Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring

This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

[1]  Sang-Hoon Lim,et al.  Fabrication of the flexible pentacene thin-film transistors on 304 and 430 stainless steel (SS) substrate , 2009 .

[2]  Ren C. Luo,et al.  Design and implementation of capacitive proximity sensor using microelectromechanical systems technology , 1998, IEEE Trans. Ind. Electron..

[3]  J McLaughlin,et al.  Piezoelectric sensor determination of arterial pulse wave velocity. , 2003, Physiological measurement.

[4]  Benjamin C. K. Tee,et al.  Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. , 2010, Nature materials.

[5]  Laxman Saggere,et al.  PZT thin films for low voltage actuation: Fabrication and characterization of the transverse piezoelectric coefficient , 2007 .

[6]  Peter Ryser,et al.  Pyroelectric thin-film sensor array , 1997 .

[7]  Osamu Fukuda,et al.  Preparation of Oriented Aluminum Nitride Thin Films on Polyimide Films and Piezoelectric Response with High Thermal Stability and Flexibility , 2007 .

[8]  Yu-Cheng Lin,et al.  Flexible electronics sensors for tactile multiscanning. , 2009, The Review of scientific instruments.

[9]  Sang-Gook Kim,et al.  MEMS power generator with transverse mode thin film PZT , 2005 .

[10]  Wen-Yang Chang,et al.  A Large Area Flexible Array Sensors Using Screen Printing Technology , 2009, Journal of Display Technology.

[11]  Jae-Young Choi,et al.  Piezoelectric touch-sensitive flexible hybrid energy harvesting nanoarchitectures , 2010, Nanotechnology.

[12]  Ernesto Suaste-Gómez,et al.  A Piezoelectric Plethysmograph Sensor Based on a Pt Wire Implanted Lead Lanthanum Zirconate Titanate Bulk Ceramic , 2010, Sensors.

[13]  B. Courtois,et al.  A sweeping mode integrated fingerprint sensor with 256 tactile microbeams , 2004, Journal of Microelectromechanical Systems.

[14]  Vânia Almeida,et al.  Characterization of a double probe for local pulse wave velocity assessment , 2010, Physiological measurement.

[15]  Kazuhiro Nonaka,et al.  Flexible pulse-wave sensors from oriented aluminum nitride nanocolumns , 2003 .

[16]  E. Meng,et al.  Parylene-Based Electrochemical-MEMS Transducers , 2010, Journal of Microelectromechanical Systems.

[17]  J. Spigulis Optical noninvasive monitoring of skin blood pulsations , 2005 .

[18]  C. K. Lee,et al.  Piezoelectric MEMS generators fabricated with an aerosol deposition PZT thin film , 2009 .

[19]  T. Kamei,et al.  Novel surface structure and its fabrication process for MEMS fingerprint sensor , 2005, IEEE Transactions on Electron Devices.

[20]  Influences of thin Ni layer on the electrical and absorption properties of PZT thin film pyroelectric IR sensors , 2000 .

[21]  Craig A. Rogers,et al.  Qualitative impedance-based health monitoring of civil infrastructures , 1998 .

[22]  Sang-Gook Kim,et al.  Energy harvesting MEMS device based on thin film piezoelectric cantilevers , 2006 .

[23]  Panayiotis A. Kyriacou,et al.  Pilot investigation of photoplethysmographic signals and blood oxygen saturation values during blood pressure cuff-induced hypoperfusion , 2009 .

[24]  M.-Y. Cheng,et al.  A flexible capacitive tactile sensing array with floating electrodes , 2009 .

[25]  E. Berjano,et al.  Pulse Wave Velocity and Digital Volume Pulse as Indirect Estimators of Blood Pressure: Pilot Study on Healthy Volunteers , 2009, Cardiovascular engineering.

[26]  Óscar Oballe-Peinado,et al.  Three Realizations and Comparison of Hardware for Piezoresistive Tactile Sensors , 2011, Sensors.

[27]  Alan Bernjak,et al.  Pulse transit times to the capillary bed evaluated by laser Doppler flowmetry , 2009, Physiological measurement.

[28]  Hidekuni Takao,et al.  An Annular Mechanical Temperature Compensation Structure for Gas-Sealed Capacitive Pressure Sensor , 2012, Sensors.

[29]  Panayiotis A. Kyriacou,et al.  Evaluation of Electrical and Optical Plethysmography Sensors for Noninvasive Monitoring of Hemoglobin Concentration , 2012, Sensors.

[30]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[31]  S. Rhee,et al.  Resistive switching characteristics of ZnO thin film grown on stainless steel for flexible nonvolatile memory devices , 2009 .

[32]  Michael C. McAlpine,et al.  Piezoelectric ribbons printed onto rubber for flexible energy conversion. , 2010, Nano letters.

[33]  Chee Kiong Soh,et al.  Application of Electromechanical Impedance Technique for Engineering Structures: Review and Future Issues: , 2010 .

[34]  Jongsung Park,et al.  A piezoresistive tactile sensor based on carbon fibers and polymer substrates , 2009 .

[35]  F. Ko,et al.  Fabrication of a gas sensor with a piezoelectric PZT film deposited by a novel hydrothermal microwave-assisted annealing , 2007 .

[36]  T. Wong,et al.  Sol-gel derived mesoporous silica films used as low dielectric constant materials , 2004 .

[37]  Seiji Aoyagi,et al.  Proposal and development of arrayed sole sensor for legged robot and contact force detection using neural networks , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[38]  G. Metta,et al.  Towards Tactile Sensing System on Chip for Robotic Applications , 2011, IEEE Sensors Journal.

[39]  Chengkuo Lee,et al.  A 1-V Operated MEMS Variable Optical Attenuator Using Piezoelectric PZT Thin-Film Actuators , 2009, IEEE Journal of Selected Topics in Quantum Electronics.

[40]  E. Meng,et al.  Impedance-Based Force Transduction Within Fluid-Filled Parylene Microstructures , 2011, Journal of Microelectromechanical Systems.

[41]  D. Roy Mahapatra,et al.  An analytical model of constrained piezoelectric thin film sensors , 2004 .

[42]  Fabrizio Sarasini,et al.  Monitoring of Impacted Aramid‐Reinforced Composites by Embedded PVDF Acoustic Emission Sensors , 2008 .

[43]  João Cardoso,et al.  Piezoelectric probe for pressure waveform estimation in flexible tubes and its application to the cardiovascular system , 2011 .

[44]  R. Stutz,et al.  Wafer-Level Transfer Technologies for PZT-Based RF MEMS Switches , 2010, Journal of Microelectromechanical Systems.

[45]  Takaaki Suzuki,et al.  Characterization of Pb(Zr,Ti)O3 thin films deposited on stainless steel substrates by RF-magnetron sputtering for MEMS applications , 2006 .

[46]  Pasquale Arpaia,et al.  A piezo-film-based measurement system for global haemodynamic assessment , 2010, Physiological measurement.

[47]  Thor Bakke,et al.  A novel ultra-planar, long-stroke and low-voltage piezoelectric micromirror , 2010 .