Online Measurement Of The Working Fluid Mass Repartition In A Small-Scale Organic Rankine Cycle Power System

This paper presents an experimental investigation of the working fluid charge repartition in a 2kWe ORC (organic Rankine cycle) test bench. To this end, an online measurement apparatus is built and fully calibrated to evaluate the charge enclosed in the three heat exchangers and the liquid receiver of the ORC unit. By changing all the system boundary conditions (including the charge enclosed in the test rig), an experimental database of 304 steady-state points is gathered and post-treated. The charge inventories obtained by online measurements demonstrate promising results on average but experience high uncertainties when considering each point individually (i.e. the uncertainty on the global inventory is around ± 2.5 kg for a total charge of 31.2 kg). Deviations of the evaporator mass measurements are identified at high temperature of the heat source and discussed in details. A reconciliation method is applied to the raw measurements in order to retrieve consistent charge inventories while accounting for the different sources of uncertainty. Ultimately, the paper analyses the impact of increasing the charge in the ORC and how this parameter influences the thermodynamic state of the system.

[1]  Tong Zhu,et al.  Simulation of working fluid mass distribution in small-scale Organic Rankine Cycle system under sub-critical conditions , 2018 .

[2]  Vincent Lemort,et al.  Charge-sensitive modelling of organic Rankine cycle power systems for off-design performance simulation , 2018 .

[3]  Tong Zhu,et al.  Working fluid charge oriented off-design modeling of a small scale Organic Rankine Cycle system , 2017 .

[4]  S. Quoilin,et al.  Effects of void fraction and heat transfer correlations in a charge-sensitive ORC model – a comparison with experimental data , 2017 .

[5]  Vincent Lemort,et al.  Modelling of organic Rankine cycle power systems in off-design conditions: An experimentally-validated comparative study , 2017 .

[6]  P. Hrnjak,et al.  Refrigerant and lubricant charge in air condition heat exchangers: Experimentally validated model , 2016 .

[7]  James E. Braun,et al.  Development and a Validation of a Charge Sensitive Organic Rankine Cycle (ORC) Simulation Tool , 2016 .

[8]  Jian Lu,et al.  Measurement of refrigerant mass distribution within a R290 split air conditioner , 2015 .

[9]  Vincent Lemort,et al.  Importance of the reconciliation method to handle experimental data: application to a reversible heat pump / organic Rankine cycle unit integrated in a positive energy building , 2015 .

[10]  Vincent Lemort,et al.  Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp , 2014, Industrial & engineering chemistry research.

[11]  P. Zhang,et al.  Practical methods for measuring refrigerant mass distribution inside refrigeration system , 2009 .

[12]  Erik T. Björk A simple technique for refrigerant mass measurement , 2005 .

[13]  Steffen Peuker,et al.  Experimental and analytical investigation of refrigerant and lubricant migration , 2010 .

[14]  S. Quoilin,et al.  Purdue E-pubs Experimental Investigation of an Orc System for a Micro-solar Power Plant Experimental Investigation of an Orc System for a Micro-solar Power Plant , 2022 .