Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.

Currently in United States, there are no clinically-applicable hollow fiber extracorporeal membrane oxygenation (ECMO) oxygenators available. Therefore, our laboratory is in the process of developing a silicone hollow fiber membrane oxygenator for long-term ECMO usage. This oxygenator incorporates an ultrathin silicone hollow fiber. At this time, a specially-modified blood flow distributor (one chamber distributor) is centered in the module to prevent blood stagnation. An ex vivo long-term durability test for ECMO was performed using a healthy miniature calf for 2 weeks. Venous blood was drained from the left jugular vein of a calf, passed through the oxygenator and infused into the left carotid artery using a Gyro C1E3 centrifugal blood pump. A successful 2-week ex vivo experiment was performed. The O2 and CO2 gas transfer rates were maintained at the same value of 40 m/min at a blood flow rate of 1 L/min flow and V/Q=3 (V=gas flow rate; Q=blood flow rate). The plasma free hemoglobin was maintained around 5 mg/dl. After the experiment, no blood clot formation was observed in the module and no abnormal necropsy findings were found. These data suggest that the performance of this newly-improved oxygenator was stable, reliable, and acceptable for long-term ECMO.

[1]  R. Bartlett,et al.  Current status of extracorporeal membrane oxygenation for severe respiratory failure. , 2008, Artificial organs.

[2]  J. Linneweber,et al.  Preclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study. , 2002, Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia.

[3]  J. Linneweber,et al.  Gas transfer performance of a hollow fiber silicone membrane oxygenator: ex vivo study. , 2001, Artificial organs.

[4]  J. Linneweber,et al.  Development of a new hollow fiber silicone membrane oxygenator: in vitro study. , 2001, Artificial organs.

[5]  J. Linneweber,et al.  Preclinical Evaluation of a Hollow Fiber Silicone Membrane Oxygenator for Extracorporeal Membrane Oxygenator Application , 2000, ASAIO journal.

[6]  Y Nosé,et al.  Development of a silicone hollow fiber membrane oxygenator for ECMO application. , 1998, ASAIO journal.

[7]  Y. Niimi,et al.  Protein Adsorption and Platelet Adhesion on the Surface of an Oxygenator Membrane , 1997, ASAIO journal.

[8]  I. Sakuma,et al.  Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber. , 1996, ASAIO journal (1992).

[9]  Y Ohara,et al.  Does hematocrit affect in vitro hemolysis test results? Preliminary study with Baylor/NASA prototype axial flow pump. , 1994, Artificial organs.

[10]  R H Bartlett,et al.  Plasma leakage through microporous membranes. Role of phospholipids. , 1992, ASAIO journal.

[11]  J. Gaylor,et al.  An in Vitro Technique to assess Oxygenator Potential for Respiratory Failure Therapies , 1991, The International journal of artificial organs.

[12]  A. Tortolani,et al.  Bloodless Testing for Microporous Membrane Oxygenator Failure: A Preliminary Study , 1991, The International journal of artificial organs.

[13]  A. Kashefi,et al.  Technical aspects of plasma leakage prevention in microporous capillary membrane oxygenators. , 1989, ASAIO transactions.

[14]  S. Kundu,et al.  Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump. , 1988, ASAIO transactions.

[15]  W. Zapol,et al.  Extended term (to 16 days) partial extracorporeal blood gas exchange with the spiral membrane lung in unanesthetized lambs. , 1971, Transactions - American Society for Artificial Internal Organs.