Long-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement

Background: Data on long-term outcomes after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) are scarce. The objective of this study was to determine the long-term clinical outcomes and structural valve degeneration (SVD) over time in patients undergoing ViV-TAVR. Methods and Results: Consecutive patients undergoing ViV-TAVR in 9 centers between 2009 and 2015 were included. Patients were followed yearly, and clinical and echocardiography data were collected prospectively. SVD was defined as subclinical (increase >10 mm Hg in mean transvalvular gradient+decrease >0.3 cm2 in valve area or new-onset mild or moderate aortic regurgitation) and clinically relevant (increase >20 mm Hg in mean transvalvular gradient+decrease >0.6 cm2 in valve area or new-onset moderate-to-severe aortic regurgitation). A total of 116 patients (mean age, 76±11 years; 64.7% male; mean Society of Thoracic Surgeons score, 8.0±5.1%) were included. Balloon- and self-expandable valves were used in 47.9% and 52.1% of patients, respectively, and 30-day mortality was 6.9%. At a median follow-up of 3 years (range, 2–7 years), 30 patients (25.9%) had died, 20 of them (17.2%) from cardiovascular causes. Average mean transvalvular gradients remained stable up to 5-year follow-up (P=0.92), but clinically relevant SVD occurred in 3/99 patients (3.0%), and 15/99 patients (15.1%) had subclinical SVD. One patient with SVD had redo ViV-TAVR. Conclusions: About one-fourth of ViV-TAVR recipients had died after a median follow-up of 3 years. Overall valve hemodynamics remained stable over time and clinically relevant SVD was infrequent, but 1 out of 10 patients exhibited some degree of SVD.

[1]  D. Dey,et al.  High-pressure post-dilation following transcatheter valve-in-valve implantation in small surgical valves. , 2018, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[2]  M. Taguri,et al.  Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients: The OCEAN-TAVI Registry. , 2018, JACC. Cardiovascular interventions.

[3]  P. Pibarot,et al.  Long-Term Outcomes Following Surgical Aortic Bioprosthesis Implantation. , 2018, Journal of the American College of Cardiology.

[4]  E. Navarese,et al.  Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated aortic valve bioprostheses: systematic review and meta-analysis , 2018, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  R. Lange,et al.  Incidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve , 2018, Heart.

[6]  I. Barbash,et al.  Comparison of Outcome of Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis in 3 Age Groups (≤70; 71 to 80, and ≥81 Years). , 2017, The American journal of cardiology.

[7]  Jeroen J. Bax,et al.  2017 ESC/EACTS Guidelines for the management of valvular heart disease. , 2017, European heart journal.

[8]  V. Auffret,et al.  Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives , 2017, Circulation.

[9]  P. Pibarot,et al.  Aortic Bioprosthetic Valve Durability: Incidence, Mechanisms, Predictors, and Management of Surgical and Transcatheter Valve Degeneration. , 2017, Journal of the American College of Cardiology.

[10]  D. Dvir,et al.  Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement , 2017, Circulation. Cardiovascular interventions.

[11]  L. Fleisher,et al.  2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. , 2017, Journal of the American College of Cardiology.

[12]  J. Leipsic,et al.  Transcatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses: PARTNER 2 Valve-in-Valve Registry. , 2017, Journal of the American College of Cardiology.

[13]  J. Coselli,et al.  3-Year Outcomes in High-Risk Patients Who Underwent Surgical or Transcatheter Aortic Valve Replacement. , 2016, Journal of the American College of Cardiology.

[14]  J. Zamorano,et al.  Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. , 2016, European heart journal cardiovascular Imaging.

[15]  B. Carabello,et al.  Operationalizing the 2014 ACC/AHA Guidelines for Valvular Heart Disease: A Guide for Clinicians. , 2016, Journal of the American College of Cardiology.

[16]  P. Pibarot,et al.  Predictors and impact of myocardial injury after transcatheter aortic valve replacement: a multicenter registry. , 2015, Journal of the American College of Cardiology.

[17]  R. Puri,et al.  Transcatheter Valve-in-Valve and Valve-in-Ring for Treating Aortic and Mitral Surgical Prosthetic Dysfunction. , 2015, Journal of the American College of Cardiology.

[18]  M. Mack,et al.  5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial , 2015, The Lancet.

[19]  K. Kuck,et al.  Comparison of outcomes of patients with left ventricular ejection fractions ≤30% versus ≥30% having transcatheter aortic valve implantation (from the German Transcatheter Aortic Valve Interventions Registry). , 2015, The American journal of cardiology.

[20]  M. Mack,et al.  Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis. , 2014, Journal of the American College of Cardiology.

[21]  M. Pasic,et al.  Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. , 2014, JAMA.

[22]  R. Attia,et al.  Effect of valve design on the stent internal diameter of a bioprosthetic valve: a concept of true internal diameter and its implications for the valve-in-valve procedure. , 2014, JACC. Cardiovascular interventions.

[23]  A. Cribier,et al.  Performance analysis of EuroSCORE II compared to the original logistic EuroSCORE and STS scores for predicting 30-day mortality after transcatheter aortic valve replacement. , 2013, The American journal of cardiology.

[24]  Anson Cheung,et al.  5-year outcome after transcatheter aortic valve implantation. , 2013, Journal of the American College of Cardiology.

[25]  J. Webb,et al.  Adverse Effects Associated With Transcatheter Aortic Valve Implantation , 2013, Annals of Internal Medicine.

[26]  M. Mack,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. , 2012, Journal of the American College of Cardiology.

[27]  C. Hengstenberg,et al.  Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves: Results From the Global Valve-in-Valve Registry , 2012, Circulation.

[28]  Jennifer Taylor,et al.  ESC/EACTS Guidelines on the management of valvular heart disease. , 2012, European heart journal.

[29]  J. Webb,et al.  567 Adverse Effects Associated With Transcatheter Aortic Valve Implantation: A Meta-Analysis of Contemporary Studies , 2012 .

[30]  Philippe Pibarot,et al.  The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. , 2012, European heart journal.

[31]  Pascal Vranckx,et al.  Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. , 2011, Journal of the American College of Cardiology.

[32]  P. Serruys,et al.  Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium , 2010, European heart journal.

[33]  A. DeAnda,et al.  Reoperative valve surgery in the elderly: predictors of risk and long-term survival. , 2010, The Annals of thoracic surgery.

[34]  Bijoy K Khandheria,et al.  Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Card , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[35]  Sean M. O'Brien,et al.  The Society of Thoracic Surgeons 2008 cardiac surgery risk models: part 2--isolated valve surgery. , 2009, The Annals of thoracic surgery.

[36]  M. Maganti,et al.  Redo valvular surgery in elderly patients. , 2009, The Annals of thoracic surgery.

[37]  P. Pibarot,et al.  Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. , 2000, Journal of the American College of Cardiology.

[38]  Tania Rodríguez-Gabella,et al.  Future of transcatheter aortic valve implantation — evolving clinical indications , 2018, Nature Reviews Cardiology.

[39]  Pascal Vranckx,et al.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. , 2012, Journal of the American College of Cardiology.

[40]  Sean M. O'Brien,et al.  Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database. , 2009, The Journal of thoracic and cardiovascular surgery.

[41]  J. Chambers,et al.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.