Dynamic Friction-Based Force Feedback for Tendon- Sheath Mechanism in NOTES System

Tendon-sheath mechanism (TSM) is commonly used in flexible endoscopic systems because of its high flexibility, light weight, and easy transmission. Due to the size constraints and sterilization problems, traditional sensors cannot be placed at the tool tips of robotic arms. In addition, nonlinear friction and backlash hysteresis cause many challenges to predict the desired force when the system inside the human's body. It is extremely difficult to provide the force information to haptic devices and subsequently to the users. In this paper, a new scheme of dynamic friction model for a pair of TSMs is proposed to estimate the force at distal end of endoscopic system. In comparison with current approaches in the literature, our model is able to provide continuous force information. The model is able to predict distal force with any sheath shapes. An experimental setup is designed to measure the friction force in the TSM. Finally, the validity of the proposed model approach is confirmed with a good agreement between the estimated values and real experimental data.

[1]  Tegoeh Tjahjowidodo,et al.  An investigation of friction-based tendon sheath model appropriate for control purposes , 2014 .

[2]  Carlos Canudas de Wit,et al.  A new model for control of systems with friction , 1995, IEEE Trans. Autom. Control..

[3]  Allison M. Okamura,et al.  Haptics for Robot-Assisted Minimally Invasive Surgery , 2007, ISRR.

[4]  Xingsong Wang,et al.  The Design of a Tendon-Sheath-Driven Robot , 2008, 2008 15th International Conference on Mechatronics and Machine Vision in Practice.

[5]  Tegoeh Tjahjowidodo,et al.  Nonlinear Modeling and Parameter Identification of Dynamic Friction Model in Tendon Sheath for Flexible Endoscopic Systems , 2013, ICINCO.

[6]  Melanie Mitchell,et al.  An introduction to genetic algorithms , 1996 .

[7]  Arthur E. Quaid,et al.  Haptic information displays for computer-assisted surgery , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[8]  Paolo Dario,et al.  Tendon sheath analysis for estimation of distal end force and elongation , 2009, 2009 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[9]  B. Yao,et al.  Modeling of a closed loop cable-conduit transmission system , 2008, 2008 IEEE International Conference on Robotics and Automation.

[10]  R. Förster,et al.  Thoracoscopy versus thoracotomy: a prospective comparison of trauma and quality of life , 2002, Langenbeck's Archives of Surgery.

[11]  Gianluca Palli,et al.  OPTIMAL CONTROL OF TENDON-SHEATH TRANSMISSION SYSTEMS , 2006 .

[12]  Pietro Valdastri,et al.  Tendon sheath analysis for estimation of distal end force and elongation , 2009, AIM 2009.

[13]  Hendrik Van Brussel,et al.  Friction characterization and compensation in electro-mechanical systems , 2007 .

[14]  Tegoeh Tjahjowidodo,et al.  Dynamic friction model for tendon-sheath actuated surgical robots : modelling and stability analysis , 2013 .

[15]  Tegoeh Tjahjowidodo,et al.  Hysteresis modeling and position control of tendon-sheath mechanism in flexible endoscopic systems , 2014 .

[16]  Masakatsu G. Fujie,et al.  Haptic feedback control in medical robots through fractional viscoelastic tissue model , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  Vincent Hayward,et al.  Haptic interfaces and devices , 2004 .

[18]  J. Bodner,et al.  First experiences with the da Vinci operating robot in thoracic surgery. , 2004, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[19]  Philippe Zanne,et al.  Robotic Assistance to Flexible Endoscopy by Physiological-Motion Tracking , 2011, IEEE Transactions on Robotics.

[20]  Makoto Kaneko,et al.  Input-dependent stability of joint torque control of tendon-driven robot hands , 1992, IEEE Trans. Ind. Electron..

[21]  Chen Lin,et al.  Modeling of the tendon-sheath actuation system , 2012, 2012 19th International Conference on Mechatronics and Machine Vision in Practice (M2VIP).

[22]  Bin Yao,et al.  Modeling of Transmission Characteristics Across a Cable-Conduit System , 2010, IEEE Transactions on Robotics.

[23]  Kazuo Tanie,et al.  A new consideration on tendon-tension control system of robot hands , 1991, Proceedings. 1991 IEEE International Conference on Robotics and Automation.

[24]  F. Ikhouane,et al.  Systems with Hysteresis: Analysis, Identification and Control Using the Bouc-Wen Model , 2007 .

[25]  Wang Xingsong,et al.  The Design of a Tendon-Sheath-Driven Robot , 2008 .

[26]  M. Meng,et al.  ROBOTICS IN NATURAL ORIFICE TRANSLUMINAL ENDOSCOPIC SURGERY , 2013 .

[27]  JOURNAL OF SOUND AND VIBRATION , 1998 .

[28]  M. Aoe,et al.  Pulmonary function, postoperative pain, and serum cytokine level after lobectomy: a comparison of VATS and conventional procedure. , 2001, The Annals of thoracic surgery.

[29]  F. Ikhouane,et al.  Variation of the hysteresis loop with the Bouc–Wen model parameters , 2007 .

[30]  Dorothea Heiss-Czedik,et al.  An Introduction to Genetic Algorithms. , 1997, Artificial Life.

[31]  M. Kaneko,et al.  Basic considerations on transmission characteristics for tendon drive robots , 1991, Fifth International Conference on Advanced Robotics 'Robots in Unstructured Environments.

[32]  A. Okamura Haptic feedback in robot-assisted minimally invasive surgery , 2009, Current opinion in urology.

[33]  Gianluca Palli,et al.  Model and control of tendon-sheath transmission systems , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..