Overview of FACTS devices for wind power plants directly connected to the transmission network

Growing number of wind turbines is changing electricity generation profile all over the world. This brings challenges for power system operation, which was designed and developed around conventional power plants with directly coupled synchronous generators. In result, safety and stability of the electrical network with high wind energy penetration might be compromised. For this reason transmission system operators (TSO) impose more stringent connection requirements on the wind power plant (WPP) owners. On the other hand flexible AC transmission systems (FACTS) devices offer enhancement of grid stability and can facilitate grid code compliance for WPP. In this paper state-of-the-art in FACTS for WPPs with AC connection is given. FACTS devices with their properties are described. HVDC, which in literature is also often recognized as FACTS device, is out of this paper scope. Academic and industrial research in FACTS applicability for WPPs is summarized. Examples of few existing FACTS applications for wind farms are given.

[1]  I. Erlich,et al.  Impact of large offshore wind farms on power system transient stability , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[2]  I. Erlich,et al.  Advanced grid requirements for the integration of wind turbines into the German transmission system , 2006, 2006 IEEE Power Engineering Society General Meeting.

[3]  A.G. Jack,et al.  Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007) , 2007, IEEE Transactions on Power Systems.

[4]  M. Visiers,et al.  WINDFACT®, a solution for the grid code compliance of the windfarms in operation , 2007, 2007 European Conference on Power Electronics and Applications.

[5]  I. Erlich,et al.  Dynamic Behavior of DFIG-Based Wind Turbines during Grid Faults , 2007, 2007 Power Conversion Conference - Nagoya.

[6]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[7]  Aditya P. Jayam,et al.  Improving the dynamic performance of wind farms with STATCOM , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[8]  M. Steurer,et al.  Applying a STATCOM for stability improvement to an existing wind farm with fixed-speed induction generators , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[9]  I. Erlich,et al.  Insert impact of large-scale wind power generation on the dynamic behaviour of interconnected systems , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[10]  Xiao-Ping Zhang,et al.  Flexible AC Transmission Systems: Modelling and Control , 2006 .

[11]  T. Thiringer,et al.  Wind Farms as Reactive Power Ancillary Service Providers—Technical and Economic Issues , 2009, IEEE Transactions on Energy Conversion.

[12]  S. Teleke,et al.  STATCOM with energy storage for smoothing intermittent wind farm power , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[13]  M. Baran,et al.  STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System , 2008, 2006 IEEE PES Power Systems Conference and Exposition.

[14]  Janusz Bialek,et al.  Power System Dynamics: Stability and Control , 2008 .

[15]  G.M. Burt,et al.  The Placement of Facts Devices in Modern Electrical Network , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[16]  A. Beekmann,et al.  Wind energy converters with FACTS Capabilities for optimized integration of wind power into transmission and distribution systems , 2009, 2009 CIGRE/IEEE PES Joint Symposium Integration of Wide-Scale Renewable Resources Into the Power Delivery System.

[17]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[18]  M.S. El-Moursi,et al.  Novel STATCOM Controller for Mitigating SSR and Damping Power System Oscillations in a Series Compensated Wind Park , 2010, IEEE Transactions on Power Electronics.

[19]  R.G. Harley,et al.  Real-Time Implementation of a STATCOM on a Wind Farm Equipped With Doubly Fed Induction Generators , 2006, IEEE Transactions on Industry Applications.

[20]  Bharat Singh,et al.  Wind Power Interconnection into the Power System: A Review of Grid Code Requirements , 2009 .

[21]  M. Rasmussen,et al.  Current Technology for Integrating Wind Farms into Weak Power Grids , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[22]  B. Ronner,et al.  Operational experiences of STATCOMs for wind parks , 2009 .

[23]  R.G. Harley,et al.  Grid Connection Requirements and Solutions for DFIG Wind Turbines , 2008, 2008 IEEE Energy 2030 Conference.

[24]  S.Y. Kim,et al.  The operation experience of KEPCO UPFC , 2005, 2005 International Conference on Electrical Machines and Systems.

[25]  B. Fox,et al.  Grid Integration of Wind Farms Using SVC and STATCOM , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[26]  B. Kehrli,et al.  How the Lake Bonney wind farm met ESCOSA’s, NEMMCO’s, and ElectraNet’s rigorous interconnecting requirements , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.

[27]  Hui Ren,et al.  A Review of FACTS' Practical Consideration and Economic Evaluation , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[28]  I. Erlich,et al.  Interaction of large offshore wind parks with the electrical grid , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[29]  J. H. Provanzana,et al.  Installation, commissioning, and operation of the world's first UPFC on the AEP system , 1998, POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151).