Pacemaker and defibrillator combination therapy for recurrent ventricular tachycardia.

The judicious use of antitachycardia pacemakers can enhance the benefits of automatic implantable cardioverter defibrillators in certain patients. Both devices were implanted in 10 highly selected patients with drug-refractory pace-terminable sustained ventricular tachycardia. During the observation period of 8 +/- 4.8 months, the automatic pacemakers detected 1,542 episodes of ventricular tachycardia and appropriately managed 1,373. The automatic implantable defibrillator was activated at least once in every patient; on two documented occasions, the defibrillator discharged because the automatic pacemaker accelerated the tachycardia. Concomitant antiarrhythmic drugs could be reduced but not withdrawn. With meticulous device programming and testing, the two systems in combination can work synergistically to manage malignant ventricular arrhythmias in carefully selected patients.

[1]  J. Fisher,et al.  VT/VF: 60/60 Protection , 1990, Pacing and clinical electrophysiology : PACE.

[2]  Y. Rudy,et al.  Continuous Right Ventricular Volume Assessment by Catheter Measurement of Impedance for Antitachycardia System Control , 1989, Pacing and clinical electrophysiology : PACE.

[3]  B. Wilkoff,et al.  The Use of Beep‐O‐Grams in the Assessment of Automatic Implantahle Cardioverter Defibrillator Sensing Function , 1989, Pacing and clinical electrophysiology : PACE.

[4]  D. M. Newman,et al.  Permanent Antitachycardia Pacemaker Therapy for Ventricular Tachycardia , 1989, Pacing and clinical electrophysiology : PACE.

[5]  A. Camm,et al.  Implantable cardioverter‐defibrillators (ICDs) 1989: How close are we to the ideal device? , 1989, Clinical cardiology.

[6]  P. Tchou,et al.  Automatic implantable cardioverter defibrillators and survival of patients with left ventricular dysfunction and malignant ventricular arrhythmias. , 1988, Annals of internal medicine.

[7]  S. Barold,et al.  Long‐Term Management of Ventricular Tachycardia by Implantable Automatic Burst Tachycardia‐Terminating Pacemakers , 1986, Pacing and clinical electrophysiology : PACE.

[8]  J. Higgins Automatic burst extrastimulus pacemaker to treat recurrent ventricular tachycardia in a patient with mitral valve prolapse: more than 2,000 documented successful tachycardia terminations. , 1986, Journal of the American College of Cardiology.

[9]  R. Winkle,et al.  Results of operations for ventricular tachycardia in 105 patients. , 1986, The Journal of thoracic and cardiovascular surgery.

[10]  P. D. Chapman,et al.  The automatic implantable cardioverter-defibrillator: evaluating suspected inappropriate shocks. , 1986, Journal of the American College of Cardiology.

[11]  N. Kouchoukos,et al.  Combined bipolar dual chamber pacing and automatic implantable cardioverter/defibrillator. , 1986, Journal of the American College of Cardiology.

[12]  J. Alpert,et al.  A theoretically and practically more effective method for interruption of ventricular tachycardia: self-adapting autodecremental overdrive pacing. , 1986, Circulation.

[13]  H. Kulbertus,et al.  Programmable extrastimulus pacing for long-term management of supraventricular and ventricular tachycardias: clinical experience in 16 patients. , 1985, American heart journal.

[14]  G. Dehmer,et al.  Automatic Scanning Extrastimulus Pacemaker to Treat Ventricular Tachycardia * , 1985, Pacing and clinical electrophysiology : PACE.

[15]  R. Winkle,et al.  Practical aspects of automatic cardioverter/defibrillator implantation. , 1984, American heart journal.

[16]  A. Camm,et al.  Clinical Experience with Implantable Scanning Tachycardia Reversion Pacemakers , 1984, Pacing and clinical electrophysiology : PACE.

[17]  E. Sowton Clinical Results with the Tachylog Antitachycardia Pacemaker , 1984, Pacing and clinical electrophysiology : PACE.

[18]  J. Griffin,et al.  The Management of Paroxysmal Tachycardias Using the Cybertach‐60 , 1984, Pacing and clinical electrophysiology : PACE.

[19]  P R Reid,et al.  Automatic Implantable Cardioverter‐Defibrillator Structural Characteristics , 1984, Pacing and clinical electrophysiology : PACE.

[20]  R. Winkle,et al.  Determinants of survival in patients with ventricular tachyarrhythmias. , 1983, The New England journal of medicine.

[21]  J. Maloney,et al.  Programmed ventricular stimulation in management of recurrent ventricular tachycardia. , 1977, Mayo Clinic proceedings.

[22]  H. Wellens,et al.  Electrical Stimulation of the Heart in Patients with Ventricular Tachycardia , 1972, Circulation.

[23]  A. DeMaria,et al.  Treatment of ventricular tachycardia using an automatic scanning extrastimulus pacemaker. , 1984, Journal of the American College of Cardiology.

[24]  J. Fisher,et al.  Role of implantable pacemakers in control of recurrent ventricular tachycardia. , 1982, The American journal of cardiology.

[25]  J. Fisher,et al.  Termination of ventricular tachycardia with bursts of rapid ventricular pacing. , 1978, The American journal of cardiology.