In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency.

Dynamic assessment of three-dimensional (3D) skeletal kinematics is essential for understanding normal joint function as well as the effects of injury or disease. This paper presents a novel technique for measuring in-vivo skeletal kinematics that combines data collected from high-speed biplane radiography and static computed tomography (CT). The goals of the present study were to demonstrate that highly precise measurements can be obtained during dynamic movement studies employing high frame-rate biplane video-radiography, to develop a method for expressing joint kinematics in an anatomically relevant coordinate system and to demonstrate the application of this technique by calculating canine tibio-femoral kinematics during dynamic motion. The method consists of four components: the generation and acquisition of high frame rate biplane radiographs, identification and 3D tracking of implanted bone markers, CT-based coordinate system determination, and kinematic analysis routines for determining joint motion in anatomically based coordinates. Results from dynamic tracking of markers inserted in a phantom object showed the system bias was insignificant (-0.02 mm). The average precision in tracking implanted markers in-vivo was 0.064 mm for the distance between markers and 0.31 degree for the angles between markers. Across-trial standard deviations for tibio-femoral translations were similar for all three motion directions, averaging 0.14 mm (range 0.08 to 0.20 mm). Variability in tibio-femoral rotations was more dependent on rotation axis, with across-trial standard deviations averaging 1.71 degrees for flexion/extension, 0.90 degree for internal/external rotation, and 0.40 degree for varus/valgus rotation. Advantages of this technique over traditional motion analysis methods include the elimination of skin motion artifacts, improved tracking precision and the ability to present results in a consistent anatomical reference frame.

[1]  Jean-Daniel Boissonnat,et al.  Three-dimensional reconstruction of complex shapes based on the Delaunay triangulation , 1993, Electronic Imaging.

[2]  T. Andriacchi,et al.  Interaction between active and passive knee stabilizers during level walking , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  M L Hull,et al.  Accuracy assessment of methods for determining hip movement in seated cycling. , 1995, Journal of biomechanics.

[4]  A Leardini,et al.  Position and orientation in space of bones during movement: experimental artefacts. , 1996, Clinical biomechanics.

[5]  G Selvik,et al.  Three-dimensional instability of the anterior cruciate deficient knee. , 1988, The Journal of bone and joint surgery. British volume.

[6]  B B Seedhom,et al.  Thickness of human articular cartilage in joints of the lower limb , 1999, Annals of the rheumatic diseases.

[7]  J Kärrholm,et al.  Roentgen stereophotogrammetry. Review of orthopedic applications. , 1989, Acta orthopaedica Scandinavica.

[8]  K. Markolf,et al.  The role of joint load in knee stability. , 1981, The Journal of bone and joint surgery. American volume.

[9]  A. J. van den Bogert,et al.  Effect of skin movement on the analysis of skeletal knee joint motion during running. , 1997, Journal of biomechanics.

[10]  H J Woltring,et al.  Planar control in multi-camera calibration for 3-D gait studies. , 1980, Journal of biomechanics.

[11]  Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods 1 , .

[12]  T P Andriacchi,et al.  Correcting for deformation in skin-based marker systems. , 2001, Journal of biomechanics.

[13]  G Selvik,et al.  Roentgen Stereophotogrammetric Analysis , 1990, Acta radiologica.

[14]  D J Schaeffer,et al.  Three-dimensional kinematics of the intact and cranial cruciate ligament-deficient stifle of dogs. , 1994, Journal of biomechanics.

[15]  S L Woo,et al.  A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data. , 2001, Journal of biomechanics.

[16]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[17]  Jayaram K. Udupa,et al.  A new in vivo technique for three-dimensional shoulder kinematics analysis , 1998, Skeletal Radiology.

[18]  P. Alberius Bone Reactions to Tantalum Markers , 1983 .

[19]  P R Cavanagh,et al.  Three-dimensional kinematics of the human knee during walking. , 1992, Journal of biomechanics.

[20]  M. A. Lafortune,et al.  Skin marker displacement at the knee joint , 1993 .

[21]  R. Johnson,et al.  The strain behavior of the anterior cruciate ligament during stair climbing: an in vivo study. , 1999, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[22]  Michael J. Flynn,et al.  Automated distortion correction of X-ray image intensifier images , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[23]  F E Zajac,et al.  Using cine phase contrast magnetic resonance imaging to non-invasively study in vivo knee dynamics. , 1997, Journal of biomechanics.

[24]  C. Spoor,et al.  Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.

[25]  U.D. Croce,et al.  Surface-marker cluster design criteria for 3-D bone movement reconstruction , 1997, IEEE Transactions on Biomedical Engineering.

[26]  T P Andriacchi,et al.  A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. , 1998, Journal of biomechanical engineering.

[27]  T. Kepple,et al.  Surface movement errors in shank kinematics and knee kinetics during gait , 1997 .