Bi-Fi: An Embedded Sensor/System Architecture for Remote Biological Monitoring

Wireless-enabled processor modules intended for communicating low-frequency phenomena (i.e., temperature, humidity, and ambient light) have been enabled to acquire and transmit multiple biological signals in real time, which has been achieved by using computationally efficient data acquisition, filtering, and compression algorithms, and interfacing the modules with biological interface hardware. The sensor modules can acquire and transmit raw biological signals at a rate of 32 kb/s, which is near the hardware limit of the modules. Furthermore, onboard signal processing enables one channel, sampled at a rate of 4000 samples/s at 12-bit resolution, to be compressed via adaptive differential-pulse-code modulation (ADPCM) and transmitted in real time. In addition, the sensors can be configured to filter and transmit individual time-referenced ldquospikerdquo waveforms, or to transmit the spike height and width for alleviating network traffic and increasing battery life. The system is capable of acquiring eight channels of analog signals as well as data via an asynchronous serial connection. A back-end server archives the biological data received via networked gateway sensors, and hosts them to a client application that enables users to browse recorded data. The system also acquires, filters, and transmits oxygen saturation and pulse rate via a commercial-off-the-shelf interface board. The system architecture can be configured for performing real-time nonobtrusive biological monitoring of humans or rodents. This paper demonstrates that low-power, computational, and bandwidth-constrained wireless-enabled platforms can indeed be leveraged for wireless biosignal monitoring.

[1]  M. Modarreszadeh,et al.  Wireless, 32-channel, EEG and epilepsy monitoring system , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[2]  M S Lewicki,et al.  A review of methods for spike sorting: the detection and classification of neural action potentials. , 1998, Network.

[3]  Daryl R. Kipke,et al.  Wireless implantable microsystems: high-density electronic interfaces to the nervous system , 2004, Proceedings of the IEEE.

[4]  P. Mohseni,et al.  Wireless multichannel biopotential recording using an integrated FM telemetry circuit , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  L. Leija,et al.  ASIC-based batteryless implantable telemetry microsystem for recording purposes , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[6]  S. Farshchi,et al.  A TinyOS-Based Wireless Neural Sensing, Archiving, and Hosting System , 2005, Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005..

[7]  Andreas Nieder,et al.  Miniature stereo radio transmitter for simultaneous recording of multiple single-neuron signals from behaving owls , 2000, Journal of Neuroscience Methods.

[8]  S. Farshchi,et al.  Acquiring High-Rate Neural Spike Data with Hardware-Constrained Embedded Sensors , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  Mohd Fadlee A. Rasid,et al.  Bluetooth telemedicine Processor for multichannel biomedical signal transmission via mobile cellular networks , 2005, IEEE Transactions on Information Technology in Biomedicine.

[10]  Deborah Estrin,et al.  A system for simulation, emulation, and deployment of heterogeneous sensor networks , 2004, SenSys '04.

[11]  Jianchu Yao,et al.  A wearable point-of-care system for home use that incorporates plug-and-play and wireless standards , 2005, IEEE Transactions on Information Technology in Biomedicine.

[12]  Patrick D Wolf,et al.  A multichannel telemetry system for single unit neural recordings , 2004, Journal of Neuroscience Methods.

[13]  R.R. Harrison,et al.  Validation of adaptive threshold spike detector for neural recording , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  Hongjiang Song,et al.  Single chip system for bio-data acquisition, digitization and telemetry , 1997, Proceedings of 1997 IEEE International Symposium on Circuits and Systems. Circuits and Systems in the Information Age ISCAS '97.

[15]  Miguel A. L. Nicolelis,et al.  Methods for Neural Ensemble Recordings , 1998 .

[16]  Deborah Estrin,et al.  Capturing high-frequency phenomena using a bandwidth-limited sensor network , 2006, SenSys '06.

[17]  P. Irazoqui-Pastor,et al.  Transcutaneous RF-powered neural recording device , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[18]  C. Subbe,et al.  Validation of a modified Early Warning Score in medical admissions. , 2001, QJM : monthly journal of the Association of Physicians.

[19]  Reid R. Harrison,et al.  A low-power integrated circuit for adaptive detection of action potentials in noisy signals , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[20]  Matt Welsh,et al.  Sensor networks for emergency response: challenges and opportunities , 2004, IEEE Pervasive Computing.

[21]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[22]  Majid Sarrafzadeh,et al.  Adaptive medical feature extraction for resource constrained distributed embedded systems , 2006, Fourth Annual IEEE International Conference on Pervasive Computing and Communications Workshops (PERCOMW'06).

[23]  W J Tompkins,et al.  Applications of artificial neural networks for ECG signal detection and classification. , 1993, Journal of electrocardiology.

[24]  Gregory T. A. Kovacs,et al.  A multiparameter wearable physiologic monitoring system for space and terrestrial applications , 2005, IEEE Transactions on Information Technology in Biomedicine.

[25]  I. Shimoyama,et al.  A three-dimensional shape memory alloy microelectrode with clipping structure for insect neural recording , 2000, Journal of Microelectromechanical Systems.

[26]  Gu-Yeon Wei,et al.  A portable, low-power, wireless two-lead EKG system , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[27]  Aleksey Pesterev,et al.  A TinyOS-enabled MICA2-BasedWireless neural interface , 2006, IEEE Transactions on Biomedical Engineering.

[28]  Robert Szewczyk,et al.  System architecture directions for networked sensors , 2000, ASPLOS IX.

[29]  R.R. Harrison,et al.  A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System , 2006, IEEE Journal of Solid-State Circuits.

[30]  Patrick D. Wolf,et al.  Evaluation of spike-detection algorithms fora brain-machine interface application , 2004, IEEE Transactions on Biomedical Engineering.

[31]  James L. Flanagan,et al.  Adaptive quantization in differential PCM coding of speech , 1973 .

[32]  G. Buzsáki,et al.  Pattern and inhibition-dependent invasion of pyramidal cell dendrites by fast spikes in the hippocampus in vivo. , 1996, Proceedings of the National Academy of Sciences of the United States of America.