Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information – potential application for MR-only radiotherapy and attenuation correction in positron emission tomography

Abstract Background. Estimation of computed tomography (CT) equivalent data, i.e. a substitute CT (s-CT), from magnetic resonance (MR) images is a prerequisite both for attenuation correction of positron emission tomography (PET) data acquired with a PET/MR scanner and for dose calculations in an MR-only radiotherapy workflow. It has previously been shown that it is possible to estimate Hounsfield numbers based on MR image intensities, using ultra short echo-time imaging and Gaussian mixture regression (GMR). In the present pilot study we investigate the possibility to also include spatial information in the GMR, with the aim to improve the quality of the s-CT. Material and methods. MR and CT data for nine patients were used in the present study. For each patient, GMR models were created from the other eight patients, including either both UTE image intensities and spatial information on a voxel by voxel level, or only UTE image intensities. The models were used to create s-CT images for each respective patient. Results. The inclusion of spatial information in the GMR model improved the accuracy of the estimated s-CT. The improvement was most pronounced in smaller, complicated anatomical regions as the inner ear and post-nasal cavities. Conclusions. This pilot study shows that inclusion of spatial information in GMR models to convert MR data to CT equivalent images is feasible. The accuracy of the s-CT is improved and the spatial information could make it possible to create a general model for the conversion applicable to the whole body.

[1]  B. Zackrisson,et al.  Dedicated magnetic resonance imaging in the radiotherapy clinic. , 2009, International journal of radiation oncology, biology, physics.

[2]  Gudrun Wagenknecht,et al.  Knowledge-based segmentation of attenuation-relevant regions of the head in T1-weighted MR images for attenuation correction in MR/PET systems , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[3]  Ciprian Catana,et al.  Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype , 2010, The Journal of Nuclear Medicine.

[4]  Tufve Nyholm,et al.  Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions , 2010, Radiation oncology.

[5]  S. Vandenberghe,et al.  MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences , 2010, Journal of Nuclear Medicine.

[6]  Hans Herzog,et al.  Template based attenuation correction for PET in MR-PET scanners , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[7]  Adam Johansson,et al.  CT substitute derived from MRI sequences with ultrashort echo time. , 2011, Medical physics.

[8]  Adam Johansson,et al.  Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images , 2013, Magnetic Resonance Materials in Physics, Biology and Medicine.

[9]  H. Herzog,et al.  Attenuation correction in MR-PET scanners with segmented T1-weighted MR images , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[10]  Bernhard Schölkopf,et al.  MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration , 2008, Journal of Nuclear Medicine.

[11]  Mika Kapanen,et al.  T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning , 2013, Acta oncologica.

[12]  Christopher M. Rank,et al.  MRI-based treatment plan simulation and adaptation for ion radiotherapy using a classification-based approach , 2013, Radiation Oncology.

[13]  C. Kuhl,et al.  MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence , 2012, The Journal of Nuclear Medicine.

[14]  H. Zaidi,et al.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography. , 2003, Medical physics.

[15]  B. Schölkopf,et al.  MR-Based PET attenuation correction for PET/MR imaging. , 2013, Seminars in nuclear medicine.

[16]  Jun Yu,et al.  Voxel-wise uncertainty in CT substitute derived from MRI. , 2012, Medical physics.

[17]  Olivier Salvado,et al.  An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. , 2012, International journal of radiation oncology, biology, physics.