An efficiency experimented wind turbine emulator linked to transmission line model 380 kV

In this paper, the author investigates an experimental wind turbine emulator linked to a transmission line model 380 kV. Before presenting and analyzing the experimental results that deals with the voltages, the Ferranti effect, the active and the reactive powers at the sending end and the receiving end with different kinds of loads, the author presents firstly a theoretical study dealing with the model of the wind turbine, the salient synchronous generator and the transmission line. The Ferranti effect and the power analysis are also presented. Theoretical study and experimental results are benefits and advantageous.

[1]  Lassaad Sbita,et al.  An Advanced DPC-Self Excited Induction Generator Drive Scheme for an Isolated Wind Turbine Boost System , 2012 .

[2]  Neven Bulić,et al.  A Comparison of Advanced Control Structures for Synchronous Generator Excitation Control , 2010 .

[3]  Francisco de Leon,et al.  Long Duration Overvoltages due to Current Backfeeding in Secondary Networks , 2013, IEEE Transactions on Power Delivery.

[4]  Mohammad Monfared,et al.  Two fuzzy-based direct power control strategies for doubly-fed induction generators in wind energy conversion systems , 2013 .

[5]  Roberto Benato,et al.  Operating capability of ac EHV mixed lines with overhead and cables links , 2008 .

[6]  F.M. Gatta,et al.  Very long EHV cables and mixed overhead-cable lines. Steady-state operation , 2005, 2005 IEEE Russia Power Tech.

[7]  U. Eminoglu,et al.  A new power flow method for radial distribution systems including voltage dependent load models , 2005 .

[8]  Roberto Benato,et al.  Operating capability of long AC EHV transmission cables , 2005 .

[9]  Andoni Urtasun,et al.  Modeling of small wind turbines based on PMSG with diode bridge for sensorless maximum power tracking , 2013 .

[10]  Noureddine Hidouri Power Control Applied to a Grid Connected Fuzzy-MPPT Controlled Photovoltaic System , 2014 .

[11]  Marcos Donolo,et al.  Software for calculation of electric power systems parameters , 2003, Comput. Electr. Eng..

[12]  Shailaja Kurode,et al.  Discrete sliding mode control strategy for direct real and reactive power regulation of wind driven DFIG , 2013 .

[13]  Alberto Geri,et al.  Steady-state operating conditions of very long EHVAC cable lines , 2011 .

[14]  Ali H. Kasem Alaboudy,et al.  Converter controls and flicker study of PMSG-based grid connected wind turbines , 2013 .

[15]  Noureddine Hidouri A Fuzzy Controlled Scheme for an Isolated Hybrid MPPT-Photovoltaic Diesel-PMSG System , 2014 .

[16]  S. A. Deraz,et al.  A new control strategy for a stand-alone self-excited induction generator driven by a variable speed wind turbine , 2013 .

[17]  Marco Marelli,et al.  THE NEW TURBIGO-RHO 380 kV TRANSMISSION LINE: AN EXAMPLE OF THE USE OF UNDERGROUND XLPE CABLES IN A MESHED TRANSMISSION GRID , 2006 .

[18]  N. Petcharaks,et al.  A study of Ferranti and energization overvoltages case of 500 kV line in Thailand , 1999 .

[19]  Damasio Fernandes,et al.  Fault location on transmission lines little longer than half-wavelength , 2014 .