lee,et al.  Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones , 2013 .

[12]  Paul J. Kühn,et al.  Automatic energy efficiency management of data center resources by load-dependent server activation and sleep modes , 2015, Ad Hoc Networks.

[13]  Siew Eang Lee,et al.  Case study of data centers’ energy performance , 2006 .

[14]  Zhang Hainan,et al.  Free cooling of data centers: A review , 2014 .

[15]  Suhas V. Patankar,et al.  Airflow distribution through perforated tiles in raised-floor data centers , 2006 .

[16]  Atul Bhargav,et al.  Advances in data center thermal management , 2015 .

[17]  Lizhe Wang,et al.  Thermal aware workload placement with task-temperature profiles in a data center , 2011, The Journal of Supercomputing.

[18]  Janghoo Seo,et al.  Assessment of the economic performance of vacuum insulation panels for housing projects , 2014 .

[19]  Jaume Salom,et al.  Energy efficiency and renewable energy integration in data centres. Strategies and modelling review , 2015 .

[20]  S. Patankar Airflow and Cooling in a Data Center , 2010 .

[21]  Saman K. Halgamuge,et al.  Potential of air-side economizers for data center cooling: A case study for key Australian cities , 2013 .

[22]  Roger R. Schmidt,et al.  Cluster of High-Powered Racks Within a Raised-Floor Computer Data Center: Effect of Perforated Tile Flow Distribution on Rack Inlet Air Temperatures , 2004 .

[23]  Bahgat Sammakia,et al.  Airflow and temperature distribution optimization in data centers using artificial neural networks , 2013 .

[24]  Cheng-Xian Lin,et al.  A multi-zone building energy simulation of a data center model with hot and cold aisles , 2014 .

[25]  Godfried Augenbroe,et al.  Energy conservation effects of a multi-stage outdoor air enabled cooling system in a data center , 2017 .