Small-animal tomography with a liquid-metal-jet x-ray source

X-ray tomography of small animals is an important tool for medical research. For high-resolution x-ray imaging of few-cm-thick samples such as, e.g., mice, high-brightness x-ray sources with energies in the few-10-keV range are required. In this paper we perform the first small-animal imaging and tomography experiments using liquid-metal-jet-anode x-ray sources. This type of source shows promise to increase the brightness of microfocus x-ray systems, but present sources are typically optimized for an energy of 9 keV. Here we describe the details of a high-brightness 24-keV electron-impact laboratory microfocus x-ray source based on continuous operation of a heated liquid-In/Ga-jet anode. The source normally operates with 40 W of electron-beam power focused onto the metal jet, producing a 7×7 μm2 FWHM x-ray spot. The peak spectral brightness is 4 × 109 photons / ( s × mm2 × mrad2 × 0.1%BW) at the 24.2 keV In Kα line. We use the new In/Ga source and an existing Ga/In/Sn source for high-resolution imaging and tomography of mice.

[1]  H. Hertz,et al.  Liquid-metal-jet anode x-ray tube , 2004 .

[2]  M J Paulus,et al.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research. , 2000, Neoplasia.

[3]  F. Parente,et al.  Some K X-ray relative transition probabilities for Z=47, 49, 52, 55 and 56 , 1989 .

[4]  Anna Burvall,et al.  Phase Retrieval in X-ray Phase-contrast Imaging Suitable for Tomography , 2022 .

[5]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[6]  D E Grider,et al.  Electron beam melting in microfocus X-ray tubes , 1986 .

[7]  H M Hertz,et al.  A 9 keV electron-impact liquid-gallium-jet x-ray source. , 2008, The Review of scientific instruments.

[8]  V. Cnudde,et al.  Software tools for quantification of X-ray microtomography at the UGCT , 2007 .

[9]  T E Gureyev,et al.  Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging. , 2002, Journal of microscopy.

[10]  Hans M. Hertz,et al.  Status of the liquid-metal-jet-anode electron-impact x-ray source , 2004, SPIE Optics + Photonics.

[11]  Hans M. Hertz,et al.  Liquid-metal-jet anode electron-impact x-ray source , 2003 .

[12]  G. Johnson,et al.  In vivo small-animal imaging using micro-CT and digital subtraction angiography , 2008, Physics in medicine and biology.

[13]  M. Krause,et al.  Atomic radiative and radiationless yields for K and L shells , 1979 .

[14]  H M Hertz,et al.  A 24 keV liquid-metal-jet x-ray source for biomedical applications. , 2011, The Review of scientific instruments.