Real-Time Compton Imaging for the GammaTracker Handheld CdZnTe Detector

We are currently developing a handheld radioisotope identifier containing 18 position-sensitive CdZnTe crystals. In addition to isotope identification, the device performs basic Compton imaging to determine the location of suspected sources. This paper presents two computationally efficient algorithms for this purpose. The first algorithm traces individual Compton cones onto the unit sphere, whereas the second algorithm computes the intersection of two Compton cones and the unit sphere. Simulations demonstrate that the algorithms are suitable for determining the directionality, even with features such as uncertainty calculations omitted. The one-cone algorithm works more efficiently at high count rates, but the two-cone algorithm generates fewer image artifacts.

[1]  B. Phlips,et al.  Three-Compton telescope: theory, simulations, and performance , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[2]  E. Aprile,et al.  Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT) , 2000, SPIE Optics + Photonics.

[3]  J.E. Berry,et al.  Improved resolution for 3-D position sensitive CdZnTe spectrometers , 2003, IEEE Transactions on Nuclear Science.

[4]  S. E. Boggs,et al.  Event reconstruction in high resolution Compton telescopes , 2000 .

[5]  K. Vetter,et al.  Gamma-ray imaging with position-sensitive HPGe detectors , 2004 .

[6]  Michael R. Squillante,et al.  Advanced multi-dimensional imaging of gamma-ray radiation , 2003 .

[7]  M. Cherry,et al.  A Directional Algorithm for an Electronically-collimated Gamma-ray Detector , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[8]  R. Forster,et al.  MCNP™ Version 5 , 2004 .

[9]  Zhong He,et al.  4/spl pi/ Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[10]  N. Gehrels,et al.  Performance of a Compton telescope using position-sensitive germanium detectors , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[11]  Wei Chang,et al.  Angular uncertainties due to geometry and spatial resolution in Compton cameras , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[12]  V. Schönfelder,et al.  A telescope for soft gamma ray astronomy , 1973 .

[13]  A. Zoglauer First light for the next generation of compton and pair telescopes : development of new techniques for the data analysis of combined compton and pair telescopes and their application to the MEGA prototype , 2005 .

[14]  W. L. Rogers,et al.  Fast algorithm for list mode back-projection of Compton scatter camera data , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[15]  Bo Cederwall,et al.  Backtracking as a way to reconstruct Compton scattered γ-rays , 1999 .