Use of the Microangiographic Fluoroscope for Coiling of Intracranial Aneurysms

BACKGROUND Neurointervention is an ever-evolving specialty with tools including microcatheters, microwires, and coils that allow treatment of pathological conditions in increasingly smaller intracranial arteries, requiring increasing accuracy. As endovascular tools evolve, so too should the imaging. OBJECTIVE To detail the use of microangiography performed with a novel fluoroscope during coiling of intracranial aneurysms in 2 separate patients and discuss the benefits and potential limitations of the technology. METHODS The microangiographic fluoroscope (MAF) is an ultra high-resolution x-ray detector with superior resolution over a small field of view. The MAF can be incorporated into a standard angiographic C-arm system for use during endovascular procedures. RESULTS The MAF was useful for improved visualization during endovascular coiling of 2 unruptured intracranial aneurysms, without adding significant time to the procedure. No significant residual aneurysm filling was identified post-coiling, and no complications occurred. CONCLUSION The MAF is a high-resolution detector developed for use in neurointerventional cases in which superior image quality over a small field of view is required. It has been used with success for coiling of 2 unruptured aneurysms at our institution. It shows promise as an important tool in improving the accuracy with which neurointerventionists can perform certain intracranial procedures. ABBREVIATIONS AP: anteroposterior CT: computed tomography CTA: CT angiography DSA: digital subtraction angiography FOV: field of view ICA: internal carotid artery MAF: microangiographic fluoroscope

[1]  M. G. Ort,et al.  Absorption Edge Fluoroscopy Using Quasi‐monoenergetic X‐ray Beams* , 1973, Investigative radiology.

[2]  Maximilian F Reiser,et al.  Advances in digital radiography: physical principles and system overview. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  K. Hoffmann,et al.  Rotational micro-CT using a clinical C-arm angiography gantry. , 2008, Medical physics.

[4]  C Keleshis,et al.  Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions , 2009, Medical Imaging.

[5]  C A Mistretta,et al.  Digital angiography: a perspective. , 1981, Radiology.

[6]  Stephen Rudin,et al.  Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system , 2005, SPIE Medical Imaging.

[7]  K. Gill Evaluation of effective dose in region-of-interest neuroimaging , 2010 .

[8]  Stephen Rudin,et al.  Study of the generalized MTF and DQE for a new microangiographic system , 2004, SPIE Medical Imaging.

[9]  Daniel R. Bednarek,et al.  Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics , 2010, Medical Imaging.

[10]  Daniel R. Bednarek,et al.  Generalized objective performance assessment of a new high-sensitivity microangiographic fluoroscopic (HSMAF) imaging system , 2008, SPIE Medical Imaging.

[11]  K. Hoffmann,et al.  Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system. , 2005, Medical physics.