Pneumatic paracorporeal ventricular assist device in infants and children: initial Stanford experience.

BACKGROUND Mechanical circulatory support with the Berlin Heart EXCOR pediatric ventricular assist device (VAD) has been used successfully in Europe for children with cardiac failure. Eighty-seven devices have been placed in North America through February 2007. We describe our single-center experience in 8 children. METHODS Eight children (ages 4 to 55 months), with median weight of 9.6 kg and body surface area of 0.48 m(2), received the Berlin Heart VAD as a bridge to transplantation. All patients were in cardiogenic shock requiring multiple inotropes. Primary diagnoses were idiopathic dilated cardiomyopathy (n = 4), congenital heart disease (n = 3) and restrictive cardiomyopathy (n = 1). After device insertion, all patients were treated with an anti-coagulant (heparin or coumadin) and one or more platelet inhibitors (aspirin with clopidogrel or dipyridamole). RESULTS Five patients received support with a left ventricular assist device (LVAD) and 3 with a biventricular device (BiVAD). Duration of support ranged from 2 to 234 days (median 57 days). Five patients (63%) were successfully bridged to transplantation; of these, 4 were discharged home and 1 died from early graft failure. Five patients developed post-operative neurologic events. Of these 5 events, 4 could be explained by embolism or hemorrhage. Device exchange was performed in 4 patients in the intensive care unit. CONCLUSIONS In selected children, the Berlin Heart VAD can be used as a bridge to transplantation. In contrast to the published European experience, neurologic events occur frequently. Anti-coagulation and platelet inhibition strategies continue to evolve. Device exchange is technically feasible at the bedside and should be considered at the earliest visualization of thrombus formation.

[1]  B. Clark,et al.  Prolonged extracorporeal membrane oxygenation as a bridge to cardiac transplantation. , 2000, The Annals of thoracic surgery.

[2]  R. Carroll,et al.  A novel modification of the Thrombelastograph assay, isolating platelet function, correlates with optical platelet aggregation. , 2004, The Journal of laboratory and clinical medicine.

[3]  T. Myers,et al.  Management of air embolism during HeartMate XVE exchange. , 2007, Texas Heart Institute journal.

[4]  J. Copeland,et al.  Pediatric bridge to heart transplantation: application of the Berlin Heart, Medos and Thoratec ventricular assist devices. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[5]  P. D. del Nido,et al.  Mechanical circulatory support in children with cardiac disease. , 1999, The Journal of thoracic and cardiovascular surgery.

[6]  C. Fraser,et al.  Preliminary experience with the MicroMed DeBakey pediatric ventricular assist device. , 2006, Seminars in thoracic and cardiovascular surgery. Pediatric cardiac surgery annual.

[7]  Marvin J Slepian,et al.  Total artificial hearts: bridge to transplantation. , 2003, Cardiology clinics.

[8]  R. Hetzer,et al.  Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients. , 2006, The Annals of thoracic surgery.

[9]  R. Bartlett,et al.  Extracorporeal Life Support Registry Report 1995. , 1997, ASAIO journal.

[10]  R. Hetzer,et al.  Pneumatic pulsatile ventricular assist devices in children under 1 year of age. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[11]  R. Hetzer,et al.  Technology Insight: use of ventricular assist devices in children , 2006, Nature Clinical Practice Cardiovascular Medicine.

[12]  H. Reul,et al.  Clinical experience with the MEDOS HIA-VAD system in infants and children: a preliminary report. , 1997, The Annals of thoracic surgery.

[13]  B. Reitz,et al.  Successful bridge to transplant using the Berlin Heart left ventricular assist device in a 3-month-old infant. , 2006, The Annals of thoracic surgery.

[14]  B. Clark,et al.  Use of extracorporeal membrane oxygenation in pediatric thoracic organ transplantation. , 2002, The Journal of thoracic and cardiovascular surgery.

[15]  M. Elliott,et al.  Cardiac ECMO for biventricular hearts after paediatric open heart surgery , 2004, Heart.

[16]  D. Farrar,et al.  Current Clinical Status of Pulsatile Pediatric Circulatory Support , 2002, ASAIO journal.

[17]  R. Hetzer,et al.  Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children. , 1998, The Annals of thoracic surgery.

[18]  P. Rycus,et al.  Extracorporeal Life Support Registry Report 2004 , 2005, ASAIO journal.

[19]  D. Farrar,et al.  Thoratec Ventricular Assist Devices in Pediatric Patients: Update on Clinical Results , 2005, ASAIO journal.

[20]  S. Bratton,et al.  Outcome of pediatric patients treated with extracorporeal life support after cardiac surgery. , 2003, The Annals of thoracic surgery.

[21]  J. Copeland,et al.  Multicenter experience with the thoratec ventricular assist device in children and adolescents. , 2001, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[22]  H. Scheld,et al.  Pediatric Assist With the Medos and Excor Systems in Small Children , 2006, ASAIO journal.

[23]  T. Spray,et al.  Risk factors for mortality in 137 pediatric cardiac intensive care unit patients managed with extracorporeal membrane oxygenation* , 2004, Critical care medicine.