SeisMote: A Multi-Sensor Wireless Platform for Cardiovascular Monitoring in Laboratory, Daily Life, and Telemedicine

This article presents a new wearable platform, SeisMote, for the monitoring of cardiovascular function in controlled conditions and daily life. It consists of a wireless network of sensorized nodes providing simultaneous multiple measures of electrocardiogram (ECG), acceleration, rotational velocity, and photoplethysmogram (PPG) from different body areas. A custom low-power transmission protocol was developed to allow the concomitant real-time monitoring of 32 signals (16 bit @200 Hz) from up to 12 nodes with a jitter in the among-node time synchronization lower than 0.2 ms. The BluetoothLE protocol may be used when only a single node is needed. Data can also be collected in the off-line mode. Seismocardiogram and pulse transit times can be derived from the collected data to obtain additional information on cardiac mechanics and vascular characteristics. The employment of the system in the field showed recordings without data gaps caused by transmission errors, and the duration of each battery charge exceeded 16 h. The system is currently used to investigate strategies of hemodynamic regulation in different vascular districts (through a multisite assessment of ECG and PPG) and to study the propagation of precordial vibrations along the thorax. The single-node version is presently exploited to monitor cardiac patients during telerehabilitation.

[1]  Tapas Mondal,et al.  Wearable Sensors for Remote Health Monitoring , 2017, Sensors.

[2]  Eero Lehtonen,et al.  Automated Detection of Atrial Fibrillation Based on Time–Frequency Analysis of Seismocardiograms , 2017, IEEE Journal of Biomedical and Health Informatics.

[3]  Amirtaha Taebi,et al.  Recent Advances in Seismocardiography , 2019, Vibration.

[4]  Kouhyar Tavakolian,et al.  Precordial Vibrations Provide Noninvasive Detection of Early-Stage Hemorrhage , 2014, Shock.

[5]  J. F. Norris,et al.  Real-time compression of myoelectric data utilising adaptive differential pulse code modulation , 1995, Medical and Biological Engineering and Computing.

[6]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[7]  Alexander Samol,et al.  Recording of Bipolar Multichannel ECGs by a Smartwatch: Modern ECG Diagnostic 100 Years after Einthoven , 2019, Sensors.

[8]  A. Ephremides,et al.  A design concept for reliable mobile radio networks with frequency hopping signaling , 1987, Proceedings of the IEEE.

[9]  A. O. Bicen,et al.  Novel Wearable Seismocardiography and Machine Learning Algorithms Can Assess Clinical Status of Heart Failure Patients , 2018, Circulation. Heart failure.

[10]  Peter J. Hannan,et al.  Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle , 1994 .

[11]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[12]  J. Carroll,et al.  Determination of pulse wave velocities with computerized algorithms. , 1991, American heart journal.

[13]  Mikko Paukkunen,et al.  Beat-by-Beat Quantification of Cardiac Cycle Events Detected From Three-Dimensional Precordial Acceleration Signals , 2016, IEEE Journal of Biomedical and Health Informatics.

[14]  Kouhyar Tavakolian,et al.  Ballistocardiography and Seismocardiography: A Review of Recent Advances , 2015, IEEE Journal of Biomedical and Health Informatics.

[15]  Izhak Rubin,et al.  Access-control disciplines for multi-access communication channels: Reservation and TDMA schemes , 1979, IEEE Trans. Inf. Theory.

[16]  Aleksey Pesterev,et al.  Bi-Fi: An Embedded Sensor/System Architecture for Remote Biological Monitoring , 2007, IEEE Transactions on Information Technology in Biomedicine.

[17]  N. Kuster,et al.  Energy absorption mechanism by biological bodies in the near field of dipole antennas above 300 MHz , 1992 .

[18]  E. Y. K. Ng,et al.  SVR ensemble-based continuous blood pressure prediction using multi-channel photoplethysmogram , 2019, Comput. Biol. Medicine.

[19]  Md. Saiful Islam,et al.  A comprehensive review of wireless body area network , 2019, J. Netw. Comput. Appl..

[20]  K. Radermacher,et al.  Simplified detection of myocardial ischemia by seismocardiography , 2013, Herz.

[21]  Kasper Sørensen,et al.  Definition of Fiducial Points in the Normal Seismocardiogram , 2018, Scientific Reports.

[22]  J. Elson,et al.  Fine-grained network time synchronization using reference broadcasts , 2002, OSDI '02.

[23]  Harold L. Kennedy The History, Science, and Innovation of Holter Technology , 2006, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc.

[24]  Yeqiong Song,et al.  Real-time communications using TDMA-based multi-access protocol , 1997, Comput. Commun..

[25]  Junaidah Bte Mustafa Kamal.,et al.  Remote health monitoring. , 2013 .

[26]  Rahat Ali Khan,et al.  The state-of-the-art wireless body area sensor networks: A survey , 2018, Int. J. Distributed Sens. Networks.

[27]  Theodore S. Rappaport,et al.  Wireless communications - principles and practice , 1996 .

[28]  James L. Flanagan,et al.  Adaptive quantization in differential PCM coding of speech , 1973 .

[29]  F. Rizzo,et al.  Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects , 2013, Autonomic Neuroscience.

[30]  Ramjee Prasad,et al.  Strategies for adaptive frequency hopping in the unlicensed bands , 2006, IEEE Wireless Communications.