Three-dimensional modeling of potential and electric-field distributions along an EHV ceramic post insulator covered with ice - Part I: Simulations of a melting period

The main objective of this paper is to determine the potential and electric-field distributions along a typical ceramic extremely-high-voltage post insulator covered with atmospheric ice during a melting period. Commercial software, Coulomb 3D, based on the boundary element method (BEM), was used for all of the three-dimensional modeling and simulations. It was demonstrated that the BEM is well suited for evaluating the effect of ice shedding on the potential and electric-field distributions along an ice-covered insulator during a melting period. The results obtained show that the length and number of ice free zones, also called air gaps, are the major parameters that affect the applied voltage distribution along an ice-covered insulator. The mean electric field per arcing distance, affected mainly by the air-gap lengths, can provide a good indication of the presence of partial arcing along the different air gaps.

[1]  E. Asenjo,et al.  Solution of Low Frequency Complex Fields in Polluted Insulators by Means of the Finite Element Method , 1997 .

[2]  J. Hanssen,et al.  Long range transported pollutants and conductivity of atmospheric ice on insulators , 1993 .

[3]  Caixin Sun,et al.  AC flashover performance of iced insulators , 1988, Proceedings., Second International Conference on Properties and Applications of Dielectric Materials.

[4]  Masoud Farzaneh,et al.  An experimental study of flashover performance of various post insulators under icing conditions , 2000, 2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132).

[5]  E. Cherney Flashover Performance of Artificially Contaminated and ICED Long-Rod Transmission Line Insulators , 1980, IEEE Transactions on Power Apparatus and Systems.

[6]  B. Sikorski,et al.  Electric field calculation for an axially-symmetric insulator with surface contamination , 1994 .

[7]  J. S. Forrest,et al.  Research on the performance of high-voltage insulators in polluted atmospheres , 1960 .

[8]  C. Volat,et al.  Electric field modelling around an ice-covered insulator using boundary element method , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).

[9]  M. Farzaneh,et al.  Flashover problems caused by ice build up on insulators , 1995 .

[10]  M. Farzaneh,et al.  A Study of Surface Conductivity And Flashover Voltage of Ice Samples Formed Under Various Freezing Conditions , 1996 .

[11]  M. Farzaneh,et al.  AC flashover performance of insulators covered with artificial ice , 1995 .

[12]  Katsuhiko Naito,et al.  Performance of Insulators Covered With Snow or Ice , 1979, IEEE Transactions on Power Apparatus and Systems.