Optimal Ground Tube Length for Cooling of Electronics Shelters

This paper presents a theoretical, numerical, and experimental study to investigate the possibility of optimizing the configuration (geometry) of underground heat exchangers for maximum heat transfer. The first part of the study identifies a novel fundamental optimization principle for maximizing heat transfer between a tube and its surroundings, which is expected to be present in any buried tube heat exchanger design. The second part presents a practical application of the fundamental principle: a simplified physical model to determine the temperature field inside an electronics shelter that uses an earth-air heat exchanger and the soil as a heat sink. A volume elements methodology is employed to obtain a system of ordinary differential equations with time as the independent variable that combines principles of classical thermodynamics and heat transfer. This allows the computation of the temperature and relative humidity fields at every instant inside the shelter. The numerical results obtained with the proposed model are validated by means of direct comparison with experimental temperature and relative humidity measurements. It is shown that the tube length can be optimized such that the maximum temperature reached inside the shelter is minimal. The results also demonstrate the potential of the utilization of buried tubes for cooling electronic packages. Since accuracy and low computational time are combined, the model is shown to be efficient and could be used as a tool for simulation, design, and optimization of electronic packages cooled by underground heat exchangers.

[1]  Arnold Janssens,et al.  Thermo-hydraulic design of earth-air heat exchangers , 2003 .

[2]  Lingen Chen,et al.  Ground heat exchanger temperature distribution analysis and experimental verification , 2002 .

[3]  P. D. Metz,et al.  The Use of Ground-Coupled Tanks in Solar-Assisted Heat-Pump Systems , 1982 .

[4]  Josua P. Meyer,et al.  Effectiveness of a municipal ground-coupled reversible heat pump system compared to an air-source system , 1998 .

[5]  V. D. Baxter,et al.  An optimized ground-coupled heat pump system design for northern climate applications , 1985 .

[6]  J. M. Coulson,et al.  Heat Transfer , 2018, Finite Element Method for Solids and Structures.

[7]  W. Swinbank Long‐wave radiation from clear skies , 1963 .

[8]  P. A. Sheppard,et al.  Long-wave radiation from clear skies , 1964 .

[9]  P. D. Metz,et al.  A Simple Computer Program to Model Three-Dimensional Underground Heat Flow With Realistic Boundary Conditions , 1983 .

[10]  Athanassios A. Argiriou,et al.  Analysis of the accuracy and sensitivity of eight models to predict the performance of earth-to-air heat exchangers , 1992 .

[11]  S. Kavanaugh,et al.  Ground source heat pumps , 1998 .

[12]  Eli Korin,et al.  Thermal analysis of a helical heat exchanger for ground thermal energy storage in arid zones , 1996 .

[13]  J. V. C. Vargas,et al.  A Numerical Model to Predict the Thermal and Psychrometric Response of Electronic Packages , 2001 .

[14]  Shu-Kun Lin,et al.  Shape and Structure, from Engineering to Nature , 2001, Entropy.