Comparative Examination of Finishing Coils Available in Japan

Objective: In the final stage of coil embolization, microcatheter kickback often occurs and it may be difficult to fill the remaining space with a coil. To avoid microcatheter kickback and achieve successful embolization, soft type coils such as ED coil-10 Extra Soft type R (EDC-10ES) are frequently used as a finishing coil. We compared six different brands of finishing coils to evaluate the efficacy of EDC-10ES. Case Presentations: This paper presents a representative case of small cerebral aneurysm treated with only EDC-10 ES coils were presented. Furthermore, to compare the degree of coil softness and microcatheter kickback, we verified the in vitro coil performance of six different brands of finishing coils. The first experiment compared the degree of microcatheter kickback in the final stage of coil embolization and the second experiment tested the softness of the delivery wire. Conclusion: The results verified that EDC-10 ES has less microcatheter kickback in relation to both the coil and delivery wire, compared to the other finishing coils. Consequently, EDC-10 ES was evaluated as a coil with extremely high softness, allowing stable coil placement in the final stage of embolization.

[1]  J. Koyama,et al.  Characteristic features of coil delivery wires for cerebral aneurysm embolization , 2014 .

[2]  S. Nagasawa,et al.  Aneurysmal wall stress caused by platinum coils is not dependent on the size of a coil but on a diameter of the stock wire: in-vitro study , 2013 .

[3]  T. Wakabayashi,et al.  Phenomenon of straitening at proximal end of the coil during parent artery occlusion for the internal carotid artery aneurysm: case report , 2012 .

[4]  T. Wakabayashi,et al.  The Mechanism of Catheter Kickback in the Final Stage of Coil Embolization for Aneurysms: The Straightening Phenomenon , 2010, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences.

[5]  J. Byrne,et al.  Endovascular treatment of very small intracranial aneurysms. , 2010, Journal of neurosurgery.

[6]  A. Sano,et al.  コイル挿入力測定センサーによるコイル挿入力発生パターンに関する研究:コイル挿入方法,挿入速度の違いによって決まるコイルと動脈瘤壁との摩擦状態の検討から , 2010 .

[7]  A. Shinko,et al.  Coil embolization of small aneurysms with a maximum diameter of 3mm , 2010 .

[8]  M. Sluzewski,et al.  Clinical and Angiographic Results of Coiling of 196 Very Small (≤ 3 mm) Intracranial Aneurysms , 2009, American Journal of Neuroradiology.

[9]  C. Drake,et al.  Report of World Federation of Neurological Surgeons Committee on a Universal Subarachnoid Hemorrhage Grading Scale. , 1988, Journal of neurosurgery.

[10]  W. Hunt,et al.  Timing and perioperative care in intracranial aneurysm surgery. , 1974, Clinical neurosurgery.