Extrapolating Local Lymph Node Assay EC3 Values To Estimate Relative Sensitizing Potency

The assessment of the potency of a skin sensitizing chemical is a key starting point for its subsequent risk assessment/management. The Local Lymph Node Assay can provide information on the relative skin sensitizing potency of contact allergens by interpolation from the dose response curve the concentration of a chemical required to elicit a threshold positive response (EC3 value). However, interpolation requires that the dose response curve have at least one stimulation index (SI) value above and one SI value below the threshold value of 3. For instances where all test concentrations result in SI values above 3, there was a need to develop a method that would permit estimation of EC3 values. This has been achieved by log-linear extrapolation using the two lowest test concentrations from the dose response curve. Before applying this approach, it is important that data quality is assessed. The dose response must include concentrations on the linear portion of the curve and, ideally, the SI induced by the lowest dose should approach 3. Judicious use of this approach for extrapolating EC3 values can provide information on a likely potency classification for use in risk assessment and may avoid the need for repeat animal testing.

[1]  I Kimber,et al.  Vehicle effects on skin sensitizing potency of four chemicals: assessment using the local lymph node assay , 2001, International journal of cosmetic science.

[2]  I Kimber,et al.  Classification of contact allergens according to potency: proposals. , 2003, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[3]  D. Basketter,et al.  Reproducible prediction of contact allergenic potency using the local lymph node assay , 2004, Contact dermatitis.

[4]  Ian Kimber,et al.  The local lymph node assay: past, present and future , 2002, Contact dermatitis.

[5]  I. Kimber,et al.  Use of the local lymph node assay for the estimation of relative contact allergenic potency , 2000, Contact dermatitis.

[6]  Ian Kimber,et al.  The suitability of hexyl cinnamic aldehyde as a calibrant for the murine local lymph node assay , 2001, Contact dermatitis.

[7]  Ian Kimber,et al.  A chemical dataset for evaluation of alternative approaches to skin‐sensitization testing , 2004, Contact dermatitis.

[8]  I Kimber,et al.  Contact allergenic potency: correlation of human and local lymph node assay data. , 2001, American journal of contact dermatitis : official journal of the American Contact Dermatitis Society.

[9]  I Kimber,et al.  Skin sensitization testing in potency and risk assessment. , 2001, Toxicological sciences : an official journal of the Society of Toxicology.

[10]  S. Felter,et al.  Understanding fragrance allergy using an exposure‐based risk assessment approach , 2001, Contact dermatitis.

[11]  W S Stokes,et al.  ICCVAM evaluation of the murine local lymph node assay. Conclusions and recommendations of an independent scientific peer review panel. , 2001, Regulatory toxicology and pharmacology : RTP.

[12]  I Kimber,et al.  A comparison of statistical approaches to the derivation of EC3 values from local lymph node assay dose responses , 1999, Journal of applied toxicology : JAT.

[13]  I Kimber,et al.  Thresholds in contact sensitization: theoretical and practical considerations. , 1999, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[14]  Ian Kimber,et al.  Compilation of Historical Local Lymph Node Data for Evaluation of Skin Sensitization Alternative Methods , 2005, Dermatitis : contact, atopic, occupational, drug.

[15]  I. Kimber,et al.  Local lymph node assay responses to paraphenylenediamine: intra‐ and inter‐laboratory evaluations , 1999, Journal of applied toxicology : JAT.