The 5200 cycle test of an 8-cm diameter Hg ion thruster

An accelerated cycle test was conducted in which an 8-cm Engineering Model Thruster (EMT) prototype successfully completed 5200 on-off cycles and a total of more than 1300hours of thruster operation at a 4.5 mN thrust level. Cathode tip heater powers required for starting and keeper voltages remained well within acceptable limits. The discharge chamber utilization and electrical efficiency were nearly constant over the duration of the test. It was concluded that on-off cyclic operation by itself does not appreciably degrade starting capability or performance of the 8-cm EMT.