Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study.

BACKGROUND With regard to implant-supported prostheses, to date no technique has been proven to guarantee a completely passive fit of prosthetic frameworks. Several clinical variables may affect the precision of impressions, particularly in the presence of implants. PURPOSE To compare the accuracy of implant impressions made with different materials, lengths of impression coping connections, and not parallel position of the implants. MATERIALS AND METHODS A calibrated testing device allowing reproducible standardized positions was used. Two control groups of master models and eight experimental groups with predetermined undercuts were used to make addition silicon and polyether implant impressions by means of the open-tray pick-up technique. Four reference distances were evaluated on each study cast by using a profile projector and a standardized measurement protocol. The data were statistically analyzed by means of three-factor analysis of variance. RESULTS The impressions made in the presence of angulated implants were significantly less accurate than the ones made with parallel implants. The tested addition silicon resulted advantageous in presence of nonparallel implants whereas the polyether achieved the best results with parallel implants and standard impression copings. CONCLUSIONS The angulation of the implants may cause strains of impressions, probably because of the higher forces required for the impression removal. Moreover, undercuts negatively affected the impression accuracy. More accurate casts were obtained using the tested addition silicon in the presence of nonparallel implants and using a standard length connection of the copings in the presence of parallel implants, respectively.

[1]  M F Daoudi,et al.  A laboratory investigation of the accuracy of two impression techniques for single-tooth implants. , 2001, The International journal of prosthodontics.

[2]  A B Carr,et al.  Comparison of impression techniques for a five-implant mandibular model. , 1992, The International journal of oral & maxillofacial implants.

[3]  Chong-Hyun Han,et al.  Displacement of implant components from impressions to definitive casts. , 2006, The International journal of oral & maxillofacial implants.

[4]  B R Lang,et al.  Clinical methods for evaluating implant framework fit. , 1999, The Journal of prosthetic dentistry.

[5]  M G Barrett,et al.  The accuracy of six impression techniques for osseointegrated implants. , 1993, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[6]  Elman C Jameson,et al.  Electrical Discharge Machining , 2001 .

[7]  P Yaman,et al.  The accuracy of implant master casts constructed from transfer impressions. , 1990, The International journal of oral & maxillofacial implants.

[8]  S A Aquilino,et al.  Evaluation of three impression techniques for osseointegrated oral implants. , 1993, The Journal of prosthetic dentistry.

[9]  S A Aquilino,et al.  Strategies to achieve fit in implant prosthodontics: a review of the literature. , 1999, The International journal of prosthodontics.

[10]  D Assif,et al.  Comparative accuracy of implant impression procedures. , 1992, The International journal of periodontics & restorative dentistry.

[11]  Sergio Adán-Plaza,et al.  Temperature effects on the rheological properties of current polyether and polysiloxane impression materials during setting. , 2003, The Journal of prosthetic dentistry.

[12]  P J Becker,et al.  Evaluation of impression accuracy for osseointegrated implant supported superstructures. , 2000, The Journal of prosthetic dentistry.

[13]  C Bessing,et al.  Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. , 1994, The International journal of oral & maxillofacial implants.

[14]  B R Lang,et al.  Measuring fit at the implant prosthodontic interface. , 1996, The Journal of prosthetic dentistry.

[15]  W. Eames,et al.  Elastomeric impression materials: effect of bulk on accuracy. , 1979, The Journal of prosthetic dentistry.

[16]  B R Lang,et al.  Fit of implant frameworks fabricated by different techniques. , 1997, The Journal of prosthetic dentistry.

[17]  P. Vigolo,et al.  Evaluation of the accuracy of three techniques used for multiple implant abutment impressions. , 2003, The Journal of prosthetic dentistry.

[18]  J I Nicholls,et al.  The measurement of distortion: mathematical considerations. , 1978, The Journal of prosthetic dentistry.

[19]  U. Lekholm,et al.  Bone response to implant-supported frameworks with differing degrees of misfit preload: in vivo study in rabbits. , 2000, Clinical implant dentistry and related research.

[20]  P Millstein,et al.  Determining the accuracy of stock and custom tray impression/casts. , 1998, Journal of oral rehabilitation.

[21]  J I Nicholls The measurement of distortion: theoretical considerations. , 1977, The Journal of prosthetic dentistry.

[22]  D L Dixon,et al.  Custom impression trays. Part II: Removal forces. , 1994, The Journal of prosthetic dentistry.

[23]  J I Nicholls,et al.  Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. , 1993, The International journal of prosthodontics.

[24]  Luis C F Frasca,et al.  Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments. , 2004, The International journal of oral & maxillofacial implants.

[25]  Bjarni E Pjetursson,et al.  A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years , 2008, BDJ.

[26]  W R Laney,et al.  Tissue-integrated prosthesis complications. , 1993, The International journal of oral & maxillofacial implants.

[27]  H. G. Filho,et al.  Evaluation of Transfer Impressions for Osseointegrated Implants at Various Angulations , 2004, Implant dentistry.

[28]  Heather J. Conrad,et al.  Accuracy of two impression techniques with angulated implants. , 2007, The Journal of prosthetic dentistry.

[29]  Leslie Howe,et al.  Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. , 2003, The Journal of prosthetic dentistry.

[30]  K. W. LaBarge Electrical discharge machining. , 1997, Journal of dental technology : the peer-reviewed publication of the National Association of Dental Laboratories.

[31]  J Robert Kelly,et al.  Developing meaningful systematic review of CAD/CAM reconstructions and fiber-reinforced composites. , 2007, Clinical oral implants research.

[32]  T. Jemt,et al.  Fixed implant-supported prostheses with welded titanium frameworks. , 1992, The International journal of periodontics & restorative dentistry.

[33]  R L Schneider,et al.  Fabricating low-fusing metal casts for more accurate implant prosthodontics. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[34]  P L Millstein,et al.  A comparative analysis of the accuracy of implant transfer techniques. , 1993, The Journal of prosthetic dentistry.

[35]  D. Setchell,et al.  A laboratory investigation of the accuracy of the repositioning impression coping technique at the implant level for single-tooth implants. , 2003, The European journal of prosthodontics and restorative dentistry.

[36]  K. Akca,et al.  Accuracy of 2 impression techniques for ITI implants. , 2004, The International journal of oral & maxillofacial implants.

[37]  T Jemt,et al.  In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. , 1996, The International journal of oral & maxillofacial implants.

[38]  T Jemt,et al.  Failures and complications in 127 consecutively placed fixed partial prostheses supported by Brånemark implants: from prosthetic treatment to first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[39]  C J Goodacre,et al.  The effect of using custom or stock trays on the accuracy of gypsum casts. , 1996, The International journal of prosthodontics.

[40]  Alvin G. Wee Comparison of impression materials for direct multi-implant impressions. , 2000, The Journal of prosthetic dentistry.

[41]  J. Lindhe,et al.  Different types of inflammatory reactions in peri-implant soft tissues. , 2005, Journal of clinical periodontology.

[42]  Andrea Borracchini,et al.  Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. , 2008, The journal of contemporary dental practice.

[43]  P. Vigolo,et al.  Master cast accuracy in single-tooth implant replacement cases: an in vitro comparison. A technical note. , 2005, The International journal of oral & maxillofacial implants.

[44]  P. Vigolo,et al.  An evaluation of impression techniques for multiple internal connection implant prostheses. , 2004, The Journal of prosthetic dentistry.

[45]  D. Kohavi Complications in the tissue integrated prostheses components: clinical and mechanical evaluation. , 1993, Journal of oral rehabilitation.

[46]  J. Hobkirk,et al.  An in vivo investigation of seating and removal forces associated with recording impressions in dentate patients. , 1995, The Journal of prosthetic dentistry.

[47]  J. Powers,et al.  Mechanical properties of 3 hydrophilic addition silicone and polyether elastomeric impression materials. , 2004, The Journal of prosthetic dentistry.

[48]  Davis Rd,et al.  Dual-arch and custom tray impression accuracy. , 1991 .

[49]  J L Nicholls The measurement of distortion: concluding remarks. , 1980, The Journal of prosthetic dentistry.

[50]  Changyong Feng,et al.  Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. , 2008, The Journal of prosthetic dentistry.

[51]  Schmitt Sm,et al.  Fabrication of titanium implant-retained restorations with nontraditional machining techniques. , 1995 .

[52]  G. H. Johnson,et al.  The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions. , 2003, The Journal of prosthetic dentistry.

[53]  P. Vigolo,et al.  In vitro comparison of master cast accuracy for single-tooth implant replacement. , 2000, The Journal of prosthetic dentistry.

[54]  J I Nicholls,et al.  Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. , 1993, The International journal of prosthodontics.

[55]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.

[56]  K. Akca,et al.  Impression techniques and misfit-induced strains on implant-supported superstructures: an in vitro study. , 2006, The international journal of periodontics & restorative dentistry.

[57]  J I Nicholls,et al.  An evaluation of impression techniques for osseointegrated implants. , 1990, The Journal of prosthetic dentistry.

[58]  D Assif,et al.  Accuracy of implant impression techniques. , 1996, The International journal of oral & maxillofacial implants.

[59]  Torsten Jemt,et al.  Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible. , 2003, The International journal of prosthodontics.

[60]  I. Pesun Intrusion of teeth in the combination implant-to-natural-tooth fixed partial denture: a review of the theories. , 1997, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[61]  A B Carr,et al.  The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[62]  G. Dahlén,et al.  Microbial findings at failing implants. , 1999, Clinical oral implants research.

[63]  T. Taylor,et al.  Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures. , 2004, Clinical oral implants research.

[64]  M. Çehreli,et al.  The Significance Of Passive Framework Fit In Implant Prosthodontics: Current Status , 2001, Implant dentistry.

[65]  D Assif,et al.  Accuracy of implant impression splinted techniques: effect of splinting material. , 1999, The International journal of oral & maxillofacial implants.