Automatic retinal interest evaluation system (ARIES)

In recent years, there has been increasing interest in the use of automatic computer-based systems for the detection of eye diseases such as glaucoma, age-related macular degeneration and diabetic retinopathy. However, in practice, retinal image quality is a big concern as automatic systems without consideration of degraded image quality will likely generate unreliable results. In this paper, an automatic retinal image quality assessment system (ARIES) is introduced to assess both image quality of the whole image and focal regions of interest. ARIES achieves 99.54% accuracy in distinguishing fundus images from other types of images through a retinal image identification step in a dataset of 35342 images. The system employs high level image quality measures (HIQM) to perform image quality assessment, and achieves areas under curve (AUCs) of 0.958 and 0.987 for whole image and optic disk region respectively in a testing dataset of 370 images. ARIES acts as a form of automatic quality control which ensures good quality images are used for processing, and can also be used to alert operators of poor quality images at the time of acquisition.

[1]  T. Wong,et al.  Rationale and Methodology for a Population-Based Study of Eye Diseases in Malay People: The Singapore Malay Eye Study (SiMES) , 2007, Ophthalmic epidemiology.

[2]  Langis Gagnon,et al.  Automatic visual quality assessment in optical fundus images , 2001 .

[3]  J. Olson,et al.  Automated assessment of diabetic retinal image quality based on clarity and field definition. , 2006, Investigative ophthalmology & visual science.

[4]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[5]  Bram van Ginneken,et al.  Image structure clustering for image quality verification of color retina images in diabetic retinopathy screening , 2006, Medical Image Anal..

[6]  Martin Kraus,et al.  Automatic no-reference quality assessment for retinal fundus images using vessel segmentation , 2013, Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems.

[7]  Patricia Ladret,et al.  The blur effect: perception and estimation with a new no-reference perceptual blur metric , 2007, Electronic Imaging.

[8]  Tin Aung,et al.  Associations of iris structural measurements in a Chinese population: the Singapore Chinese Eye Study. , 2013, Investigative ophthalmology & visual science.

[10]  K. W. Tobin,et al.  Elliptical local vessel density: A fast and robust quality metric for retinal images , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.