Hemostats, sealants, and adhesives III: a new update as well as cost and regulatory considerations for components of the surgical toolbox

The hemostat, sealant, and adhesive components of the surgical toolbox continue to evolve and enter clinical practice at a rapid rate. The goal of this comprehensive, sequential review is to update these components to include those now available (February 2012) as well as to explore cost and regulatory factors that impact the development and use of these materials. A unique system of definitions for organizing these components based on group, category, and class is used as a means of improving the understanding and appropriate use of these materials. The system will be used here to present the most recent additions to the toolbox, which are evaluated based on safety, efficacy, usability, and cost. These new additions include pooled human plasma fibrinogen and thrombin embedded in an equine collagen patch for cardiac surgical hemostasis, polyethylene glycol (PEG) and human serum albumin for lung surgical pneumostasis, modified PEG and trilysine amine for spinal sealing, octyl and butyl lactoyl cyanoacrylate for vascular sealing, and a variety of octyl and butyl cyanoacrylates with or without dyes and/or polyester mesh for skin closure with the creation of a bacterial barrier. The system of definitions will also be used to clarify key strategies in the current health care environment for reducing costs and for increasing understanding of Food and Drug Administration regulatory decisions for these materials.

[1]  R. Bauernschmitt,et al.  TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  Kee D. Kim,et al.  Polyethylene Glycol Hydrogel Spinal Sealant (DuraSeal Spinal Sealant) as an Adjunct to Sutured Dural Repair in the Spine: Results of a Prospective, Multicenter, Randomized Controlled Study , 2011, Spine.

[3]  Whole Grain Label Statements Guidance for Industry and FDA Staff , 2006 .

[4]  Mong-Wei Lin,et al.  Acute surgical treatment of perforated peptic ulcer in the elderly patients. , 2010, Hepato-gastroenterology.

[5]  T. B. Vaughan,et al.  Intraoperative transfusion of 1 U to 2 U packed red blood cells is associated with increased 30-day mortality, surgical-site infection, pneumonia, and sepsis in general surgery patients. , 2009, Journal of the American College of Surgeons.

[6]  Chris A Rogers,et al.  Increased Mortality, Postoperative Morbidity, and Cost After Red Blood Cell Transfusion in Patients Having Cardiac Surgery , 2007, Circulation.

[7]  G. Ballantyne,et al.  Short-term Changes in Insulin Resistance following Weight Loss Surgery for Morbid Obesity: Laparoscopic Adjustable Gastric Banding versus Laparoscopic Roux-en-Y Gastric Bypass , 2006, Obesity surgery.

[8]  A. Singer,et al.  Evaluation of a new high-viscosity octylcyanoacrylate tissue adhesive for laceration repair: a randomized, clinical trial. , 2003, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[9]  S. Burks,et al.  Hemostats, sealants, and adhesives: components of the surgical toolbox , 2008, Transfusion.

[10]  B. Horowitz,et al.  Estimating the pathogen safety of manufactured human plasma products: application to fibrin sealants and to thrombin , 2008, Transfusion.

[11]  F. Ris,et al.  Population perception of surgical safety and body image trauma: a plea for scarless surgery? , 2011, Surgical Endoscopy.

[12]  A. Wittkowsky Novel Oral Anticoagulants and Their Role in Clinical Practice , 2011, Pharmacotherapy.

[13]  H. Horinouchi,et al.  Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery. , 2002, The Annals of thoracic surgery.

[14]  P. Reilly,et al.  Anemia management program reduces transfusion volumes, incidence of ventilator-associated pneumonia, and cost in trauma patients. , 2006, The Journal of trauma.

[15]  S. Varadarajulu,et al.  Patient perception of natural orifice transluminal endoscopic surgery as a technique for cholecystectomy. , 2008, Gastrointestinal endoscopy.

[16]  S. Burks,et al.  Absorbable Cyanoacrylate as a Vascular Hemostatic Sealant: A Preliminary Trial , 2005, The American surgeon.

[17]  J. Douketis Pharmacologic properties of the new oral anticoagulants: a clinician-oriented review with a focus on perioperative management. , 2010, Current pharmaceutical design.

[18]  V. Martinez,et al.  Transfusion strategy for primary knee and hip arthroplasty: impact of an algorithm to lower transfusion rates and hospital costs. , 2007, British journal of anaesthesia.

[19]  Bantayehu Sileshi,et al.  A Comprehensive Review of Topical Hemostatic Agents: Efficacy and Recommendations for Use , 2010, Annals of surgery.

[20]  Irfan Ahmed,et al.  Patient preferences for surgical techniques: should we invest in new approaches? , 2010, Surgical Endoscopy.

[21]  B. Gil,et al.  Anemia management program reduces transfusion volumes, incidence of ventilator-associated pneumonia, and cost in trauma patients. , 2007, The Journal of trauma.

[22]  C. Ulmer,et al.  Impact of body image on patients’ attitude towards conventional, minimal invasive, and natural orifice surgery , 2011, Langenbeck's Archives of Surgery.

[23]  D. Chang,et al.  Morbidity and mortality associated with antireflux surgery with or without paraesophogeal hernia: a large ACS NSQIP analysis , 2011, Surgical Endoscopy.

[24]  D. Wood,et al.  Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection. , 2004, The Annals of thoracic surgery.

[25]  Stuart J Pocock,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[26]  D. Manas,et al.  Use of Fibrin-Based Sealants and Gelatin-Matrix Hemostats in Laparoscopic Liver Surgery , 2011, Surgical laparoscopy, endoscopy & percutaneous techniques.

[27]  C. Joch The safety of fibrin sealants. , 2003, Cardiovascular surgery.

[28]  G. Huemer,et al.  Effective Wound Closure With a New Two-Component Wound Closure Device (Prineo™) in Excisional Body-Contouring Surgery: Experience in Over 200 Procedures , 2012, Aesthetic Plastic Surgery.

[29]  J. Fratantoni,et al.  Fibrin sealant: summary of a conference on characteristics and clinical uses , 1995, Transfusion.

[30]  I. Stiell,et al.  A randomized, controlled trial comparing a tissue adhesive with suturing in the repair of pediatric facial lacerations. , 1993, Annals of emergency medicine.

[31]  M. Porter The five competitive forces that shape strategy. , 2008, Harvard business review.

[32]  M. Hofmann,et al.  In-Hospital and 6-Month Mortality Rates After Open Elective vs Open Emergent Colectomy in Patients Older Than 80 Years , 2011, Diseases of the colon and rectum.

[33]  J. Altman,et al.  Topical Hemostatic Agents: A Review , 2008, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[34]  G. Mcgwin,et al.  Transfusions in the less severely injured: does age of transfused blood affect outcomes? , 2008, The Journal of trauma.

[35]  I. Stiell,et al.  A randomized trial comparing octylcyanoacrylate tissue adhesive and sutures in the management of lacerations. , 1997, JAMA.

[36]  Takayuki Takubo,et al.  Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery , 2000, British journal of haematology.

[37]  J. Albes,et al.  The use of Tachosil surgical patch or fibrin glue in coronary artery surgery does not affect quality of anastomosis or provoke postoperative adhesions in pigs. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[38]  D. Toriumi,et al.  Use of octyl-2-cyanoacrylate for skin closure in facial plastic surgery. , 1998, Plastic and reconstructive surgery.

[39]  T. Mihaljevic,et al.  Duration of red-cell storage and complications after cardiac surgery. , 2008, The New England journal of medicine.

[40]  E. Castle,et al.  Transperitoneal versus extraperitoneal robotic-assisted radical prostatectomy: is one better than the other? , 2006, Urology.

[41]  S. Burks,et al.  State-of-the-Art Review: Hemostats, Sealants, and Adhesives II: Update As Well As How and When to Use the Components of the Surgical Toolbox , 2010, Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis.

[42]  J. Fildes,et al.  Randomized prospective study comparing conventional subcuticular skin closure with Dermabond skin glue after saphenous vein harvesting. , 2009, The Annals of thoracic surgery.

[43]  S. Ikramuddin,et al.  Bariatric Surgery Outcomes in the Elderly: An ACS NSQIP Study , 2011, Journal of Gastrointestinal Surgery.

[44]  A. Lumsden,et al.  Prospective randomized study evaluating an absorbable cyanoacrylate for use in vascular reconstructions. , 2006, Journal of vascular surgery.