A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae.

BACKGROUND Flapless implant placement using guided surgery is widespread, although clinical publications on the precision are lacking. PURPOSE The purpose of this study was to evaluate the accuracy of mucosal-supported stereolithographic guides in the edentulous maxillae. MATERIALS AND METHODS Seventy-eight OsseoSpeed™ implants (Astra Tech AB, Mölndal, Sweden) of 3.5 to 5 mm width and 8 to 15 mm length were installed consecutively in 13 patients. Implants were functionally loaded on the day of surgery, and implant location was assessed with a computed tomography scan. Mimics 9.0 software (Materialise N.V., Leuven, Belgium) was used to fuse the images of the virtually planned and actually placed implants, and the locations, axes, and interimplant distances were compared. RESULTS One implant was lost shortly after insertion because of abscess formation caused by remnants of impression material. Seventy-seven implant locations were analyzed. The deviation at the entrance point ranged between 0.29 mm and 2.45 mm (SD: 0.44 mm), with a mean of 0.91 mm. Average angle deviation was 2.60° (range 0.16-8.86°; SD: 1.61°). At the apical point, the deviation ranged between 0.32 mm and 3.01 mm, with a mean of 1.13 mm (SD: 0.52 mm). The mean deviation of the coronal and apical interimplant distance was respectively 0.18 mm (range 0.07-0.32 mm; SD: 0.15) and 0.33 mm (range 0.12-0.69 mm; SD: 0.28). These deviations are lower than the global coronal and apical deviations. CONCLUSION The present study is the first to investigate the accuracy of stereolithographic, full, mucosally supported surgical guides in the treatment of fully edentulous maxillae. Clinicians should be warned that angular and linear deviations are to be expected. Short implants show significantly lower apical deviations compared with longer ones. Reasons for implant deviations are multifactorial; however, it is unlikely that the production process of the guide has a major impact on the total accuracy of a mucosal-supported stereolithographic guide.

[1]  M S Schwarz,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery. Work in progress. , 1988, Radiology.

[2]  Tomas Albrektsson,et al.  Osseointegrated Oral implants , 1988 .

[3]  R Jacobs,et al.  Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. , 2007, Journal of clinical periodontology.

[4]  Guy Marchal,et al.  An image-guided planning system for endosseous oral implants , 1998, IEEE Transactions on Medical Imaging.

[5]  Patricia R Cury,et al.  Clinical application of stereolithographic surgical guides for implant placement: preliminary results. , 2005, Journal of periodontology.

[6]  Reinhilde Jacobs,et al.  Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. , 2003, Clinical oral implants research.

[7]  Basten Ch,et al.  The use of radiopaque templates for predictable implant placement. , 1995 .

[8]  C H Basten,et al.  The use of radiopaque templates for predictable implant placement. , 1995, Quintessence international.

[9]  J L Coudert,et al.  Precise dental implant placement in bone using surgical guides in conjunction with medical imaging techniques. , 2000, The Journal of oral implantology.

[10]  Daniel van Steenberghe,et al.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. , 2007, The Journal of prosthetic dentistry.

[11]  R Jacobs,et al.  Predictability of a three-dimensional planning system for oral implant surgery. , 1999, Dento maxillo facial radiology.

[12]  T. van de Velde,et al.  A model study on flapless implant placement by clinicians with a different experience level in implant surgery. , 2007, Clinical oral implants research.

[13]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.

[14]  C Politis,et al.  Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. , 2003, International journal of oral and maxillofacial surgery.

[15]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[16]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[17]  H. De Bruyn,et al.  Early loading of machined-surface Brånemark implants in completely edentulous mandibles: healed bone versus fresh extraction sites. , 2002, Clinical implant dentistry and related research.

[18]  D. Bandy,et al.  CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery , 1989 .

[19]  R Jacobs,et al.  Predictability of reformatted computed tomography for pre-operative planning of endosseous implants. , 1999, Dento maxillo facial radiology.

[20]  Guillaume Champleboux,et al.  Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. , 2002, Clinical oral implants research.

[21]  Predrag Sukovic,et al.  Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.

[22]  K H Thunthy,et al.  Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement. , 1998, Practical periodontics and aesthetic dentistry : PPAD.

[23]  H Israelson,et al.  Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. , 1992, The International journal of periodontics & restorative dentistry.

[24]  David P Sarment,et al.  Stereolithographic surgical templates for placement of dental implants in complex cases. , 2003, The International journal of periodontics & restorative dentistry.

[25]  N Freiberg,et al.  Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. , 1988, Journal of periodontology.

[26]  Scott D. Ganz Computer-Guided Surgery Utilizing a Computer-Milled Surgical Template , 2001 .