[Dose reduction and image quality in MDCT of the upper abdomen: potential of an adaptive post-processing filter].

PURPOSE To evaluate the effects of a 2D non-linear adaptive post-processing filter (2D-NLAF) on image quality in dose-reduced multi-detector CT (MDCT) of the upper abdomen. MATERIALS AND METHODS MDCT of the upper abdomen was simulated on a 64-slice scanner using a multi-modal anthropomorphic phantom (CIRS, Norfolk, USA). While keeping the collimation (64 x 0.6 mm) and pitch (p = 1) unchanged, the tube current (100 - 500 mAs) and tube potential (80 - 140 kVp) were varied to perform MDCT as high dose (CTDI > 20), middle dose (CTDI 10 - 20) and low dose (CTDI < 10) level protocols. Four independent blinded radiologists evaluated axial images with a thickness of 7 and 3 mm with respect to the presentation of "mesenteric low contrast lesions", "liver veins", "liver cysts", "renal cysts" and "big vessels". The subjective image quality of original data and post-processed images using a 2D-NLAF (SharpViewCT, Linköping, Sweden) was graded on a 5-point scale (from "1" not visible to "5" excellent) and statistically analyzed. The effective dose (E) was estimated using commercial software (CT-EXPO). RESULTS For all protocol groups, 2D-NLAF led to a significant improvement in subjective image quality for all examined lesions (p < 0.01), particularly at the protocols of middle dose (E: 5 - 8 mSv) and low dose level (E: 1 - 5 mSv). A maximum effect was seen in middle dose protocols for "low contrast lesions" (score "3.3" with filter versus "2.5" without) and "liver veins" ("4.5" versus "3.9"). CONCLUSION The phantom study indicates a potential dose reduction of up to 50 % in MDCT of the upper abdomen by use of a 2D-NLAF, which should be further examined in clinical trails.

[1]  Donald P. Frush,et al.  Pediatric CT: practical approach to diminish the radiation dose , 2002, Pediatric Radiology.

[2]  Reduction in dose from CT examinations of liver lesions with a new postprocessing filter: a ROC phantom study , 2008, Acta radiologica.

[3]  J. Blobel,et al.  5 Jahre Konzertierte Aktion Dosisreduktion CT - was wurde erreicht, was ist noch zu tun? , 2004 .

[4]  Thomas L Toth,et al.  Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. , 2003, Radiology.

[5]  A S Brody,et al.  Minimizing radiation dose for pediatric body applications of single-detector helical CT: strategies at a large Children's Hospital. , 2001, AJR. American journal of roentgenology.

[6]  T. Toth Dose reduction opportunities for CT scanners , 2002, Pediatric Radiology.

[7]  N. Müller,et al.  Low-dose high-resolution CT of lung parenchyma. , 1991, Radiology.

[8]  Jonas Nilsson Althén,et al.  Automatic tube-current modulation in CT--a comparison between different solutions. , 2005, Radiation protection dosimetry.

[9]  Kazuo Awai,et al.  Improvement of Low-Contrast Detectability in Low-Dose Hepatic Multidetector Computed Tomography Using a Novel Adaptive Filter: Evaluation With a Computer-Simulated Liver Including Tumors , 2006, Investigative radiology.

[10]  Rainer Raupach,et al.  CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics. , 2005, Radiology.

[11]  D. Blondin,et al.  Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma , 2007, European Radiology.

[12]  V. Dicken,et al.  Linear and Volume Measurements of Pulmonary Nodules at Different CT Dose Levels – Intrascan and Interscan Analysis , 2008, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[13]  Eckhardt Grabbe,et al.  Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter , 2002 .

[14]  Thomas L Toth,et al.  Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. , 2004, Radiology.