Measuring nonconstant flow in magnetic resonance imaging.

An attempt is made to quantify rapid flow using magnetic resonance imaging techniques. An analysis is presented in which it is assumed that constant velocity gradients are present. A deconvolution scheme which can remove the blurring from motion with acceleration is developed. This allows improved resolution and velocity determination. Computer experiments were performed on simulated data, where the velocity drops from 100 cm/s to 50 cm/s over a distance of 5 cm. In noise-free data, velocities were recovered to within 2% of the lower velocity and, for data with 5% white noise, to within 6%

[1]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[2]  T Matsuda,et al.  Measurement of aortic blood flow with MR imaging: comparative study with Doppler US. , 1987, Radiology.

[3]  M Kiri,et al.  Visualization of moving fluid: quantitative analysis of blood flow velocity using MR imaging. , 1986, Radiology.

[4]  W. Bradley,et al.  Blood flow: magnetic resonance imaging. , 1985, Radiology.

[5]  J. Ford,et al.  Phase Alterations of Spin Echoes by Motion along Magnetic Field Gradients , 1985, Magnetic resonance in medicine.

[6]  Irene A. Stegun,et al.  Handbook of Mathematical Functions. , 1966 .

[7]  Frank Natterer,et al.  A Sobolev Space Analysis of Picture Reconstruction , 1980 .

[8]  C. S. Poon,et al.  Projection flow imaging by bolus tracking using stimulated echoes , 1989, Magnetic resonance in medicine.

[9]  A. Lent,et al.  An introduction to NMR imaging: From the Bloch equation to the imaging equation , 1983, Proceedings of the IEEE.

[10]  E R Reinhardt,et al.  Visualization and Measurement of Flow with Magnetic Resonance Imaging. Darstellung und Messung von Flußgeschwindigkeit mit bildgebender Kernresonanz , 1985, Biomedizinische Technik. Biomedical engineering.

[11]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[12]  K. Barth,et al.  Flow Measurement By Magnetic Resonance Imaging , 1985, Medical Imaging.

[13]  P. Pattany,et al.  Velocity and acceleration desensitization in 2DFT MR imaging , 1986 .

[14]  E M Haacke,et al.  In-plane vascular imaging: pulse sequence design and strategy. , 1988, Radiology.

[15]  R E Wendt,et al.  Motional phase artifacts in fourier transform MRI , 1989, Magnetic resonance in medicine.

[16]  L Axel,et al.  A time-of-flight method of measuring flow velocity by magnetic resonance imaging. , 1986, Magnetic resonance imaging.

[17]  L Axel,et al.  Blood flow effects in magnetic resonance imaging. , 1984, Magnetic resonance annual.

[18]  Rapid average‐flow velocity measurement by NMR , 1986, Magnetic resonance in medicine.

[19]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.