Combined effect of energy efficiency measures and thermal adaptation on air conditioned building in warm climatic conditions of India

Abstract This study evaluates improvement in energy efficiency of an air conditioned building block employing energy conservation measures (ECMs) recommended by Indian Energy Conservation Building Code 2007 (ECBC) through a prescriptive route. First part evaluates energy savings by implementing five ECMs of envelope independently and two combinations of ECMs keeping constant thermostat setting throughout the year. In the second part of the study same ECMs are considered to the subject building model allowing thermostat settings as per thermal adaptation resulting from change in outdoor temperature. Actual measurements were taken and simulation model was fine-tuned. Annual energy consumption of building is used to evaluate the effect of individual ECMs and their combinations on both part of the study, i.e. fixed thermostat and adaptive thermostat settings. The simulation result shows that together with combination of all ECMs recommended by ECBC, small buildings can save up to 40% energy consumption as compared to buildings built with conventionally practised specifications of India. Effect of thermal adaptation itself offers up to 16% energy saving opportunity in small buildings considering adaptive thermostat settings. The potential of energy conservation through ECMs suggested by ECBC and adaptive set point gets significantly reduced for large size buildings having high internal heat gains.

[1]  H. Akbari,et al.  Cooling energy savings potential of reflective roofs for residential and commercial buildings in the United States , 1999 .

[2]  Mtr Jayasinghe,et al.  Thermal comfort temperature range for factory workers in warm humid tropical climates , 2008 .

[3]  Omer Kaynakli,et al.  A review of the economical and optimum thermal insulation thickness for building applications , 2012 .

[4]  K. W. Mui,et al.  Adaptive comfort temperature model of air-conditioned building in Hong Kong , 2003 .

[5]  H. Akbari,et al.  Estimating the effect of using cool coatings on energy loads and thermal comfort in residential buildings in various climatic conditions , 2007 .

[6]  Joseph Khedari,et al.  Thermal comfort standards for air conditioned buildings in hot and humid Thailand considering additional factors of acclimatization and education level , 2005 .

[7]  Liwei Tian,et al.  Optimum insulation thickness of residential roof with respect to solar-air degree-hours in hot summe , 2011 .

[8]  A. Auliciems,et al.  Airconditioning in Australia I – human thermal factors , 1986 .

[9]  Wilhelm A. Friess,et al.  Wall insulation measures for residential villas in Dubai: A case study in energy efficiency , 2012 .

[10]  H. Radhi,et al.  Can envelope codes reduce electricity and CO2 emissions in different types of buildings in the hot climate of Bahrain , 2009 .

[11]  Luis Pérez-Lombard,et al.  A review on buildings energy consumption information , 2008 .

[12]  Jyotirmay Mathur,et al.  Calibrated simulation for estimating energy savings by the use of cool roof in five Indian climatic zones , 2011 .

[13]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[14]  Preecha Tummu,et al.  Thermal performance and cost effectiveness of wall insulation under Thai climate , 2012 .