Joystick use for virtual power wheelchair driving in individuals with tremor: pilot study.

People with disabilities such as multiple sclerosis and Parkinson's disease have difficulty operating conventional movement-sensing joysticks (MSJs) because of varying levels of tremor. We developed an isometric joystick (IJ) that has performed as well as a conventional MSJ when used by persons with upper-limb impairments in real and virtual wheelchair driving tasks. The Weighted-Frequency Fourier Linear Combiner (WFLC) filter has been used to cancel tremor effectively in microsurgery. In this study, we compared an MSJ, IJ, and IJ with the WFLC filter in individuals performing a virtual driving task. Although the WFLC filter did not improve driving performance in this study, the IJ without a filter yielded better results than the conventional MSJ and thus may be a potential alternative to the MSJ in minimizing the effects of tremor.

[1]  Shirley G Fitzgerald,et al.  Comparison of virtual and real electric powered wheelchair driving using a position sensing joystick and an isometric joystick. , 2002, Medical engineering & physics.

[2]  R. N. Stiles,et al.  POWER SPECTRAL ANALYSIS OF FINGER ACCELERATION TREMOR. , 1964, Journal of applied physiology.

[3]  Nitish V. Thakor,et al.  Adaptive Fourier modeling for quantification of tremor 1 Funding provided by National Institute on Disability and Rehabilitation Research (grant number H133G30064). 1 , 1997, Journal of Neuroscience Methods.

[4]  Bernard D. Adelstein,et al.  Manual control interfaces for the tremor-disabled , 1983 .

[5]  R. N. Stiles Mechanical and neural feedback factors in postural hand tremor of normal subjects. , 1980, Journal of neurophysiology.

[6]  L Fehr,et al.  Adequacy of power wheelchair control interfaces for persons with severe disabilities: a clinical survey. , 2000, Journal of rehabilitation research and development.

[7]  R N Stiles,et al.  A viscoelastic-mass mechanism as a basis for normal postural tremor. , 1974, Journal of applied physiology.

[8]  R. N. Stiles Frequency and displacement amplitude relations for normal hand tremor. , 1976, Journal of applied physiology.

[9]  W. Weiner Parkinson’s Disease and Movement Disorders , 2000, Current Clinical Practice.

[10]  Rory A. Cooper,et al.  Force sensing control for electric powered wheelchairs , 2000, IEEE Trans. Control. Syst. Technol..

[11]  R. N. Stiles,et al.  Mechanical factors in human tremor frequency. , 1967, Journal of applied physiology.

[12]  M J Rosen,et al.  Evaluating manual control devices for those with tremor disability. , 1987, Journal of rehabilitation research and development.

[13]  M. Boninger,et al.  Advancements in Power Wheelchair Joystick Technology: Effects of Isometric Joysticks and Signal Conditioning on Driving Performance , 2006, American journal of physical medicine & rehabilitation.

[14]  H. Freund,et al.  Stability of frequency during long-term recordings of hand tremor. , 1987, Electroencephalography and clinical neurophysiology.

[15]  N.V. Thakor,et al.  Adaptive cancelling of physiological tremor for improved precision in microsurgery , 1998, IEEE Transactions on Biomedical Engineering.

[16]  R N Stiles Acceleration time series resulting from repetitive extension-flexion of the hand. , 1975, Journal of applied physiology.

[17]  Rory A. Cooper,et al.  Intelligent control of power wheelchairs , 1995 .

[18]  Rory A. Cooper,et al.  Analysis of position and isometric joysticks for powered wheelchair driving , 2000, IEEE Transactions on Biomedical Engineering.