Uniform distribution of projection data for improved reconstruction quality of 4D EPR imaging.

In continuous wave (CW) electron paramagnetic resonance imaging (EPRI), high quality of reconstruction in a limited acquisition time is a high priority. It has been shown for the case of 3D EPRI, that a uniform distribution of the projection data generally enhances reconstruction quality. In this work, we have suggested two data acquisition techniques for which the gradient orientations are more evenly distributed over the 4D acquisition space as compared to the existing methods. The first sampling technique is based on equal solid angle partitioning of 4D space, while the second technique is based on Fekete points estimation in 4D to generate a more uniform distribution of data. After acquisition, filtered backprojection (FBP) is applied to carry out the reconstruction in a single stage. The single-stage reconstruction improves the spatial resolution by eliminating the necessity of data interpolation in multi-stage reconstructions. For the proposed data distributions, the simulations and experimental results indicate a higher fidelity to the true object configuration. Using the uniform distribution, we expect about 50% reduction in the acquisition time over the traditional method of equal linear angle acquisition.

[1]  J. Zweier,et al.  Development and optimization of three-dimensional spatial EPR imaging for biological organs and tissues. , 1995, Journal of magnetic resonance. Series B.

[2]  M N Yongbi,et al.  Critical oxygen tension in rat brain: a combined (31)P-NMR and EPR oximetry study. , 2000, American journal of physiology. Regulatory, integrative and comparative physiology.

[3]  J. Zweier,et al.  Mapping the spin-density and lineshape distribution of free radicals using 4D spectral-spatial EPR imaging. , 1995, Journal of magnetic resonance. Series B.

[4]  Gareth R. Eaton,et al.  Spectral-spatial two-dimensional EPR imaging , 1987 .

[5]  P. Gruber,et al.  Funktionen von beschränkter Variation in der Theorie der Gleichverteilung , 1990 .

[6]  D. M. Deaven,et al.  Genetic-algorithm energy minimization for point charges on a sphere. , 1996, Physical review. B, Condensed matter.

[7]  P C Lauterbur,et al.  A gradient control device for complete three-dimensional nuclear magnetic resonance zeugmatographic imaging , 1980 .

[8]  Sankaran Subramanian,et al.  Radiofrequency FT EPR Spectroscopy and Imaging , 1993 .

[9]  S. Deans The Radon Transform and Some of Its Applications , 1983 .

[10]  E. Saff,et al.  Distributing many points on a sphere , 1997 .

[11]  A. G. Every,et al.  Energies and spacings of point charges on a sphere , 1992 .

[12]  Steven B. Damelin,et al.  On point energies, separation radius and mesh norm for s-extremal configurations on compact sets in Rn , 2005, J. Complex..

[13]  P. Kuppusamy EPR spectroscopy in biology and medicine. , 2004, Antioxidants & redox signaling.

[14]  Gareth R Eaton,et al.  Comparison of maximum entropy and filtered back-projection methods to reconstruct rapid-scan EPR images. , 2007, Journal of magnetic resonance.

[15]  Marco Ferrari,et al.  Present status of electron paramagnetic resonance (EPR) spectroscopy/imaging for free radical detection , 1996, Pflügers Archiv.

[16]  Otfried Cheong,et al.  Voronoi diagrams on the spher , 2002, Comput. Geom..

[17]  J. Zweier,et al.  In vivo measurement of arterial and venous oxygenation in the rat using 3D spectral-spatial electron paramagnetic resonance imaging. , 1998, Physics in medicine and biology.

[18]  T. Erber,et al.  Equilibrium configurations of N equal charges on a sphere , 1991 .

[19]  Steven B. Damelin,et al.  Energy functionals, numerical integration and asymptotic equidistribution on the sphere , 2003, J. Complex..

[20]  R Milbradt,et al.  One- and two-dimensional electron paramagnetic resonance imaging in skin. , 1991, Free radical research communications.

[21]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[22]  E. Hlawka Funktionen von beschränkter Variatiou in der Theorie der Gleichverteilung , 1961 .

[23]  Peter Shirley,et al.  Discrepancy as a Quality Measure for Sample Distributions , 1991, Eurographics.

[24]  Shingo Matsumoto,et al.  Absolute oxygen tension (pO2) in murine fatty and muscle tissue as determined by EPR , 2005, Magnetic resonance in medicine.

[25]  E. Saff,et al.  Minimal Discrete Energy on the Sphere , 1994 .

[26]  G. Placidi,et al.  Theory of Adaptive Acquisition Method for Image Reconstruction from Projections and Application to EPR Imaging , 1995 .

[27]  Rizwan Ahmad,et al.  Quasi Monte Carlo-based isotropic distribution of gradient directions for improved reconstruction quality of 3D EPR imaging. , 2007, Journal of magnetic resonance.

[28]  Paul C. Lauterbur,et al.  Back projection reconstruction of spectroscopic NMR images from incomplete sets of projections , 1986 .

[29]  Neil J. A. Sloane,et al.  New Spherical 4-designs , 1992, Proceedings. IEEE International Symposium on Information Theory.

[30]  J. P. Jones,et al.  Foundations of Medical Imaging , 1993 .

[31]  Zhi-Pei Liang,et al.  Partial Radon transforms , 1997, IEEE Trans. Image Process..

[32]  David M. Grant,et al.  Methods for analyzing spectroscopic line shapes. NMR solid powder patterns , 1986 .

[33]  L. Berliner,et al.  One‐ and two‐dimensional EPR imaging studies on Phantoms and Plant specimens , 1985, Magnetic resonance in medicine.

[34]  Howard J Halpern,et al.  Spatially uniform sampling in 4-D EPR spectral-spatial imaging. , 2007, Journal of magnetic resonance.

[35]  Bak,et al.  REPULSION, A Novel Approach to Efficient Powder Averaging in Solid-State NMR , 1997, Journal of magnetic resonance.

[36]  Yuanmu Deng,et al.  Progressive EPR imaging with adaptive projection acquisition. , 2005, Journal of magnetic resonance.

[37]  Mehrdad Shahshahani,et al.  Distributing Points on the Sphere, I , 2003, Exp. Math..

[38]  Alexander Lubotzky,et al.  Distributing Points on the Sphere , 1994 .

[39]  Howard J Halpern,et al.  Imaging spin probe distribution in the tumor of a living mouse with 250 MHz EPR: Correlation with BOLD MRI , 2002, Magnetic resonance in medicine.

[40]  J. Hannay,et al.  Fibonacci numerical integration on a sphere , 2004 .