A Head Mountable Deep Brain Stimulation Device for Laboratory Animals

Deep brain stimulation has emerged as an effective method to treat certain medical conditions. Electrical charges are injected into the target tissue through a conducting electrode exciting the tissue. A variety of DBS devices have been developed based on different operation principles. Majority of these devices, however, employ complex circuitry and are bulky. In clinical trials, laboratory animals need to freely move around and perform activities whilst receiving brain stimulation for days. This paper presents a simple lightweight head mountable deep brain stimulation device that can be carried by the animal during the course of a clinical trial. The device produces continuous current pulses of specific characteristics. It employs passive charge balancing to minimize undesirable effects on the target tissue. The device is constructed and its performance tested.

[1]  Maurits Ortmanns,et al.  An experimental study on passive charge balancing , 2009 .

[2]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[3]  Daichi Horimai,et al.  Circuit design for Brain Stimulation and transmitter sensing , 2010, 2010 IEEE Long Island Systems, Applications and Technology Conference.

[4]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[5]  Kenneth Horch,et al.  A charge-balanced pulse generator for nerve stimulation applications , 2008, Journal of Neuroscience Methods.

[6]  Maurits Ortmanns,et al.  An Active Approach for Charge Balancing in Functional Electrical Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[7]  Sherwin E. Hua,et al.  Deep Brain Stimulation: An Evolving Technology , 2008, Proceedings of the IEEE.

[8]  Hong Jia,et al.  PRECLINICAL STUDY: Chronic deep brain stimulation in the rat nucleus accumbens and its effect on morphine reinforcement , 2008, Addiction biology.

[9]  Maurits Ortmanns,et al.  Charge Balancing in Functional Electrical Stimulators: A Comparative Study , 2007, 2007 IEEE International Symposium on Circuits and Systems.

[10]  C. McIntyre,et al.  Differences among implanted pulse generator waveforms cause variations in the neural response to deep brain stimulation , 2007, Clinical Neurophysiology.

[11]  T. Stieglitz,et al.  Recent advances in charge balancing for functional electrical stimulation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Thomas Stieglitz,et al.  A voltage-controlled current source with regulated electrode bias-voltage for safe neural stimulation , 2008, Journal of Neuroscience Methods.