Control Strategy and Operation Optimization of CCHP with Solar Integrated Utilization

With characteristics of high efficiency and less pollution, combined cooling heating and power system, which can realize the energy cascade utilization, will become the development trend of distributed energy supply system in the future. Under this circumstance, this paper aims to design a co-supply system combining solar integrated utilization of PV/PT technologies with thermally activated technologies. The comprehensive evaluation index is obtained by constructed methods of judgment matrix considering energy conservation, environmental protection and economy integrally. The paper proposes three different control strategies of two different operation modes of OPH and OHP respectively. The effectiveness and feasibility of the proposed model were verified by system analysis of optimal refrigerating capacity ratio, optimal PV power generation capacity and the evaluation of control strategies.

[1]  Zhang Xiao-hui Energy Consumption Performance of Combined Heat Cooling and Power System , 2007 .

[2]  J. Y. Wu,et al.  Theoretical research of a silica gel–water adsorption chiller in a micro combined cooling, heating and power (CCHP) system , 2009 .

[3]  Sheng Li,et al.  Multi-objective optimal operation strategy study of micro-CCHP system , 2012, Energy.

[4]  Zhang Zhengkai Three-phase Probabilistic Power Flow Calculation in Distribution Systems with Multiple Unsymmetrical Grid-connected Photovoltaic Systems , 2012 .

[5]  Wu Zhi,et al.  Economic and Optimal Operation of a Combined Heat and Power Microgrid with Renewable Energy Resources , 2011 .

[6]  Zhou Chengke,et al.  Environmental Benefits Analysis of Distributed Generation , 2008 .

[7]  Ali Keshavarz,et al.  Sizing the prime mover of a residential micro-combined cooling heating and power (CCHP) system by multi-criteria sizing method for different climates , 2013 .

[8]  You-Yin Jing,et al.  Optimization of capacity and operation for CCHP system by genetic algorithm , 2010 .

[9]  Hoseyn Sayyaadi,et al.  Application of the multi-objective optimization and risk analysis for the sizing of a residential small-scale CCHP system , 2013 .

[10]  Ali Keshavarz,et al.  Energy and exergy analyses of a micro-steam CCHP cycle for a residential building , 2012 .

[11]  Yang Shi,et al.  A Novel Optimal Operational Strategy for the CCHP System Based on Two Operating Modes , 2012, IEEE Transactions on Power Systems.

[12]  Heejin Cho,et al.  A probability constrained multi-objective optimization model for CCHP system operation decision support , 2014 .

[13]  Fang Fang,et al.  A new operation strategy for CCHP systems with hybrid chillers , 2012 .

[14]  Ming Qu,et al.  Energy, environmental, and economic evaluation of a CCHP system for a data center based on operational data , 2013 .