A Skills-Focused Approach to Improving Therapist Goniometry Accuracy Using a Simulation Laboratory

Goniometric measurements are widely used in the field of occupational therapy to measure range of motion, define and describe movement, and predict the functional implications of joint limitations. These measurements are further used in documentation and as a means of justifying reimbursement. While goniometrics are a hallmark of our practice, therapist competency is rarely assessed. This study sought to evaluate whether a skill focused, simulation assisted training could lead to improvements in accuracy and consistency of goniometric measurements. Ten therapists at a single facility completed goniometric testing utilizing a simulation module to assess three joint motions (shoulder abduction, elbow flexion and neck extension). Testing was followed by extended, joint specific education prior to retesting. Estimates of consistency improved for all joint motions from pre to post training. Measurement accuracy improved in shoulder abduction and neck extension. Therapists reported improved level of comfort for specific joint measurements and for goniometry in general. Training laboratories such as the one described in this paper, can be an effective way of establishing a consistent departmental standard, assessing current competency, and providing hands-on training in a new and innovative way.

[1]  Teresa D. Welch,et al.  Deliberate Practice and Skill Acquisition in Nursing Practice. , 2018, Journal of continuing education in nursing.

[2]  W. Tharion,et al.  Interrater and intrarater reliability of finger goniometric measurements. , 2010, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[3]  S. O’Driscoll,et al.  Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[4]  K. A. Ericsson,et al.  Deliberate practice and acquisition of expert performance: a general overview. , 2008, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[5]  Richard W. Bohannon,et al.  Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. , 1987, Physical therapy.

[6]  Bhupendra Rawal,et al.  Accuracy and Validity of Goniometer and Visual Assessments of Angular Joint Positions of the Hand and Wrist. , 2016, The Journal of hand surgery.

[7]  J. Plewes,et al.  Measurement of joint motion: A guide to goniometry , 1986 .

[8]  D. P. Bethea,et al.  Use of simulation in occupational therapy education: way of the future? , 2014, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[9]  S. Azen,et al.  Reliability of goniometric measurements. , 1978, Physical therapy.

[10]  D. Altman,et al.  Statistics notes: Cronbach's alpha , 1997 .

[11]  L. Hooper,et al.  Effectiveness of medical simulation in teaching medical students critical care medicine , 2017 .

[12]  J. Rogers,et al.  Wheelchair Transfer Simulations to Enhance Procedural Skills and Clinical Reasoning. , 2015, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[13]  A. Daluiski Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method , 2012 .

[14]  A. Shin,et al.  A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements. , 2016, The Journal of hand surgery.

[15]  William M. Stanish Categorical data analysis strategies using SAS software , 1986 .

[16]  Deliberate practice using validated metrics improves skill acquisition in performance of ultrasound-guided peripheral nerve block in a simulated setting. , 2018, Journal of clinical anesthesia.

[17]  D. Greenhalgh,et al.  Methods and Tools Used for the Measurement of Burn Scar Contracture , 2010, Journal of burn care & research : official publication of the American Burn Association.

[18]  Elisa L Zwerus,et al.  The reliability and validity of goniometric elbow measurements in adults: A systematic review of the literature , 2018, Shoulder & elbow.

[19]  Yara E van Kooij,et al.  The reliability and measurement error of protractor-based goniometry of the fingers: A systematic review. , 2017, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[20]  Gregory M Dodson,et al.  Simulation-based education with deliberate practice may improve intraoperative handoff skills: a pilot study. , 2014, Journal of clinical anesthesia.

[21]  M. Shamsi,et al.  Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle , 2019, BMC Sports Science, Medicine and Rehabilitation.