In vitro effectiveness study of three hydrodynamic thrombectomy devices.

PURPOSE To determine the in vitro efficacy of three hydrodynamic thrombectomy devices. MATERIALS AND METHODS Thrombectomy of clots was performed with three thrombectomy devices (Angiojet [AJ], Possis Medical, Minneapolis, Minn; Hydrolyser [HL] Cordis Europe, Roden, the Netherlands; and the Shredding Embolectomy Thrombectomy [SET] catheter, HP-Medica, Augsburg, Germany) in a flow model. RESULTS Mean thrombectomy time ranged from 10.22 seconds (HL) to 37.73 seconds (AJ with guide wire). For the AJ and HL, the use of guide wires prolonged thrombectomy time (P < .01). The AJ with and without a guide wire and the HL with a 0.018-inch guide wire worked isovolumetrically, whereas the mean ratio of applied saline and aspirated fluid for the other devices was different from 1, ranging from 0.54 to 0.72. Mean embolus weight with the AJ alone (56.44 mg) was significantly higher than that with the SET catheter alone (3.15 mg) and with a guide wire (1.31 mg, P < .01 for both) and the HL alone (3.9 mg, P < .05), as was the embolus weight with the HL with a 0.018-inch guide wire (66.5 mg) compared with the SET catheter with and without a guide wire (P < .01), AJ with a guide wire (22.33 mg, P < .05), the HL alone (P < .01), and the HL with a 0.025-inch guide wire (24.86 mg, P < .05). CONCLUSION The devices showed performance differences. The SET catheter alone and with a guide wire and the HL may bear an increased risk of procedure-related anemia. In clinical applications, hydrodynamic thrombectomy might substantially reduce the need for thrombolytic therapy.

[1]  T. Schmitz-Rode,et al.  New device for percutaneous fragmentation of pulmonary emboli. , 1991, Radiology.

[2]  W. Mali,et al.  Arterial thrombosis below the inguinal ligament: percutaneous treatment with a thrombosuction catheter. , 1996, Radiology.

[3]  H. Wellens,et al.  In vivo evaluation of the Hydrolyser hydrodynamic thrombectomy catheter. , 1994, Journal of vascular and interventional radiology : JVIR.

[4]  A. Bücker,et al.  Rheolytische Thrombektomie einer Beckenvene , 1995 .

[5]  T. Schmitz-Rode,et al.  Portal vein thrombosis after occlusion of a transjugular intrahepatic portosystemic shunt: recanalization with the impeller catheter. , 1994, Journal of vascular and interventional radiology : JVIR.

[6]  J. Morris,et al.  Rheolytic thrombectomy with use of the AngioJet-F105 catheter: preclinical evaluation of safety. , 1997, Journal of vascular and interventional radiology : JVIR.

[7]  T. Schmitz-Rode,et al.  Comparative in vitro study of two percutaneous hydrodynamic thrombectomy systems. , 1996, Journal of vascular and interventional radiology : JVIR.

[8]  J. Cranley,et al.  A method for extraction of arterial emboli and thrombi. , 1963, Surgery, gynecology & obstetrics.

[9]  H. Zerkowski,et al.  Results of mitral valve reconstruction in mitral valve insufficiency. , 1994, The Journal of cardiovascular surgery.

[10]  G. Wilson,et al.  Rheolytic catheter for percutaneous removal of thrombus. , 1992, Radiology.

[11]  T. Schmitz-Rode,et al.  Percutaneous mechanical thrombolysis. A comparative study of various rotational catheter systems. , 1991, Investigative radiology.

[12]  C. Zarins,et al.  Recanalization of obstructed arteries with a flexible, rotating tip catheter. , 1987, Radiology.

[13]  S. Furui,et al.  Saline-jet aspiration thrombectomy catheter. , 1993, AJR. American journal of roentgenology.

[14]  K. Amplatz,et al.  Mechanical thrombectomy: results of early experience. , 1993, Radiology.

[15]  W. Dassen,et al.  Distal embolization during thrombectomy with use of the hydrolyser (hydrodynamic thrombectomy catheter): in vitro testing. , 1997, Journal of vascular and interventional radiology : JVIR.

[16]  A. Crummy,et al.  Percutaneous aspiration thromboembolectomy. , 1985, Radiology.

[17]  J. Reekers,et al.  Catheter for percutaneous thrombectomy: first clinical experience. , 1993, Radiology.

[18]  W. Dassen,et al.  Comparison of arterial wall reaction after passage of the Hydrolyser device versus a thrombectomy balloon in an animal model. , 1996, Journal of vascular and interventional radiology : JVIR.

[19]  H. Wagner,et al.  Rapid thrombectomy with a hydrodynamic catheter: results from a prospective, multicenter trial. , 1997, Radiology.

[20]  K. Bohndorf,et al.  Perkutane, transluminale hydrodynamische Thrombektomie - Erste Ergebnisse , 1996 .

[21]  J. Listinsky The Use of Transrectal Ultrasound in the Diagnosis and Management of Prostate Cancer. Vol 237, Progress in Clinical and Biological Research , 1988 .

[22]  P. Dobrin,et al.  Mechanisms and prevention of arterial injuries caused by balloon embolectomy. , 1989, Surgery.

[23]  H. Aarts,et al.  Occluded hemodialysis shunts: Dutch multicenter experience with the hydrolyser catheter. , 1996, Radiology.

[24]  M. Leon,et al.  Functional Properties of a Prototype Rheolytic Catheter for Percutaneous Thrombectomy: In Vitro Investigations , 1994, Investigative radiology.

[25]  S. Müller-Hülsbeck,et al.  Technische Modifikation der rheolytischen Thrombektomie , 1996 .

[26]  J. Ritchie,et al.  Mechanical thrombolysis: a new rotational catheter approach for acute thrombi. , 1986, Circulation.

[27]  K. Amplatz,et al.  Mechanical clot dissolution: new concept. , 1989, Radiology.

[28]  K. Amplatz,et al.  Recirculation-type Amplatz clot macerator: determination of particle size and distribution. , 1993, Journal of vascular and interventional radiology : JVIR.

[29]  R. Guenther,et al.  Hydrodynamic thrombectomy of hemodialysis fistulas: first clinical results. , 1994, Journal of vascular and interventional radiology : JVIR.