A wearable, self-calibrating, wireless sensor network for body motion processing

A novel self-calibrating sensing technology using miniature linear encoders and inertial/magnetic measurement unit (IMU) provides the accuracy, fast response and robustness required by many body motion processing applications. Our sensor unit consists of an accelerometer, a 3-axis magnetic sensor, 2 gyroscopes and a miniature linear encoder. The fusion of data from the sensors is accomplished by extracting the gravity related term from the accelerometer and consistently calibrating the gyroscopes and linear encoder when the sensor unit is under static conditions. Using the fused sensors, we developed a complete motion processing system that consists of a gateway where the human kinematics modeling is embedded. A time divided multiple access wireless architecture is adopted to synchronize the sensor network at 100 Hz. Experimental results show that the combination of the IMU and linear encoder produces a low RMS error of 3.5deg and correlation coefficient of 99.01%. A video showing the capture a performer's upper body motion is also realized.

[1]  H Harry Asada,et al.  Wearable Conductive Fiber Sensors for Multi-Axis Human Joint Angle Measurements , 2005, Journal of NeuroEngineering and Rehabilitation.

[2]  Lee A. Danisch,et al.  Spatially continuous six degree of freedom position and orientation sensor , 1999 .

[3]  Greg Welch,et al.  Motion Tracking: No Silver Bullet, but a Respectable Arsenal , 2002, IEEE Computer Graphics and Applications.

[4]  Lee A. Danisch,et al.  Spatially continuous six-degrees-of-freedom position and orientation sensor , 1999, Other Conferences.

[5]  D. Rossi,et al.  Wearable kinesthetic system for capturing and classifying upper limb gesture in post-stroke rehabilitation , 2005, First Joint Eurohaptics Conference and Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. World Haptics Conference.

[6]  J.A. Paradiso,et al.  A Compact, High-Speed, Wearable Sensor Network for Biomotion Capture and Interactive Media , 2007, 2007 6th International Symposium on Information Processing in Sensor Networks.

[7]  R. Wijesiriwardana,et al.  Inductive fiber-meshed strain and displacement transducers for respiratory measuring systems and motion capturing systems , 2006, IEEE Sensors Journal.

[8]  K. Aminian,et al.  Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement. , 2004, Gait & posture.