Effect of fixing distal radius fracture with volar locking palmar plates while preserving pronator quadratus.

BACKGROUND L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation. Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons. But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ. Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through mini-incisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus. The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair. METHODS Between September 2010 and April 2012, 65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies). The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications. All surgeries were completed by the same trained team. The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females. We compared the two groups for wrist pain, forearm range of motion, grip strength, perioperative complications and wrist functional recovery score. RESULTS The minimum follow-up for the whole cohort was one year. The differences between the two groups were significant with regard to wrist pain, forearm range of motion, grip strength and wrist function at 1, 2, and 6 weeks postoperatively, but insignificant at 6 and 12 months postoperatively. No significant differences were found in the perioperative complications and radiographs postoperatively. CONCLUSIONS Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates, as this technique can yield better early wrist function and shorten the rehabilitation.

[1]  S. Hershman,et al.  The Effects of Pronator Quadratus Repair on Outcomes After Volar Plating of Distal Radius Fractures , 2013, Journal of orthopaedic trauma.

[2]  H. Kvernmo,et al.  Treatment of distal radius fractures. , 2013, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[3]  S. D. Dodds,et al.  Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. , 2012, The Journal of hand surgery.

[4]  W. Grechenig,et al.  Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? , 2012, The Journal of hand surgery, European volume.

[5]  Hailin Xu,et al.  Clinical effect of distal radius fracture treated with open reduction and internal plate fixation. , 2012, Chinese medical journal.

[6]  M. Keith,et al.  American Academy of Orthopaedic Surgeons clinical practice guideline on: the treatment of distal radius fractures. , 2011, The Journal of bone and joint surgery. American volume.

[7]  T. Oxland,et al.  Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. , 2009, The Journal of hand surgery.

[8]  J. Jupiter,et al.  Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. , 2009, The Journal of bone and joint surgery. American volume.

[9]  C. Dos Remedios,et al.  [Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique]. , 2009, Chirurgie de la main.

[10]  M. Walsh,et al.  Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial. , 2008, The Journal of bone and joint surgery. British volume.

[11]  D. Ruch,et al.  Volar approach to distal radius fractures. , 2008, The Journal of hand surgery.

[12]  E. Harvey,et al.  Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach. , 2008, Techniques in hand & upper extremity surgery.

[13]  Raymond A. Klug,et al.  Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. , 2007, The Journal of hand surgery.

[14]  James A. Johnson,et al.  Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[15]  James A. Johnson,et al.  Influence of the pronator quadratus and supinator muscle load on DRUJ stability. , 2003, The Journal of hand surgery.

[16]  M. Haerle,et al.  Vascular Anatomy of the Palmar Surfaces of the Distal Radius And Ulna: Its Relevance to Pedicled Bone Grafts at the Distal Palmar Forearm , 2003, Journal of hand surgery.

[17]  R. Berger,et al.  The arterial blood supply of the distal radius and ulna and its potential use in vascularized pedicled bone grafts. , 1995, The Journal of hand surgery.

[18]  H W Chin,et al.  Wrist fractures. , 1993, Emergency medicine clinics of North America.

[19]  M. Shrewsbury,et al.  The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint. , 1976, The Journal of hand surgery.