A study of hyperelastic models for predicting the mechanical behavior of extensor apparatus

In this research, the nonlinear elastic behavior of human extensor apparatus was investigated. To this goal, firstly the best material parameters of hyperelastic strain energy density functions consisting of the Mooney–Rivlin, Ogden, invariants, and general exponential models were derived for the simple tension experimental data. Due to the significance of stress response in other deformation modes of nonlinear models, the calculated parameters were used to study the pure shear and balance biaxial tension behavior of the extensor apparatus. The results indicated that the Mooney–Rivlin model predicts an unstable behavior in the balance biaxial deformation of the extensor apparatus, while the Ogden order 1 represents a stable behavior, although the fitting of experimental data and theoretical model was not satisfactory. However, the Ogden order 6 model was unstable in the simple tension mode and the Ogden order 5 and general exponential models presented accurate and stable results. In order to reduce the material parameters, the invariants model with four material parameters was investigated and this model presented the minimum error and stable behavior in all deformation modes. The ABAQUS Explicit solver was coupled with the VUMAT subroutine code of the invariants model to simulate the mechanical behavior of the central and terminal slips of the extensor apparatus during the passive finger flexion, which is important in the prediction of boutonniere deformity and chronic mallet finger injuries, respectively. Also, to evaluate the adequacy of constitutive models in simulations, the results of the Ogden order 5 were presented. The difference between the predictions was attributed to the better fittings of the invariants model compared with the Ogden model.

[1]  Sang Wook Lee,et al.  Mechanical properties vary for different regions of the finger extensor apparatus. , 2014, Journal of biomechanics.

[2]  K. Schindhelm,et al.  Elastic and viscoelastic properties of porcine subdermal fat using MRI and inverse FEA , 2010, Biomechanics and modeling in mechanobiology.

[3]  D. W. Saunders,et al.  Large elastic deformations of isotropic materials VII. Experiments on the deformation of rubber , 1951, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.

[4]  P. Bellemère Treatment of chronic extensor tendons lesions of the fingers. , 2015, Chirurgie de la main.

[5]  Michael Vande Weghe,et al.  An extensor mechanism for an anatomical robotic hand , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[6]  M. Kargarnovin,et al.  Hyperelastic materials modelling using a strain measure consistent with the strain energy postulates , 2010 .

[7]  R. Smith,et al.  Balance and kinetics of the fingers under normal and pathological conditions. , 1974, Clinical orthopaedics and related research.

[8]  K. Narooei,et al.  Investigation of hyperelastic models for nonlinear elastic behavior of demineralized and deproteinized bovine cortical femur bone. , 2016, Journal of the mechanical behavior of biomedical materials.

[9]  Rami Haj-Ali,et al.  Hyperelastic mechanical behavior of chitosan hydrogels for nucleus pulposus replacement-experimental testing and constitutive modeling. , 2012, Journal of the mechanical behavior of biomedical materials.

[10]  K. An,et al.  Extensor mechanism of the fingers. II. Tensile properties of components. , 1991, The Journal of hand surgery.

[11]  Alojz Ivankovic,et al.  Mechanical characterisation of polyurethane elastomer for biomedical applications. , 2010, Journal of the mechanical behavior of biomedical materials.

[12]  T. Brown,et al.  Apparent transverse compressive material properties of the digital flexor tendons and the median nerve in the carpal tunnel. , 2011, Journal of biomechanics.

[13]  M. N. Bajuri,et al.  A hyperelastic fibre-reinforced continuum model of healing tendons with distributed collagen fibre orientations , 2016, Biomechanics and modeling in mechanobiology.

[14]  Sang Wook Lee,et al.  Effect of finger posture on the tendon force distribution within the finger extensor mechanism. , 2008, Journal of biomechanical engineering.

[15]  H. Darijani,et al.  Constitutive modeling of isotropic hyperelastic materials in an exponential framework using a self-contained approach , 2014 .

[17]  Barbara Wirthl,et al.  Modelling of Brain Deformation After Decompressive Craniectomy , 2016, Annals of Biomedical Engineering.

[18]  T. Beda,et al.  An approach for hyperelastic model-building and parameters estimation a review of constitutive models , 2014 .

[19]  Luc Soler,et al.  Experimental mechanical characterization of abdominal organs: liver, kidney & spleen. , 2013, Journal of the mechanical behavior of biomedical materials.

[20]  Tammy L Haut Donahue,et al.  Hyperelastic properties of human meniscal attachments. , 2011, Journal of biomechanics.

[21]  Benjamin J. Ellis,et al.  Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies , 2013, Biomechanics and Modeling in Mechanobiology.

[22]  Gerhard A. Holzapfel,et al.  Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science , 2000 .

[23]  Markus Böl,et al.  Finite element modelling of rubber-like polymers based on chain statistics , 2006 .

[24]  Paul Steinmann,et al.  Hyperelastic models for rubber-like materials: consistent tangent operators and suitability for Treloar’s data , 2012 .

[25]  Franck Nicoud,et al.  BIOMECHANICAL ASSESSMENT OF THE INDIVIDUAL RISK OF RUPTURE OF INTRACRANIAL CEREBRAL ANEURYSMS: A PROOF OF CONCEPT , 2012 .

[26]  M. Mooney A Theory of Large Elastic Deformation , 1940 .

[27]  R. Ogden Non-Linear Elastic Deformations , 1984 .

[28]  K. An,et al.  Extensor mechanism of the fingers. I. A quantitative geometric study. , 1991, The Journal of hand surgery.

[29]  G. Lourie,et al.  Boutonnière and pulley rupture in elite athletes. , 2012, Hand clinics.

[30]  Wing Kam Liu,et al.  Nonlinear Finite Elements for Continua and Structures , 2000 .

[31]  F. Nicoud,et al.  Biomechanical Assessment of the Individual Risk of Rupture of Cerebral Aneurysms: A Proof of Concept , 2012, Annals of Biomedical Engineering.

[32]  Tao Cheng,et al.  Mechanical properties of anterior malleolar ligament from experimental measurement and material modeling analysis , 2008, Biomechanics and modeling in mechanobiology.

[33]  Kumar Vemaganti,et al.  A Bayesian approach to selecting hyperelastic constitutive models of soft tissue , 2015 .

[34]  S Micera,et al.  A novel microstructural approach in tendon viscoelastic modelling at the fibrillar level. , 2006, Journal of biomechanics.

[35]  Ivonne Sgura,et al.  Fitting hyperelastic models to experimental data , 2004 .

[36]  Narayan K. Sundaram,et al.  Conventional radiographic evaluation of athletic injuries to the hand. , 2013, Radiologic clinics of North America.

[37]  Xiangming Zhang,et al.  Experimental measurement and modeling analysis on mechanical properties of incudostapedial joint , 2011, Biomechanics and modeling in mechanobiology.

[38]  A. Rettig,et al.  Athletic Injuries of the Wrist and Hand , 2003, The American journal of sports medicine.

[39]  M. Ahmadian,et al.  Investigation of the effect of high +Gz accelerations on human cardiac function. , 2013, Journal of the mechanical behavior of biomedical materials.

[40]  W. Souter The problem of boutonniere deformity. , 1974, Clinical orthopaedics and related research.

[41]  Tom Shearer,et al.  A new strain energy function for the hyperelastic modelling of ligaments and tendons based on fascicle microstructure. , 2015, Journal of biomechanics.