Grouted sleeve connections used in precast reinforced concrete construction – Experimental investigation of a column-to-column joint

Abstract The results of an experimental campaign concerning full-scale tests on precast reinforced concrete column-to-column connections made with grouted sleeve splices are presented. The precast column units had a square cross-section with the side of 500 mm. Eight 20 mm-diameter bars protruding from one unit were grouted into corrugated steel sleeves encased in the other unit. The column-to-column connections were subjected to three monotonic tests (axial tension and four-point bending with and without axial compression) and to two cyclic tests (four-point bending and shear) . In the tension test failure took place far from the interface between the precast units and highlighted the effectiveness of the stress transfer along the splice region. In all other tests, damage developed at the interface between the two units. In the bending tests with and without axial compression significant over-strengths with respect to design resistances computed for equally-reinforced monolithic members were attained. Because of the reduced thickness of the interface between the precast units, the rotation that concentrated at the interface led to a moderate reduction of the global bending stiffness. In the shear test the pure shear capacity of the bars crossing the joint was achieved. The cyclic bending test showed a ductile and stable hysteretic behavior of the connection.

[1]  John F. Stanton,et al.  Application of Accelerated Bridge Construction Connections in Moderate-to-High Seismic Regions , 2011 .

[2]  Marco Savoia,et al.  Damage and collapses in industrial precast buildings after the 2012 Emilia earthquake , 2017 .

[3]  Fabio Minghini,et al.  Observational failure analysis of precast buildings after the 2012 Emilia earthquakes , 2016 .

[4]  Andrea Belleri,et al.  Seismic performance and retrofit of precast concrete grouted sleeve connections , 2012 .

[5]  Kim S. Elliott,et al.  Precast Concrete Structures , 2002 .

[6]  Robert Park,et al.  A perspective on the seismic design opf precast concrete structures in New Zealand , 1995 .

[7]  Negro Paolo,et al.  Design Guidelines for Connections of Precast Structures under Seismic Actions , 2012 .

[8]  A. S. G. Bruggeling,et al.  Prefabrication with Concrete , 1991 .

[9]  E. Vintzēleou,et al.  BEHAVIOR OF DOWELS UNDER CYCLIC DEFORMATIONS. , 1987 .

[10]  Reza Ramezani,et al.  A new ductile moment-resisting connection for precast concrete frames in seismic regions: An experimental investigation , 2014 .

[11]  Paolo Riva Seismic behaviour of precast column-to-foundation grouted sleeve connections , 2006 .

[12]  Viorel Popa,et al.  Experimental testing on emulative connections for precast columns using grouted corrugated steel sleeves , 2015, Bulletin of Earthquake Engineering.

[13]  Andrew H. Buchanan,et al.  Tests on Connections of Earthquake Resisting Precast Reinforced Concrete Perimeter Frames of Buildings , 1995 .

[14]  Paolo Riva,et al.  Cyclic behaviour of a column to foundation joint for concrete precast structures , 2011 .

[15]  J. W. Dougill,et al.  Grouted and dowelled jointed precast concrete columns: behaviour in combined bending and compression , 1988 .

[16]  Matej Fischinger,et al.  Estimation of the cyclic capacity of beam-to-column dowel connections in precast industrial buildings , 2014, Bulletin of Earthquake Engineering.

[17]  Robert Park,et al.  Design of connections of earthquake resisting precast reinforced concrete perimeter frames , 1995 .

[18]  Tatjana Isaković,et al.  Cyclic failure analysis of the beam-to-column dowel connections in precast industrial buildings , 2013 .

[19]  L. X. Zheng Grouted Precast Concrete Column Connections underReversed Cyclic Bending and Compression , 1996 .

[20]  A W Beeby,et al.  CONCISE EUROCODE FOR THE DESIGN OF CONCRETE BUILDINGS. BASED ON BSI PUBLICATION DD ENV 1992-1-1: 1992. EUROCODE 2: DESIGN OF CONCRETE STRUCTURES. PART 1: GENERAL RULES AND RULES FOR BUILDINGS , 1993 .

[21]  Luc Taerwe,et al.  fib model code for concrete structures 2010 , 2013 .